Phoenix 1200VA-5000VA inverters
  • Phoenix 1200VA-5000VA inverters

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: Victron energy

Phoenix 1200VA-5000VA inverters


Phoenix Inverter 24/5000


Phoenix Inverter Compact 24/1600

SinusMax - Superior engineering
Developed for professional duty, the Phoenix range of inverters is suitable for the widest range of applications. The design criteria have been to produce a true sinewave inverter with optimised efficiency but without compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact dimensions, light in weight and capable of supplyingpower, problem-free, to any load.

Extra start-up power
A unique feature of the SinusMax technology is very high start-up power. Conventional high frequency technology does not offer such extreme performance. Phoenix inverters, however, are well suited to power up difficult loads such as refrigeration compressors, electric motors and similar appliances.

Virtually unlimited power thanks to parallel and 3-phase operation capability
Up to 6 units inverters can operate in parallel to achieve higher power output. Six 24/5000 units, for example, will provide 24kW / 30kVA output power. Operation in 3-phase configuration is also possible. To transfer the load to another AC source: the automatic transfer switch If an automatic transfer switch is required we recommend using the MultiPlus inverter/charger instead. The switch is included in these products and the charger function of the MultiPlus can be disabled. Computers and other electronic equipment will continue to operate without disruption because the MultiPlus features a very short switchover time (less than 20 milliseconds).

Computer interface
All models have a RS-485 port. All you need to connect to your PC is our MK2 interface (see under accessories). This interface takes care of galvanic isolation between the inverter and the computer, and converts from RS-485 to RS-232. A RS-232 to USB conversion cable is also available. Together with our VEConfigure software, which can be downloaded free of charge from our website, all parameters of the inverters can be customised. This includes output voltage and frequency, over and undervoltage settings and programming the relay. This relay can for example be used to signal several alarm conditions, or to start a generator. The inverters can also be connected to VENet, the new power control network of Victron Energy, or to other computerised monitoring and control systems.

 



Inwerter Phoenix C12/1200
C24/1200
C48/1200
C12/1600
C24/1600
C48/1600
C12/2000
C24/2000
12/3000
24/3000
48/3000
  24/5000
48/5000
Parallel and 3-phase operation Yes
INWERTER
Input voltage range [V DC] 9,5 – 17V    19 – 33V    38 – 66V
Output 230 VAC ±2%      50 Hz ± 0,1% (1)
Cont. output power at 250C [VA] 1200 1600 2000 3000 5000
Cont. output power at 250C [W] 1000 1300 1600 2500 4500
Cont. output power at 400C [W] 900 1200 1450 2200 4000
Peak power [W] 2400 3000 4000 6000 10000
Max. efficiency 12/24/48 V [%] 92 / 94 92 / 94 92 / 92 93 / 94 / 95 94 / 95
Zero-load power 12/24/48 [W] 8 / 10 8 / 10 9 / 11 15 / 15 / 16 25 / 25
Zero-load power in AES mode [W] 5 / 8 5 / 8 7 / 9 10 / 10 / 12 20 / 20
Zero-load power in Search mode[W] 2 / 3 2 / 3 3 / 4 4 / 5 / 5 5 / 6
General
Programmable relay(3) Yes
Protection (4) a – g
VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
Remote on-off YES
Common Characteristics Operating temperature range: -40 to +50 ºC (fan assisted cooling)
Humidity (non condensing): max 95%
Enclosure
Common characteristics Material [&] Colour aluminium (blue RAL 5012)
Protection category: IP21
Battery-connection battery cables 1,5 meter included bolts M8 2+2 bolts M8
Connection 230V AC plug G-ST18i Spring-clamp Screw terminals
Weight [kg] 10 12 18 30
Dimensions [hxwhd in mm] 375x214x110 520x255x125 362x258x218 444x328x240
Standards
safety EN 60335-1
Emission immunity EN 55014-1 / EN 55014-2
  1. Can be adjusted to 60Hz and to 240V
  2. Non linear load, crest factor 3:1
  3. ) Programmable relay that can a.o. be set for
    general alarm, DC undervoltage or genset
    start/stop function.
    AC rating: 230V/4A
    DC rating: 4a up to 35VDC, 1A up to 60VDC
4) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) 230 V AC on inverter output
g) input voltage ripple too high

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in


Phoenix Inverter 24/5000


Phoenix Inverter Compact 24/1600

SinusMax - Superior engineering
Developed for professional duty, the Phoenix range of inverters is suitable for the widest range of applications. The design criteria have been to produce a true sinewave inverter with optimised efficiency but without compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact dimensions, light in weight and capable of supplyingpower, problem-free, to any load.

Extra start-up power
A unique feature of the SinusMax technology is very high start-up power. Conventional high frequency technology does not offer such extreme performance. Phoenix inverters, however, are well suited to power up difficult loads such as refrigeration compressors, electric motors and similar appliances.

Virtually unlimited power thanks to parallel and 3-phase operation capability
Up to 6 units inverters can operate in parallel to achieve higher power output. Six 24/5000 units, for example, will provide 24kW / 30kVA output power. Operation in 3-phase configuration is also possible. To transfer the load to another AC source: the automatic transfer switch If an automatic transfer switch is required we recommend using the MultiPlus inverter/charger instead. The switch is included in these products and the charger function of the MultiPlus can be disabled. Computers and other electronic equipment will continue to operate without disruption because the MultiPlus features a very short switchover time (less than 20 milliseconds).

Computer interface
All models have a RS-485 port. All you need to connect to your PC is our MK2 interface (see under accessories). This interface takes care of galvanic isolation between the inverter and the computer, and converts from RS-485 to RS-232. A RS-232 to USB conversion cable is also available. Together with our VEConfigure software, which can be downloaded free of charge from our website, all parameters of the inverters can be customised. This includes output voltage and frequency, over and undervoltage settings and programming the relay. This relay can for example be used to signal several alarm conditions, or to start a generator. The inverters can also be connected to VENet, the new power control network of Victron Energy, or to other computerised monitoring and control systems.

 



Inwerter Phoenix C12/1200
C24/1200
C48/1200
C12/1600
C24/1600
C48/1600
C12/2000
C24/2000
12/3000
24/3000
48/3000
  24/5000
48/5000
Parallel and 3-phase operation Yes
INWERTER
Input voltage range [V DC] 9,5 – 17V    19 – 33V    38 – 66V
Output 230 VAC ±2%      50 Hz ± 0,1% (1)
Cont. output power at 250C [VA] 1200 1600 2000 3000 5000
Cont. output power at 250C [W] 1000 1300 1600 2500 4500
Cont. output power at 400C [W] 900 1200 1450 2200 4000
Peak power [W] 2400 3000 4000 6000 10000
Max. efficiency 12/24/48 V [%] 92 / 94 92 / 94 92 / 92 93 / 94 / 95 94 / 95
Zero-load power 12/24/48 [W] 8 / 10 8 / 10 9 / 11 15 / 15 / 16 25 / 25
Zero-load power in AES mode [W] 5 / 8 5 / 8 7 / 9 10 / 10 / 12 20 / 20
Zero-load power in Search mode[W] 2 / 3 2 / 3 3 / 4 4 / 5 / 5 5 / 6
General
Programmable relay(3) Yes
Protection (4) a – g
VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
Remote on-off YES
Common Characteristics Operating temperature range: -40 to +50 ºC (fan assisted cooling)
Humidity (non condensing): max 95%
Enclosure
Common characteristics Material [&] Colour aluminium (blue RAL 5012)
Protection category: IP21
Battery-connection battery cables 1,5 meter included bolts M8 2+2 bolts M8
Connection 230V AC plug G-ST18i Spring-clamp Screw terminals
Weight [kg] 10 12 18 30
Dimensions [hxwhd in mm] 375x214x110 520x255x125 362x258x218 444x328x240
Standards
safety EN 60335-1
Emission immunity EN 55014-1 / EN 55014-2
  1. Can be adjusted to 60Hz and to 240V
  2. Non linear load, crest factor 3:1
  3. ) Programmable relay that can a.o. be set for
    general alarm, DC undervoltage or genset
    start/stop function.
    AC rating: 230V/4A
    DC rating: 4a up to 35VDC, 1A up to 60VDC
4) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) 230 V AC on inverter output
g) input voltage ripple too high
Comments (0)