-
BackX
-
Components
-
-
Category
-
Semiconductors
- Diodes
- Thyristors
-
Electro-insulated Modules
- Electro-insulated Modules | VISHAY (IR)
- Electro-insulated Modules | INFINEON (EUPEC)
- Electro-insulated Modules | Semikron
- Electro-insulated Modules | POWEREX
- Electro-insulated Modules | IXYS
- Electro-insulated Modules | POSEICO
- Electro-insulated Modules | ABB
- Electro-insulated Modules | TECHSEM
- Go to the subcategory
- Bridge Rectifiers
-
Transistors
- Transistors | GeneSiC
- SiC MOSFET Modules | Mitsubishi
- SiC MOSFET Modules | STARPOWER
- Module SiC MOSFET ABB’s
- IGBT Modules | MITSUBISHI
- Transistor Modules | MITSUBISHI
- MOSFET Modules | MITSUBISHI
- Transistor Modules | ABB
- IGBT Modules | POWEREX
- IGBT Modules | INFINEON (EUPEC)
- Silicon Carbide (SiC) semiconductor elements
- Go to the subcategory
- Gate Drivers
- Power Blocks
- Go to the subcategory
-
Electrical Transducers
-
Current Transducers | LEM
- Closed-Loop Current Transducers (C/L)
- Open-Loop Current Transducers (O/L)
- Current Transducers supplied with unipolar voltage
- 'Eta' Current Transducers
- Current Transducers - LF xx10 Series
- Current Transducers - LH Series
- Current Transducer - HOYL and HOYS Series
- Current Transducers - GO–SME & GO–SMS Series
- AUTOMOTIVE current transducers
- Go to the subcategory
-
Voltage Transducers | LEM
- Voltage Transducers - LV Series
- Voltage Transducers - DVL Series
- Precision Voltage Transducers with double magnetic core - CV Series
- Voltage Transducer for Traction - DV 4200/SP4
- Voltage Transducers - DVM Series
- Voltage Transducer - DVC 1000-P
- Voltage Transducers - DVC 1000 Series
- Go to the subcategory
- Precision Current Transducers | LEM
- Go to the subcategory
-
Current Transducers | LEM
-
Passive components (capacitors, resistors, fuses, filters)
- Resistors
-
Fuses
- Miniature Fuses for electronic circuits - ABC & AGC Series
- Tubular Fast-acting Fuses
- Time-delay Fuse Links with GL/GG & AM characteristics
- Ultrafast Fuse Links
- Fast-acting Fuses (British & American standard)
- Fast-acting Fuses (European standard)
- Traction Fuses
- High-voltage Fuse Links
- Go to the subcategory
- Capacitors
- EMI Filters
- Supercapacitors
- Power surge protection
- Go to the subcategory
-
Relays and Contactors
- Relays and Contactors - Theory
- 3-Phase AC Semiconductor Relays
- DC Semiconductor Relays
- Controllers, Control Systems and Accessories
- Soft Starters and Reversible Relays
- Electromechanical Relays
- Contactors
- Rotary Switches
-
Single-Phase AC Semiconductor Relays
- AC ONE PHASE RELAYS 1 series| D2425 | D2450
- One phase semiconductor AC relays CWA and CWD series
- One phase semiconductor AC relays CMRA and CMRD series
- One phase semiconductor AC relays - PS series
- Double and quadruple semiconductor AC relays - D24 D, TD24 Q, H12D48 D series
- One phase semiconductor relays - gn series
- Ckr series single phase solid state relays
- One phase AC semiconductor relays for DIN bus - ERDA I ERAA series
- 150A AC single phase relays
- Rail Mountable Solid State Relays With Integrated Heat Sink - ENDA, ERDA1 / ERAA1 series
- Go to the subcategory
- Single-Phase AC Semiconductor Relays for PCBs
- Interface Relays
- Go to the subcategory
- Cores and Other Inductive Components
- Heatsinks, Varistors, Thermal Protection
- Fans
- Air Conditioning, Accessories for Electrical Cabinets, Coolers
-
Batteries, Chargers, Buffer Power Supplies and Inverters
- Batteries, Chargers - Theoretical Description
- Modular Li-ion Battery Building Blocks, Custom Batteries, BMS
- Batteries
- Battery Chargers and Accessories
- Uninterruptible Power Supply and Buffer Power Supplies
- Inverters and Photovoltaic Equipments
- Energy storage
- Fuel cells
- Lithium-ion batteries
- Go to the subcategory
-
Automatics
- Futaba Drone Parts
- Limit Switches, Microswitches
- Sensors, Transducers
-
Infrared Thermometers (Pyrometers)
- IR-TE Series - Water-proof Palm-sized Radiation Thermometer
- IR-TA Series - Handheld Type Radiation Thermometer
- IR-H Series - Handheld Type Radiation Thermometer
- IR-BA Series - High-speed Compact Radiation Thermometer
- IR-FA Series - Fiber Optic Radiation Thermometer
- IR-BZ Series - Compact Infrared Thermometers
- Go to the subcategory
- Counters, Time Relays, Panel Meters
- Industrial Protection Devices
- Light and Sound Signalling
- Thermographic Camera
- LED Displays
- Control Equipments
-
Recorders
- Hybrid Recorders - AL3000 Series | CHINO
- Graphic Recorder - KR2000 Series | CHINO
- Ubiquitous Recorders - KR5000 Series | CHINO
- Palm-sized Temperature/Humidity Meters - HN-CH Series | CHINO
- Consumables for Recorders
- 71VR1 - Compact Paperless Recorder | M-SYSTEM
- Graphic Recorder - KR3000 Series | CHINO
- PC Recorders - R1M Series | M-SYSTEM
- PC Recorders - R2M Series | M-SYSTEM
- PC Recorders - RZMS Series | M-SYSTEM
- PC Recorders - RZUS Series | M-SYSTEM
- Go to the subcategory
- Go to the subcategory
-
Cables, Litz wires, Conduits, Flexible connections
- Wires
- Litz wires
- Cables for extreme applications
- Sleevings
-
Braids
- Flat Braids
- Round Braids
- Very Flexible Flat Braids
- Very Flexible Round Braids
- Cylindrical Cooper Braids
- Cylindrical Cooper Braids and Sleevings
- Flexible Earthing Connections
- Galvanized and Stainless Steel Cylindrical Braids
- PCV Insulated Copper Braids (temp. up to 85C)
- Flat Aluminium Braids
- Junction Set - Braids and Tubes
- Go to the subcategory
- Traction Equipment
- Cable Terminals
- Flexible Insulated Busbars
- Flexible Multilayer Busbars
- Cable Duct Systems
- Hoses
- Go to the subcategory
- View all categories
-
Semiconductors
-
-
- Suppliers
-
Applications
- CNC Machine Tools
- DC and AC Drives (Inverters)
- Energetics
- Energy bank
- Equipment and Components for Hazardous Areas [Ex]
- Equipment for Distribution, Control and Telecommunications Cabinets
- HVAC Automation
- Induction Heating
- Industrial Automation
- Industrial Protective Devices
- Machines for Drying and Wood Processing
- Machines for Thermoforming Plastics
- Mining, Metallurgy and Foundry
- Motors and Transformers
- Power Supplies (UPS) and Rectifier Systems
- Printing
- Temperature Measurement and Regulation
- Test and Laboratory Measurements
- Tram and Railway Traction
- Welding Machines
-
Assembly
-
-
Montaż urządzeń
- Assembly of equipment on request
- Designing and Assembling of Busbar Cabinets, Switching Cabinets, Power Cabinets
- Power systems installation
- Components
- Machines built for order
- R&D research and development work
-
Industrial Testers
- Tester for diodes and thyristors measurement
- Thermal and motor circuit breakers testing stand
- Varistors and surge protectors testers
- Car fuses testing stand
- Tester for the power diode and thyristor reverse recovery charge Qrr measurement
- Rotor tester FD series
- Circuit breakers tester
- Tester for calibrating relays
- Video inspection tester for gas spring piston rods
- High-current thyristor switch
- Mesh ripping tester
- Go to the subcategory
- View all categories
-
-
-
Inductors
-
-
Modernizacja induktorów
- Repair of used inductors
- Modernization of inductors
-
Production of new inductors
- Inductors for crankshaft hardening
- Hardening of band saw teeth
- Inductors for heating elements before gluing
- Hardening of raceways of automotive wheel hub bearings
- Hardening of the drive transmission components
- Hardening of stepped shafts
- Heating in contraction joints
- Induction for scanning hardening
- Soft soldering
- Billet heaters
- Go to the subcategory
- Knowledge base
- View all categories
-
-
-
Induction devices
-
-
Urządzenia indukcyjne
-
Induction heating generators
-
Induction Heating Products Ambrell
- Generators power 500 W, frequency 150 - 400 kHz
- Generators power 1.2 - 2.4 kW, frequency 150 - 400 kHz
- Generators power 4.2 - 10 kW, frequency 150 - 400 kHz
- Generators power 10-15 kW, frequency 50-150 kHz
- Generators power 30-45 kW, frequency 50-150 kHz
- Generators power 65-135 kW, frequency 50-150 kHz
- Generators power 180-270 kW, frequency 50-150 kHz
- Generators power 20-35-50 kW, frequency 15-45 kHz
- Generators power 75-150 kW, frequency 15-45 kHz
- Generators power 200-500 kW, frequency 15-45 kHz
- Generators power 20-50 kW, frequency 5-15 kHz
- Go to the subcategory
- Induction heating products Denki Kogyo
-
JKZ induction heating generators
- Generators CX, frequency: 50-120kHz, power: 5-25kW
- Generators SWS, frequency: 15-30kHz, power: 25-260kW
- Molding and forging furnaces MFS, frequency: 0,5-10kHz, power: 80-500kW
- Melting metals furnaces MFS, frequency: 0,5-10kHz, power: 70-200kW
- Generators UHT, frequency: 200-400kHz, power: 10-160kW
- Go to the subcategory
- Lamp generators for induction heating
- Induction Heating Products - Himmelwerk
- Go to the subcategory
-
Induction Heating Products Ambrell
- Repairs and modernization
- Peripherals
-
Applications
- Medical Applications with Precision Induction Heating
- Applications for automotive industry
- Soldering
- Brazing
- Aluminum Brazing
- Brazing a magnetic steel cutting tool
- Pin Sealing
- Atmospheric Brazing
- Soldering brass and steel radiator caps
- Carbide Tipping
- Soldering a copper lug and a wire
- Go to the subcategory
- Knowledge base
- View all categories
-
Induction heating generators
-
-
-
Service
-
-
asd
- Service of industrial water coolers and air conditioners
- Machines Repairs and Modernizations
- Repair and Maintenance of Power Electronics, Electronic and Industrial Automation Devices
- HV Power Supplies for Electrostatic Precipitators
- Industrial Printers and Labelling Machines
- Certificates / Entitlements
- View all categories
-
-
- Contact
- Zobacz wszystkie kategorie
Photos are for informational purposes only. View product specification
please use latin characters
Accuracy class | 0.2 |
---|---|
Nominal voltage | 100-400V |
Nominal current | 1-5A |
Input range | 5-120% Un, In |
Calibration range | 50…120% Pn |
Response time | <200msec |
Response time | <0,5% p.p |
Continuous overload | 2 x In; 1.2 x Un |
Short-term overload | 20 x In; 2 x Un |
Operating frequency | 45…65Hz |
Current circuits consumption | < 0.5VA |
Voltage circuits consumption | < 0.5VA |
Aux. supply voltage | 80-260 Vac/dc |
Power | 6VA/6W |
Operating temperature | -10… 0 …+45… +50°C |
Storage temperature | -30…+70°C |
Self estinguishing thermoplastic material | UL 94V0 |
Galvanic insulation | Yes |
Test voltage | |
-p. supply/inputs/outputs -output/output |
4kV, 50Hz, 60sec. 700V, 50Hz, 60sec. |
Surge test | 5kV, 1.2/50 μsec. |
According to | EN 60688 |
TYPE | 1 output | 2 output | 3 output | 4 output |
---|---|---|---|---|
Monofase / Trifase |
MC2UP1 |
MC2UP2 |
MC2UP3 |
MC2UP4 |
RS485 MODBUS RTU + 1 PROG. PHOTO-MOS OUT |
+ | + | + | + |
DESCRIPTION
On-site fully programmablemulti-output transducer suitable for single phase or three-phase 3-4 wire balanced or unbalanced system. It is suitable also under distorted wave-forms conditions.The multi-output transducer permits to reduce strongly the installation complexity and the relevant costs and it permits to save a lot of space for fitting. Moreover the on-site complete programmability permits to use it for any measuring type requirement and, as a consequence, to semplify and to reduce either the supplies or availability of spare parts. On request it can be fitted with a RS485 serial interface plus Modbus protocol and with a programmable photo-mos output which can be set either as an alarm contact or as a pulse output for remote energy counting.
Aux .supply voltage | Standard | 80÷260Vac/dc (6VA/6W) |
On demand with extraprice | 20÷60Vac/dc (6VA/6W) |
ON-SITE FULLY PROGRAMMABILITY
These transducers are on-site fully programmable by using a standard USB interface and a remote simple configuration software.
The programmability includes the following function:
- Type (single or three phase, 3 or 4 wires, balanced or unbalanced load)
- Nominal value of inputs (voltage 57÷400V and current 1÷5A with automatic switching of the gains)
- Current and voltage transformer ratios
For each output (indipendent)
- Output type (V or mA)
- Rated output value.
Eg: 0…+/-1mA (15kΩ), 0…+/-5mA (3kΩ), 0…+/-10mA (1,5kΩ), 0…+/-20mA (750Ω),
4…20mA (750Ω); 0…+/-1V (>2kΩ); 0…+/-10V (>2kΩ), 2…10V (>2kΩ), etc) - Measure to be associated to the output, selected from among those available (See table).
- The start and full scale output values (eg. -25…0…100kW; 45…50…55Hz; 0.5C...1...0.5L; etc.)
For alarm output:
- Operating mode (minimum, maximum or a s watch-dog)
- Variable to be monitored
- Threshold level
- Operating delay
Or to retransmit the energy counting:
- Type of energy (active or reactive)
- Weight (eg 1 pulse = ... kWh)
For the serial interface
- Local address
- Communication parameters
ADDITIONAL MEASUREMENTS
In addition to the measurement of the main characteristics of the electricity grid, these transducers calculate and provide ery useful additional information, such as:
- The average current (thermal power)
- The maximum value reached by the thermal current The average current and the maximum value reached by the average current simulating the index black and the red of a bimetal ammeter.
- The average value of active power
- The peak (maximum value reached by the average active power)
- System voltage and current (average voltages and currents).
- Neutral current: obtained by the vector sum of phase currents (does not require an additional CT on the neutral conductor), indicating a poor distribution of loads on three phases and the presence of distorting loads.
- Target power factor: also called D.P.F. (Displacement power factor), indicates the real phase shift between voltage and current introduced by inductive or capacitive loads. The D.P.F. is different from the P.F. (Power factor). The P.F. value is affected by the harmonic distortion and could lead to P.F. corrections even in those cases where the P.F. value is lowered by harmonic distortions and not by unbalanced loads
- THD: Total harmonic distortion, shown as a percentage of the fundamental or RMS value. To prevent high levels of harmonic distortion, but at a very low consumption, would lead to unjustified alarmism, the total harmonic distortion can also be expressed as a percentage of nominal value, setting it in a more proper way.
Wiring diagram
TRMS
The measurement of the main variables (currents and voltages) is performed with the sampling method, which, in its own nature, permits the correct computation of the TRMS even in presence of distorted waveforms, which are more and more usual in modern electrical installations.
INSULATED OUTPUTS
All outputs in addition to the sefety insulation betweenthe measuring inputs and the auxiliary supply, are also insulated from each other: this helps to prevent or solve typical problems such as ground loops or plant masses at different potential between them.
DATA INTERFACE
On request a RS485 serial interface with Modbus RTU protocol is available for interfa-cing the transducers to supervision and energy management systems. on the same RS485 line is possible to wire up to 32 devices (128 with option ¼ unit load). The max line lenght shall be 1200 meters. A particular attention was paid to the optimization of the data transmission with the aim to get a complete picture of the system situation by means of very compact data packa-ges. Anyway it is always possible to choose which type of measurements have to be included in the data transmission.
ALARM OR PULSE OUTPUT
It is available (as option together with the RS485 interface) a photo-MOS programmable output that can be used as an alarm to monitor the operation of a specific measured quantity, or as a pulse for remote energy counting. It is possible to define the operation mode (minimum, maximum or as a watch-dog), the monitored variable, the set point and the delay. Alternatively, it is possible re-transmit the energy to remote units such as counting exter-nal pulses, PLC and so on. The pulse can be programmed directly, eg. 1 pulse = ... kWh, as well as the type of energy (active or reactive).
Send an inquiry
Are you interested in this product? Do you need additional information or individual pricing?
Contact us
Accuracy class | 0.2 |
---|---|
Nominal voltage | 100-400V |
Nominal current | 1-5A |
Input range | 5-120% Un, In |
Calibration range | 50…120% Pn |
Response time | <200msec |
Response time | <0,5% p.p |
Continuous overload | 2 x In; 1.2 x Un |
Short-term overload | 20 x In; 2 x Un |
Operating frequency | 45…65Hz |
Current circuits consumption | < 0.5VA |
Voltage circuits consumption | < 0.5VA |
Aux. supply voltage | 80-260 Vac/dc |
Power | 6VA/6W |
Operating temperature | -10… 0 …+45… +50°C |
Storage temperature | -30…+70°C |
Self estinguishing thermoplastic material | UL 94V0 |
Galvanic insulation | Yes |
Test voltage | |
-p. supply/inputs/outputs -output/output |
4kV, 50Hz, 60sec. 700V, 50Hz, 60sec. |
Surge test | 5kV, 1.2/50 μsec. |
According to | EN 60688 |
TYPE | 1 output | 2 output | 3 output | 4 output |
---|---|---|---|---|
Monofase / Trifase |
MC2UP1 |
MC2UP2 |
MC2UP3 |
MC2UP4 |
RS485 MODBUS RTU + 1 PROG. PHOTO-MOS OUT |
+ | + | + | + |
DESCRIPTION
On-site fully programmablemulti-output transducer suitable for single phase or three-phase 3-4 wire balanced or unbalanced system. It is suitable also under distorted wave-forms conditions.The multi-output transducer permits to reduce strongly the installation complexity and the relevant costs and it permits to save a lot of space for fitting. Moreover the on-site complete programmability permits to use it for any measuring type requirement and, as a consequence, to semplify and to reduce either the supplies or availability of spare parts. On request it can be fitted with a RS485 serial interface plus Modbus protocol and with a programmable photo-mos output which can be set either as an alarm contact or as a pulse output for remote energy counting.
Aux .supply voltage | Standard | 80÷260Vac/dc (6VA/6W) |
On demand with extraprice | 20÷60Vac/dc (6VA/6W) |
ON-SITE FULLY PROGRAMMABILITY
These transducers are on-site fully programmable by using a standard USB interface and a remote simple configuration software.
The programmability includes the following function:
- Type (single or three phase, 3 or 4 wires, balanced or unbalanced load)
- Nominal value of inputs (voltage 57÷400V and current 1÷5A with automatic switching of the gains)
- Current and voltage transformer ratios
For each output (indipendent)
- Output type (V or mA)
- Rated output value.
Eg: 0…+/-1mA (15kΩ), 0…+/-5mA (3kΩ), 0…+/-10mA (1,5kΩ), 0…+/-20mA (750Ω),
4…20mA (750Ω); 0…+/-1V (>2kΩ); 0…+/-10V (>2kΩ), 2…10V (>2kΩ), etc) - Measure to be associated to the output, selected from among those available (See table).
- The start and full scale output values (eg. -25…0…100kW; 45…50…55Hz; 0.5C...1...0.5L; etc.)
For alarm output:
- Operating mode (minimum, maximum or a s watch-dog)
- Variable to be monitored
- Threshold level
- Operating delay
Or to retransmit the energy counting:
- Type of energy (active or reactive)
- Weight (eg 1 pulse = ... kWh)
For the serial interface
- Local address
- Communication parameters
ADDITIONAL MEASUREMENTS
In addition to the measurement of the main characteristics of the electricity grid, these transducers calculate and provide ery useful additional information, such as:
- The average current (thermal power)
- The maximum value reached by the thermal current The average current and the maximum value reached by the average current simulating the index black and the red of a bimetal ammeter.
- The average value of active power
- The peak (maximum value reached by the average active power)
- System voltage and current (average voltages and currents).
- Neutral current: obtained by the vector sum of phase currents (does not require an additional CT on the neutral conductor), indicating a poor distribution of loads on three phases and the presence of distorting loads.
- Target power factor: also called D.P.F. (Displacement power factor), indicates the real phase shift between voltage and current introduced by inductive or capacitive loads. The D.P.F. is different from the P.F. (Power factor). The P.F. value is affected by the harmonic distortion and could lead to P.F. corrections even in those cases where the P.F. value is lowered by harmonic distortions and not by unbalanced loads
- THD: Total harmonic distortion, shown as a percentage of the fundamental or RMS value. To prevent high levels of harmonic distortion, but at a very low consumption, would lead to unjustified alarmism, the total harmonic distortion can also be expressed as a percentage of nominal value, setting it in a more proper way.
Wiring diagram
TRMS
The measurement of the main variables (currents and voltages) is performed with the sampling method, which, in its own nature, permits the correct computation of the TRMS even in presence of distorted waveforms, which are more and more usual in modern electrical installations.
INSULATED OUTPUTS
All outputs in addition to the sefety insulation betweenthe measuring inputs and the auxiliary supply, are also insulated from each other: this helps to prevent or solve typical problems such as ground loops or plant masses at different potential between them.
DATA INTERFACE
On request a RS485 serial interface with Modbus RTU protocol is available for interfa-cing the transducers to supervision and energy management systems. on the same RS485 line is possible to wire up to 32 devices (128 with option ¼ unit load). The max line lenght shall be 1200 meters. A particular attention was paid to the optimization of the data transmission with the aim to get a complete picture of the system situation by means of very compact data packa-ges. Anyway it is always possible to choose which type of measurements have to be included in the data transmission.
ALARM OR PULSE OUTPUT
It is available (as option together with the RS485 interface) a photo-MOS programmable output that can be used as an alarm to monitor the operation of a specific measured quantity, or as a pulse for remote energy counting. It is possible to define the operation mode (minimum, maximum or as a watch-dog), the monitored variable, the set point and the delay. Alternatively, it is possible re-transmit the energy to remote units such as counting exter-nal pulses, PLC and so on. The pulse can be programmed directly, eg. 1 pulse = ... kWh, as well as the type of energy (active or reactive).
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent