Accuracy up to 0,05% High electric withstand of galvanic insulation (4kV). Universal input for one or two sensors. Function for signal proccess from two sensors(difference, average, record). Function THERMO-VOLTAGE SUPPRESSION for thermo voltage elimination. Function BREAK-PREVENTION for thermo cell breaking protection.
Supply voltage | 9 - 35 VDC |
Operation ambient temperatures: | -40 - 85C°C |
Reference temperature | 23 ± 5 °C |
Protection level: | execution H1x IP40, clamps IP00,after installation in head - head protection level |
execution L1x IP40, clamps IP20 | |
Humidity | execution H1 x 0 -100% with condensation after installation in head |
execution L1 x 0 -95% relative humidity without condensation | |
Cable connection: | screw clamps for section 0,5 - 1,5mm2, screw torque 0,5 Nm. |
Heating time: | 10s |
Bus type DIN: | TS 35 according to DIN 46277 |
Dimensions (H.xW.xL.) | H1 44 x 23,5 mm L1 x 90 x 18 x 59 mm (see dimensions drawings) |
Casing material: | H1x polycarbonate |
L1x polycarbonate | |
Weight: | H1x40gL1x80g |
Operation position: | arbitrary |
Are you interested in this product? Do you need additional information or individual pricing?
Accuracy up to 0,05% High electric withstand of galvanic insulation (4kV). Universal input for one or two sensors. Function for signal proccess from two sensors(difference, average, record). Function THERMO-VOLTAGE SUPPRESSION for thermo voltage elimination. Function BREAK-PREVENTION for thermo cell breaking protection.
Supply voltage | 9 - 35 VDC |
Operation ambient temperatures: | -40 - 85C°C |
Reference temperature | 23 ± 5 °C |
Protection level: | execution H1x IP40, clamps IP00,after installation in head - head protection level |
execution L1x IP40, clamps IP20 | |
Humidity | execution H1 x 0 -100% with condensation after installation in head |
execution L1 x 0 -95% relative humidity without condensation | |
Cable connection: | screw clamps for section 0,5 - 1,5mm2, screw torque 0,5 Nm. |
Heating time: | 10s |
Bus type DIN: | TS 35 according to DIN 46277 |
Dimensions (H.xW.xL.) | H1 44 x 23,5 mm L1 x 90 x 18 x 59 mm (see dimensions drawings) |
Casing material: | H1x polycarbonate |
L1x polycarbonate | |
Weight: | H1x40gL1x80g |
Operation position: | arbitrary |