-
BackX
-
Components
-
-
Category
-
Semiconductors
- Diodes
- Thyristors
-
Electro-insulated Modules
- Electro-insulated Modules | VISHAY (IR)
- Electro-insulated Modules | INFINEON (EUPEC)
- Electro-insulated Modules | Semikron
- Electro-insulated Modules | POWEREX
- Electro-insulated Modules | IXYS
- Electro-insulated Modules | POSEICO
- Electro-insulated Modules | ABB
- Electro-insulated Modules | TECHSEM
- Go to the subcategory
- Bridge Rectifiers
-
Transistors
- Transistors | GeneSiC
- SiC MOSFET Modules | Mitsubishi
- SiC MOSFET Modules | STARPOWER
- Module SiC MOSFET ABB’s
- IGBT Modules | MITSUBISHI
- Transistor Modules | MITSUBISHI
- MOSFET Modules | MITSUBISHI
- Transistor Modules | ABB
- IGBT Modules | POWEREX
- IGBT Modules | INFINEON (EUPEC)
- Silicon Carbide (SiC) semiconductor elements
- Go to the subcategory
- Gate Drivers
- Power Blocks
- Go to the subcategory
-
Electrical Transducers
-
Current Transducers | LEM
- Closed-Loop Current Transducers (C/L)
- Open-Loop Current Transducers (O/L)
- Current Transducers supplied with unipolar voltage
- 'Eta' Current Transducers
- Current Transducers - LF xx10 Series
- Current Transducers - LH Series
- Current Transducer - HOYL and HOYS Series
- Current Transducers - GO–SME & GO–SMS Series
- AUTOMOTIVE current transducers
- Go to the subcategory
-
Voltage Transducers | LEM
- Voltage Transducers - LV Series
- Voltage Transducers - DVL Series
- Precision Voltage Transducers with double magnetic core - CV Series
- Voltage Transducer for Traction - DV 4200/SP4
- Voltage Transducers - DVM Series
- Voltage Transducer - DVC 1000-P
- Voltage Transducers - DVC 1000 Series
- Go to the subcategory
- Precision Current Transducers | LEM
- Go to the subcategory
-
Current Transducers | LEM
-
Passive components (capacitors, resistors, fuses, filters)
- Resistors
-
Fuses
- Miniature Fuses for electronic circuits - ABC & AGC Series
- Tubular Fast-acting Fuses
- Time-delay Fuse Links with GL/GG & AM characteristics
- Ultrafast Fuse Links
- Fast-acting Fuses (British & American standard)
- Fast-acting Fuses (European standard)
- Traction Fuses
- High-voltage Fuse Links
- Go to the subcategory
- Capacitors
- EMI Filters
- Supercapacitors
- Power surge protection
- Go to the subcategory
-
Relays and Contactors
- Relays and Contactors - Theory
- 3-Phase AC Semiconductor Relays
- DC Semiconductor Relays
- Controllers, Control Systems and Accessories
- Soft Starters and Reversible Relays
- Electromechanical Relays
- Contactors
- Rotary Switches
-
Single-Phase AC Semiconductor Relays
- AC ONE PHASE RELAYS 1 series| D2425 | D2450
- One phase semiconductor AC relays CWA and CWD series
- One phase semiconductor AC relays CMRA and CMRD series
- One phase semiconductor AC relays - PS series
- Double and quadruple semiconductor AC relays - D24 D, TD24 Q, H12D48 D series
- One phase semiconductor relays - gn series
- Ckr series single phase solid state relays
- One phase AC semiconductor relays for DIN bus - ERDA I ERAA series
- 150A AC single phase relays
- Rail Mountable Solid State Relays With Integrated Heat Sink - ENDA, ERDA1 / ERAA1 series
- Go to the subcategory
- Single-Phase AC Semiconductor Relays for PCBs
- Interface Relays
- Go to the subcategory
- Cores and Other Inductive Components
- Heatsinks, Varistors, Thermal Protection
- Fans
- Air Conditioning, Accessories for Electrical Cabinets, Coolers
-
Batteries, Chargers, Buffer Power Supplies and Inverters
- Batteries, Chargers - Theoretical Description
- Modular Li-ion Battery Building Blocks, Custom Batteries, BMS
- Batteries
- Battery Chargers and Accessories
- Uninterruptible Power Supply and Buffer Power Supplies
- Inverters and Photovoltaic Equipments
- Energy storage
- Fuel cells
- Lithium-ion batteries
- Go to the subcategory
-
Automatics
- Futaba Drone Parts
- Limit Switches, Microswitches
- Sensors, Transducers
-
Infrared Thermometers (Pyrometers)
- IR-TE Series - Water-proof Palm-sized Radiation Thermometer
- IR-TA Series - Handheld Type Radiation Thermometer
- IR-H Series - Handheld Type Radiation Thermometer
- IR-BA Series - High-speed Compact Radiation Thermometer
- IR-FA Series - Fiber Optic Radiation Thermometer
- IR-BZ Series - Compact Infrared Thermometers
- Go to the subcategory
- Counters, Time Relays, Panel Meters
- Industrial Protection Devices
- Light and Sound Signalling
- Thermographic Camera
- LED Displays
- Control Equipments
-
Recorders
- Hybrid Recorders - AL3000 Series | CHINO
- Graphic Recorder - KR2000 Series | CHINO
- Ubiquitous Recorders - KR5000 Series | CHINO
- Palm-sized Temperature/Humidity Meters - HN-CH Series | CHINO
- Consumables for Recorders
- 71VR1 - Compact Paperless Recorder | M-SYSTEM
- Graphic Recorder - KR3000 Series | CHINO
- PC Recorders - R1M Series | M-SYSTEM
- PC Recorders - R2M Series | M-SYSTEM
- PC Recorders - RZMS Series | M-SYSTEM
- PC Recorders - RZUS Series | M-SYSTEM
- Go to the subcategory
- Go to the subcategory
-
Cables, Litz wires, Conduits, Flexible connections
- Wires
- Litz wires
- Cables for extreme applications
- Sleevings
-
Braids
- Flat Braids
- Round Braids
- Very Flexible Flat Braids
- Very Flexible Round Braids
- Cylindrical Cooper Braids
- Cylindrical Cooper Braids and Sleevings
- Flexible Earthing Connections
- Galvanized and Stainless Steel Cylindrical Braids
- PCV Insulated Copper Braids (temp. up to 85C)
- Flat Aluminium Braids
- Junction Set - Braids and Tubes
- Go to the subcategory
- Traction Equipment
- Cable Terminals
- Flexible Insulated Busbars
- Flexible Multilayer Busbars
- Cable Duct Systems
- Hoses
- Go to the subcategory
- View all categories
-
Semiconductors
-
-
- Suppliers
-
Applications
- CNC Machine Tools
- DC and AC Drives (Inverters)
- Energetics
- Energy bank
- Equipment and Components for Hazardous Areas [Ex]
- Equipment for Distribution, Control and Telecommunications Cabinets
- HVAC Automation
- Induction Heating
- Industrial Automation
- Industrial Protective Devices
- Machines for Drying and Wood Processing
- Machines for Thermoforming Plastics
- Mining, Metallurgy and Foundry
- Motors and Transformers
- Power Supplies (UPS) and Rectifier Systems
- Printing
- Temperature Measurement and Regulation
- Test and Laboratory Measurements
- Tram and Railway Traction
- Welding Machines
-
Assembly
-
-
Montaż urządzeń
- Assembly of equipment on request
- Designing and Assembling of Busbar Cabinets, Switching Cabinets, Power Cabinets
- Power systems installation
- Components
- Machines built for order
- R&D research and development work
-
Industrial Testers
- Tester for diodes and thyristors measurement
- Thermal and motor circuit breakers testing stand
- Varistors and surge protectors testers
- Car fuses testing stand
- Tester for the power diode and thyristor reverse recovery charge Qrr measurement
- Rotor tester FD series
- Circuit breakers tester
- Tester for calibrating relays
- Video inspection tester for gas spring piston rods
- High-current thyristor switch
- Mesh ripping tester
- Go to the subcategory
- View all categories
-
-
-
Inductors
-
-
Modernizacja induktorów
- Repair of used inductors
- Modernization of inductors
-
Production of new inductors
- Inductors for crankshaft hardening
- Hardening of band saw teeth
- Inductors for heating elements before gluing
- Hardening of raceways of automotive wheel hub bearings
- Hardening of the drive transmission components
- Hardening of stepped shafts
- Heating in contraction joints
- Induction for scanning hardening
- Soft soldering
- Billet heaters
- Go to the subcategory
- Knowledge base
- View all categories
-
-
-
Induction devices
-
-
Urządzenia indukcyjne
-
Induction heating generators
-
Induction Heating Products Ambrell
- Generators power 500 W, frequency 150 - 400 kHz
- Generators power 1.2 - 2.4 kW, frequency 150 - 400 kHz
- Generators power 4.2 - 10 kW, frequency 150 - 400 kHz
- Generators power 10-15 kW, frequency 50-150 kHz
- Generators power 30-45 kW, frequency 50-150 kHz
- Generators power 65-135 kW, frequency 50-150 kHz
- Generators power 180-270 kW, frequency 50-150 kHz
- Generators power 20-35-50 kW, frequency 15-45 kHz
- Generators power 75-150 kW, frequency 15-45 kHz
- Generators power 200-500 kW, frequency 15-45 kHz
- Generators power 20-50 kW, frequency 5-15 kHz
- Go to the subcategory
- Induction heating products Denki Kogyo
-
JKZ induction heating generators
- Generators CX, frequency: 50-120kHz, power: 5-25kW
- Generators SWS, frequency: 15-30kHz, power: 25-260kW
- Molding and forging furnaces MFS, frequency: 0,5-10kHz, power: 80-500kW
- Melting metals furnaces MFS, frequency: 0,5-10kHz, power: 70-200kW
- Generators UHT, frequency: 200-400kHz, power: 10-160kW
- Go to the subcategory
- Lamp generators for induction heating
- Induction Heating Products - Himmelwerk
- Go to the subcategory
-
Induction Heating Products Ambrell
- Repairs and modernization
- Peripherals
-
Applications
- Medical Applications with Precision Induction Heating
- Applications for automotive industry
- Soldering
- Brazing
- Aluminum Brazing
- Brazing a magnetic steel cutting tool
- Pin Sealing
- Atmospheric Brazing
- Soldering brass and steel radiator caps
- Carbide Tipping
- Soldering a copper lug and a wire
- Go to the subcategory
- Knowledge base
- View all categories
-
Induction heating generators
-
-
-
Service
-
-
asd
- Service of industrial water coolers and air conditioners
- Machines Repairs and Modernizations
- Repair and Maintenance of Power Electronics, Electronic and Industrial Automation Devices
- HV Power Supplies for Electrostatic Precipitators
- Industrial Printers and Labelling Machines
- Certificates / Entitlements
- View all categories
-
-
- Contact
- Zobacz wszystkie kategorie
Photos are for informational purposes only. View product specification
please use latin characters
The Honeywell FF-SYA light curtain is in compliance with IEC/EN 61496 - parts 1 and 2 standard and meets the requirements for a Type 4 Active Optoelectronic Protective Device, the highest level for safety products. The product received an EC type test certificate from the French INRS notified body, required for safety equipment as per the 98/37/EC Machinery Directive. It meets the applicable parts of North American standards and regulations (OSHA 1910.212, OSHA 1910.217, ANSI standards including ANSI RIA 15.06 for Control Reliability and CSA Z434). Its CSA mark makes it a product usable in most parts of the world.
As soon as an object is detected inside the protection field, the FF-SYA de-energizes its two static safety outputs to signal the dangerous motion to stop. The FF-SYA is a self-contained light curtain that does not require a separate control unit for operation. Safety relay modules are available to provide higher current capability and additional functionality. This light curtain has been designed to satisfy the requirements of worldwide machine manufacturers and users: its compact size combined with its universal and smart features makes it full-featured and easy to use.
Features
• Active Optoelectronic Protective Device compliant with the requirements of the IEC/EN 61496 - parts 1 and 2 European norms for Type 4 electrosensitive protective equipment
• Meets applicable parts of North American standards and regulations OSHA 1910.212 and 217; ANSI B11.1.2 and .19; ANSI RIA 15.06 for Control Reliability; CSA standards
• Self-contained with optical synchronisation
• 2 static safety outputs with short-circuit and cross-fault detection
• Selection of the infrared emission power allows cross-talk reduction
• Enhanced diagnostic information includes: a signal strength indicator, a cross-talk indicator and a failure diagnostic indicator
• Test input with selectable test input type
• Resolutions available: ø14 mm / 0.6 in for finger detection ø30 mm / 1.2 in for hand detection ø60 mm / 2.4 in for leg detection
• Protection height up to 1830 mm / 72 in
• Scanning range up to 20 m / 65 ft
• Electrical connection:
- Hirschmann N6RFF type connectors,
- Brad Harrison Mini-Change® connectors
- Terminal strips
• Mounting brackets included allowing multiple mounting positions
• Safety relay modules for more switching capability or additional features (to be ordered separately).
Typical applications
• Presses and punches
• Metal-forming, milling and drilling machines
• Spot-welding machines and fine-boring machines
• Pressing, moulding and thermoforming machines
• Stacking machines, transporting and conveyor technology; handling equipment and assembly lines
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this product sheet (or catalogue) is for reference only. DO NOT USE this document as system
installation information.
• Complete installation, operation and maintenance information is to be referenced for each product.
Failure to comply with these instructions could result in death or serious injury.
- COMPACT SIZE
The cross section of 42 mm2 x 55 mm2 makes installation possible in tight spaces, especially with the help of the small brackets supplied with the light curtains. The available safety relay modules easily fit inside the machine control panel with its small width DIN rail mount housing.
- UNIVERSAL
The housing dimensions are the same for the 14 mm / 0.6 in, 30 mm / 1.2 in, 60 mm / 2.4 in resolution light curtains. The extended protected heights range from 334 mm to 1830 mm / 13.1 in to 72 in, covering industrial applications. The scanning range makes it possible to use mirrors in order to protect several sides of a machine with only one system.
- SMART
The FF-SYA is equipped with 2 static safety outputs. Compatible safety relay modules are available for a greater
output current capability and manual restart functionality. An integrated cross talk reduction system allows the scanning range to be selected for the application distance. A cross-talk indicator flickers when emission from other systems is detected, indicating that a different selection of the scanning range is needed. The light curtain also has a signal strength indicator which flickers if there is a slight misalignment of the beams or front window contamination. Additional indicators provide information on the outputs status, on the selected scanning range and on failure diagnostic. Standard brackets are delivered with the light curtain to ease the order process. The housing has a T-slot mounting system to adapt brackets anywhere along the lateral sides, the rear sides or at the top and
the bottom of the light curtain. Hirschmann connectors are delivered with the FF-SYA❏❏❏❏❏C2 light curtains.
Cross-talk reduction system
The FF-SYA light curtain is based upon an infrared transmission between an emitter unit and a receiver unit. It is a requirement of the IEC/EN 61496-2 standard that if a receiver R2 receives two signals transmitted by two different emitters E1 and E2, the receiver R2 must turn to the alarm state. This happens if the receiver R2 is within the beam aperture angle and within the nominal scanning range of the second emitter E1. The cross-talk detection indicator flickers on the receiver R2 to warn the installer.
An internal configuration card is available on the emitter units for the selection of the adequate emission power. This configuration card can be used to eliminate this cross-talk phenomenon by decreasing the maximum scanning range down to minimum. The end cap can be easily removed, and there is no need to remove the unit from the machinery to select a different scanning range. Products are delivered with a maximum scanning range to ease the alignment process.
Type | SYA14 | SYA30 | SYA60 |
---|---|---|---|
Resolutions mm/in | 0 14 /0,6 | 0 30 mm / 1.2 in | 0 60/2,4 |
Protection heights | Patrz tabela 2 | ||
Nominal scanning ranges (m/ft) | 0 - 6/0 - 20 | 0,3 - 18/1 - 60 | 0,3 - 18/0,3 - 60 |
Supply voltage | 24 V DC (± 15 %) | ||
Power consumption | Emitter: 5 W max. • Receiver: 7 W max. (see Table 2) | ||
Outputs | 2 PNP safety static outputs (switching capacity: 0,35 A / 24 Vdc) | ||
Response time | 13,5 to 22,5 ms (see Table 2) | ||
LED status indicators | Emitter: test mode, failure alarm, selected scanning range | ||
Cross sectional area | W 42 mm2 x D 55 mm2 / W 1.65 in2 x D 2.16 in2 | ||
Emission | Infrared modulated light source (880 nm) | ||
Effective aperture angle | ± 2°, ± 25 % (in compliance with the IEC/EN 61496 - Part 2) | ||
Light immunity | Sun: 20 000 lux • Lamp: 15 000 lux | ||
Electrical noise immunity | IEC 61000-4-4: level III / IEC 61000-4-3: level III | ||
Ambient temperature |
Operating temperature: 0 °C to 55 °C / 32 °F to 131 °F Storage temperature: -20 °C to 75 °C / -4 °F to 167 °F |
||
Vibrations | IEC/EN 61496-1: 10 to 55 Hz frequency range, 1 octave/min.sweep rate, | ||
Sealing | IP 65, NEMA 4, 13 | ||
Material | Housing: aluminium alloy • Front plate: polymethyl metacrylate (PMMA) • End caps: polycarbonate | ||
Electrical connection | FFF-SYA❏❏❏❏❏C2: EN 60423 plastic 7-pin right-angle plugs with crimping contacts |
Type | R (resolution) mm / in |
P (lens scale) mm / in |
D (lens diameter) mm / in |
A (non active zone) mm / in |
B (non active zone) mm / in |
---|---|---|---|---|---|
FF-SYA14 | 0 14/0,6 | 10/0,4 | 4/0,16 | 15,2/0,6 | 90,6/3,56 |
FF-SYA30 | 0 30/1,2 | 20 /0,8 | 10/0,4 | 22,27/0,7 | 86,8/3,45 |
FF-SYA60 | 0 60/ 2,4 | 40/1,6 | 10/0,4 | 42,2/1,66 | 87,6/3,45 |
Model | 032 | 048 | 064 | 080 | 096 | 112 | 128 | 144 | 160 | 176 |
---|---|---|---|---|---|---|---|---|---|---|
Protection height | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm |
SYA14 | 334 | 494 | 654 | 814 | 974 | 1134 | 1294 | - | - | - |
SYA30 | 350 | 510 | 670 | 830 | 990 | 1150 | 1310 | 1470 | 1630 | 1790 |
SYA60 | 390 | 550 | 710 | 870 | 1030 | 1190 | 1350 | 1510 | 1670 | 1830 |
Sensing field height | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm |
SYA14 | 314 | 474 | 634 | 794 | 954 | 1114 | 1274 | - | - | - |
SYA30 | 310 | 470 | 630 | 790 | 950 | 1110 | 1270 | 1430 | 1590 | 1750 |
SYA60 | 290 | 450 | 610 | 770 | 930 | 1090 | 1250 | 1410 | 1570 | 1730 |
Total height | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm |
FF-SYAC2 | 483 | 643 | 803 | 963 | 1123 | 1283 | 1443 | 1603 | 1763 | 1923 |
Response time | ms | ms | ms | ms | ms | ms | ms | ms | ms | ms |
SYA14 | 14 | 15 | 15,5 | 17,5 | 19,5 | 20,5 | 22,5 | - | - | - |
SYA30 | 13,5 | 14 | 14 | 14,5 | 15 | 15 | 15,5 | 16 | 17,5 | 17,5 |
SYA60 | 13,5 | 14 | 14 | 14,5 | 15 | 15 | 15,5 | 16 | 17,5 | 17,5 |
Weight per device11,381,762,142,522,93,283,664,044,42 | ||||||||||
SYA14 | 5/3,5 | 38111 | 38142 | 6/4,5 | 6/5 | 7/5 | 7/5,5 | - | - | - |
SYA30 | 4/3,5 | 4/3,5 | 38111 | 38111 | 5/4 | 6/4 | 6/4,5 | 6/4,5 | 6/4,5 | 6/4,5 |
SYA60 | 4/3,5 | 4/3,5 | 5/3,5 | 38111 | 5/4 | 6/4 | 6/4,5 | 6/4,5 | 6/4,5 | 6/4,5 |
Each listing consists of an emitter, a receiver,
2 pairs of right-angle brackets, a test rod and a
pair of Hirschmann N6RFF connector
1 - Resolutions
14: Ø 14mm 30: Ø 30mm 60: Ø 60mm 2 - Model: (see Table 2) 3 - C: DIN43651 plastic plugs included |
European EN 999 standard | SYA14 | SYA30 | SYA60 |
---|---|---|---|
Normal approach | |||
S≥ 2000 (t1 + t2),with S ≥ 100 If S ≥ 500, then use:S ≥ 1600 (t1 + t2),with S ≥ 500 | S ≥ 2000 (t1 + t2) + 128, with S ≥ 100 If S ≥ 500, then use:S ≥ 1600 (t1 + t2) + 128,with S ≥ 500 | S ≥ 1600 (t1 + t2) + 850,with Hu ≥ 900 HI ≤ 300 m | |
Parallel approach | |||
S ≥ 1600 (t1+ t2) + (1200 - 0.4 H), with H ≤ 875 or |
|||
Montaż Angled approach | |||
If α ≥ 30°, then use one of the formula given for a normal approach, with Hu ≥ 900 and Hl ≤ 300 for the FF-SYA60 light curtain If α ≤ 30°, then use one of the formula given for a parallel approach, with Hu ≤ 1000 and Hl ≥ 15 (R-50), where R is the light curtain resolution (with Hl ≥ 150 for the FF-SYA60 light curtain) |
With:
S: Minimum safety distance (in mm, 100 mm = 3.9 in)
t1: Light curtain response time (s)
t2: Machine stopping time (s)
H: Height of the detection plane above the reference floor (in mm)
Hu: Height of the uppermost beam above the reference floor (in mm)
Hl: Height of the lowest beam above the reference floor (in mm)
Send an inquiry
Are you interested in this product? Do you need additional information or individual pricing?
Contact us
The Honeywell FF-SYA light curtain is in compliance with IEC/EN 61496 - parts 1 and 2 standard and meets the requirements for a Type 4 Active Optoelectronic Protective Device, the highest level for safety products. The product received an EC type test certificate from the French INRS notified body, required for safety equipment as per the 98/37/EC Machinery Directive. It meets the applicable parts of North American standards and regulations (OSHA 1910.212, OSHA 1910.217, ANSI standards including ANSI RIA 15.06 for Control Reliability and CSA Z434). Its CSA mark makes it a product usable in most parts of the world.
As soon as an object is detected inside the protection field, the FF-SYA de-energizes its two static safety outputs to signal the dangerous motion to stop. The FF-SYA is a self-contained light curtain that does not require a separate control unit for operation. Safety relay modules are available to provide higher current capability and additional functionality. This light curtain has been designed to satisfy the requirements of worldwide machine manufacturers and users: its compact size combined with its universal and smart features makes it full-featured and easy to use.
Features
• Active Optoelectronic Protective Device compliant with the requirements of the IEC/EN 61496 - parts 1 and 2 European norms for Type 4 electrosensitive protective equipment
• Meets applicable parts of North American standards and regulations OSHA 1910.212 and 217; ANSI B11.1.2 and .19; ANSI RIA 15.06 for Control Reliability; CSA standards
• Self-contained with optical synchronisation
• 2 static safety outputs with short-circuit and cross-fault detection
• Selection of the infrared emission power allows cross-talk reduction
• Enhanced diagnostic information includes: a signal strength indicator, a cross-talk indicator and a failure diagnostic indicator
• Test input with selectable test input type
• Resolutions available: ø14 mm / 0.6 in for finger detection ø30 mm / 1.2 in for hand detection ø60 mm / 2.4 in for leg detection
• Protection height up to 1830 mm / 72 in
• Scanning range up to 20 m / 65 ft
• Electrical connection:
- Hirschmann N6RFF type connectors,
- Brad Harrison Mini-Change® connectors
- Terminal strips
• Mounting brackets included allowing multiple mounting positions
• Safety relay modules for more switching capability or additional features (to be ordered separately).
Typical applications
• Presses and punches
• Metal-forming, milling and drilling machines
• Spot-welding machines and fine-boring machines
• Pressing, moulding and thermoforming machines
• Stacking machines, transporting and conveyor technology; handling equipment and assembly lines
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this product sheet (or catalogue) is for reference only. DO NOT USE this document as system
installation information.
• Complete installation, operation and maintenance information is to be referenced for each product.
Failure to comply with these instructions could result in death or serious injury.
- COMPACT SIZE
The cross section of 42 mm2 x 55 mm2 makes installation possible in tight spaces, especially with the help of the small brackets supplied with the light curtains. The available safety relay modules easily fit inside the machine control panel with its small width DIN rail mount housing.
- UNIVERSAL
The housing dimensions are the same for the 14 mm / 0.6 in, 30 mm / 1.2 in, 60 mm / 2.4 in resolution light curtains. The extended protected heights range from 334 mm to 1830 mm / 13.1 in to 72 in, covering industrial applications. The scanning range makes it possible to use mirrors in order to protect several sides of a machine with only one system.
- SMART
The FF-SYA is equipped with 2 static safety outputs. Compatible safety relay modules are available for a greater
output current capability and manual restart functionality. An integrated cross talk reduction system allows the scanning range to be selected for the application distance. A cross-talk indicator flickers when emission from other systems is detected, indicating that a different selection of the scanning range is needed. The light curtain also has a signal strength indicator which flickers if there is a slight misalignment of the beams or front window contamination. Additional indicators provide information on the outputs status, on the selected scanning range and on failure diagnostic. Standard brackets are delivered with the light curtain to ease the order process. The housing has a T-slot mounting system to adapt brackets anywhere along the lateral sides, the rear sides or at the top and
the bottom of the light curtain. Hirschmann connectors are delivered with the FF-SYA❏❏❏❏❏C2 light curtains.
Cross-talk reduction system
The FF-SYA light curtain is based upon an infrared transmission between an emitter unit and a receiver unit. It is a requirement of the IEC/EN 61496-2 standard that if a receiver R2 receives two signals transmitted by two different emitters E1 and E2, the receiver R2 must turn to the alarm state. This happens if the receiver R2 is within the beam aperture angle and within the nominal scanning range of the second emitter E1. The cross-talk detection indicator flickers on the receiver R2 to warn the installer.
An internal configuration card is available on the emitter units for the selection of the adequate emission power. This configuration card can be used to eliminate this cross-talk phenomenon by decreasing the maximum scanning range down to minimum. The end cap can be easily removed, and there is no need to remove the unit from the machinery to select a different scanning range. Products are delivered with a maximum scanning range to ease the alignment process.
Type | SYA14 | SYA30 | SYA60 |
---|---|---|---|
Resolutions mm/in | 0 14 /0,6 | 0 30 mm / 1.2 in | 0 60/2,4 |
Protection heights | Patrz tabela 2 | ||
Nominal scanning ranges (m/ft) | 0 - 6/0 - 20 | 0,3 - 18/1 - 60 | 0,3 - 18/0,3 - 60 |
Supply voltage | 24 V DC (± 15 %) | ||
Power consumption | Emitter: 5 W max. • Receiver: 7 W max. (see Table 2) | ||
Outputs | 2 PNP safety static outputs (switching capacity: 0,35 A / 24 Vdc) | ||
Response time | 13,5 to 22,5 ms (see Table 2) | ||
LED status indicators | Emitter: test mode, failure alarm, selected scanning range | ||
Cross sectional area | W 42 mm2 x D 55 mm2 / W 1.65 in2 x D 2.16 in2 | ||
Emission | Infrared modulated light source (880 nm) | ||
Effective aperture angle | ± 2°, ± 25 % (in compliance with the IEC/EN 61496 - Part 2) | ||
Light immunity | Sun: 20 000 lux • Lamp: 15 000 lux | ||
Electrical noise immunity | IEC 61000-4-4: level III / IEC 61000-4-3: level III | ||
Ambient temperature |
Operating temperature: 0 °C to 55 °C / 32 °F to 131 °F Storage temperature: -20 °C to 75 °C / -4 °F to 167 °F |
||
Vibrations | IEC/EN 61496-1: 10 to 55 Hz frequency range, 1 octave/min.sweep rate, | ||
Sealing | IP 65, NEMA 4, 13 | ||
Material | Housing: aluminium alloy • Front plate: polymethyl metacrylate (PMMA) • End caps: polycarbonate | ||
Electrical connection | FFF-SYA❏❏❏❏❏C2: EN 60423 plastic 7-pin right-angle plugs with crimping contacts |
Type | R (resolution) mm / in |
P (lens scale) mm / in |
D (lens diameter) mm / in |
A (non active zone) mm / in |
B (non active zone) mm / in |
---|---|---|---|---|---|
FF-SYA14 | 0 14/0,6 | 10/0,4 | 4/0,16 | 15,2/0,6 | 90,6/3,56 |
FF-SYA30 | 0 30/1,2 | 20 /0,8 | 10/0,4 | 22,27/0,7 | 86,8/3,45 |
FF-SYA60 | 0 60/ 2,4 | 40/1,6 | 10/0,4 | 42,2/1,66 | 87,6/3,45 |
Model | 032 | 048 | 064 | 080 | 096 | 112 | 128 | 144 | 160 | 176 |
---|---|---|---|---|---|---|---|---|---|---|
Protection height | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm |
SYA14 | 334 | 494 | 654 | 814 | 974 | 1134 | 1294 | - | - | - |
SYA30 | 350 | 510 | 670 | 830 | 990 | 1150 | 1310 | 1470 | 1630 | 1790 |
SYA60 | 390 | 550 | 710 | 870 | 1030 | 1190 | 1350 | 1510 | 1670 | 1830 |
Sensing field height | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm |
SYA14 | 314 | 474 | 634 | 794 | 954 | 1114 | 1274 | - | - | - |
SYA30 | 310 | 470 | 630 | 790 | 950 | 1110 | 1270 | 1430 | 1590 | 1750 |
SYA60 | 290 | 450 | 610 | 770 | 930 | 1090 | 1250 | 1410 | 1570 | 1730 |
Total height | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm |
FF-SYAC2 | 483 | 643 | 803 | 963 | 1123 | 1283 | 1443 | 1603 | 1763 | 1923 |
Response time | ms | ms | ms | ms | ms | ms | ms | ms | ms | ms |
SYA14 | 14 | 15 | 15,5 | 17,5 | 19,5 | 20,5 | 22,5 | - | - | - |
SYA30 | 13,5 | 14 | 14 | 14,5 | 15 | 15 | 15,5 | 16 | 17,5 | 17,5 |
SYA60 | 13,5 | 14 | 14 | 14,5 | 15 | 15 | 15,5 | 16 | 17,5 | 17,5 |
Weight per device11,381,762,142,522,93,283,664,044,42 | ||||||||||
SYA14 | 5/3,5 | 38111 | 38142 | 6/4,5 | 6/5 | 7/5 | 7/5,5 | - | - | - |
SYA30 | 4/3,5 | 4/3,5 | 38111 | 38111 | 5/4 | 6/4 | 6/4,5 | 6/4,5 | 6/4,5 | 6/4,5 |
SYA60 | 4/3,5 | 4/3,5 | 5/3,5 | 38111 | 5/4 | 6/4 | 6/4,5 | 6/4,5 | 6/4,5 | 6/4,5 |
Each listing consists of an emitter, a receiver,
2 pairs of right-angle brackets, a test rod and a
pair of Hirschmann N6RFF connector
1 - Resolutions
14: Ø 14mm 30: Ø 30mm 60: Ø 60mm 2 - Model: (see Table 2) 3 - C: DIN43651 plastic plugs included |
European EN 999 standard | SYA14 | SYA30 | SYA60 |
---|---|---|---|
Normal approach | |||
S≥ 2000 (t1 + t2),with S ≥ 100 If S ≥ 500, then use:S ≥ 1600 (t1 + t2),with S ≥ 500 | S ≥ 2000 (t1 + t2) + 128, with S ≥ 100 If S ≥ 500, then use:S ≥ 1600 (t1 + t2) + 128,with S ≥ 500 | S ≥ 1600 (t1 + t2) + 850,with Hu ≥ 900 HI ≤ 300 m | |
Parallel approach | |||
S ≥ 1600 (t1+ t2) + (1200 - 0.4 H), with H ≤ 875 or |
|||
Montaż Angled approach | |||
If α ≥ 30°, then use one of the formula given for a normal approach, with Hu ≥ 900 and Hl ≤ 300 for the FF-SYA60 light curtain If α ≤ 30°, then use one of the formula given for a parallel approach, with Hu ≤ 1000 and Hl ≥ 15 (R-50), where R is the light curtain resolution (with Hl ≥ 150 for the FF-SYA60 light curtain) |
With:
S: Minimum safety distance (in mm, 100 mm = 3.9 in)
t1: Light curtain response time (s)
t2: Machine stopping time (s)
H: Height of the detection plane above the reference floor (in mm)
Hu: Height of the uppermost beam above the reference floor (in mm)
Hl: Height of the lowest beam above the reference floor (in mm)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent