-
BackX
-
Components
-
-
Category
-
Semiconductors
- Diodes
- Thyristors
-
Electro-insulated Modules
- Electro-insulated Modules | VISHAY (IR)
- Electro-insulated Modules | INFINEON (EUPEC)
- Electro-insulated Modules | Semikron
- Electro-insulated Modules | POWEREX
- Electro-insulated Modules | IXYS
- Electro-insulated Modules | POSEICO
- Electro-insulated Modules | ABB
- Electro-insulated Modules | TECHSEM
- Go to the subcategory
- Bridge Rectifiers
-
Transistors
- Transistors | GeneSiC
- SiC MOSFET Modules | Mitsubishi
- SiC MOSFET Modules | STARPOWER
- Module SiC MOSFET ABB’s
- IGBT Modules | MITSUBISHI
- Transistor Modules | MITSUBISHI
- MOSFET Modules | MITSUBISHI
- Transistor Modules | ABB
- IGBT Modules | POWEREX
- IGBT Modules | INFINEON (EUPEC)
- Silicon Carbide (SiC) semiconductor elements
- Go to the subcategory
- Gate Drivers
- Power Blocks
- Go to the subcategory
-
Electrical Transducers
-
Current Transducers | LEM
- Closed-Loop Current Transducers (C/L)
- Open-Loop Current Transducers (O/L)
- Current Transducers supplied with unipolar voltage
- 'Eta' Current Transducers
- Current Transducers - LF xx10 Series
- Current Transducers - LH Series
- Current Transducer - HOYL and HOYS Series
- Current Transducers - GO–SME & GO–SMS Series
- AUTOMOTIVE current transducers
- Go to the subcategory
-
Voltage Transducers | LEM
- Voltage Transducers - LV Series
- Voltage Transducers - DVL Series
- Precision Voltage Transducers with double magnetic core - CV Series
- Voltage Transducer for Traction - DV 4200/SP4
- Voltage Transducers - DVM Series
- Voltage Transducer - DVC 1000-P
- Voltage Transducers - DVC 1000 Series
- Go to the subcategory
- Precision Current Transducers | LEM
- Go to the subcategory
-
Current Transducers | LEM
-
Passive components (capacitors, resistors, fuses, filters)
- Resistors
-
Fuses
- Miniature Fuses for electronic circuits - ABC & AGC Series
- Tubular Fast-acting Fuses
- Time-delay Fuse Links with GL/GG & AM characteristics
- Ultrafast Fuse Links
- Fast-acting Fuses (British & American standard)
- Fast-acting Fuses (European standard)
- Traction Fuses
- High-voltage Fuse Links
- Go to the subcategory
- Capacitors
- EMI Filters
- Supercapacitors
- Power surge protection
- Go to the subcategory
-
Relays and Contactors
- Relays and Contactors - Theory
- 3-Phase AC Semiconductor Relays
- DC Semiconductor Relays
- Controllers, Control Systems and Accessories
- Soft Starters and Reversible Relays
- Electromechanical Relays
- Contactors
- Rotary Switches
-
Single-Phase AC Semiconductor Relays
- AC ONE PHASE RELAYS 1 series| D2425 | D2450
- One phase semiconductor AC relays CWA and CWD series
- One phase semiconductor AC relays CMRA and CMRD series
- One phase semiconductor AC relays - PS series
- Double and quadruple semiconductor AC relays - D24 D, TD24 Q, H12D48 D series
- One phase semiconductor relays - gn series
- Ckr series single phase solid state relays
- One phase AC semiconductor relays for DIN bus - ERDA I ERAA series
- 150A AC single phase relays
- Rail Mountable Solid State Relays With Integrated Heat Sink - ENDA, ERDA1 / ERAA1 series
- Go to the subcategory
- Single-Phase AC Semiconductor Relays for PCBs
- Interface Relays
- Go to the subcategory
- Cores and Other Inductive Components
- Heatsinks, Varistors, Thermal Protection
- Fans
- Air Conditioning, Accessories for Electrical Cabinets, Coolers
-
Batteries, Chargers, Buffer Power Supplies and Inverters
- Batteries, Chargers - Theoretical Description
- Modular Li-ion Battery Building Blocks, Custom Batteries, BMS
- Batteries
- Battery Chargers and Accessories
- Uninterruptible Power Supply and Buffer Power Supplies
- Inverters and Photovoltaic Equipments
- Energy storage
- Fuel cells
- Lithium-ion batteries
- Go to the subcategory
-
Automatics
- Futaba Drone Parts
- Limit Switches, Microswitches
- Sensors, Transducers
-
Infrared Thermometers (Pyrometers)
- IR-TE Series - Water-proof Palm-sized Radiation Thermometer
- IR-TA Series - Handheld Type Radiation Thermometer
- IR-H Series - Handheld Type Radiation Thermometer
- IR-BA Series - High-speed Compact Radiation Thermometer
- IR-FA Series - Fiber Optic Radiation Thermometer
- IR-BZ Series - Compact Infrared Thermometers
- Go to the subcategory
- Counters, Time Relays, Panel Meters
- Industrial Protection Devices
- Light and Sound Signalling
- Thermographic Camera
- LED Displays
- Control Equipments
-
Recorders
- Hybrid Recorders - AL3000 Series | CHINO
- Graphic Recorder - KR2000 Series | CHINO
- Ubiquitous Recorders - KR5000 Series | CHINO
- Palm-sized Temperature/Humidity Meters - HN-CH Series | CHINO
- Consumables for Recorders
- 71VR1 - Compact Paperless Recorder | M-SYSTEM
- Graphic Recorder - KR3000 Series | CHINO
- PC Recorders - R1M Series | M-SYSTEM
- PC Recorders - R2M Series | M-SYSTEM
- PC Recorders - RZMS Series | M-SYSTEM
- PC Recorders - RZUS Series | M-SYSTEM
- Go to the subcategory
- Go to the subcategory
-
Cables, Litz wires, Conduits, Flexible connections
- Wires
- Litz wires
- Cables for extreme applications
- Sleevings
-
Braids
- Flat Braids
- Round Braids
- Very Flexible Flat Braids
- Very Flexible Round Braids
- Cylindrical Cooper Braids
- Cylindrical Cooper Braids and Sleevings
- Flexible Earthing Connections
- Galvanized and Stainless Steel Cylindrical Braids
- PCV Insulated Copper Braids (temp. up to 85C)
- Flat Aluminium Braids
- Junction Set - Braids and Tubes
- Go to the subcategory
- Traction Equipment
- Cable Terminals
- Flexible Insulated Busbars
- Flexible Multilayer Busbars
- Cable Duct Systems
- Hoses
- Go to the subcategory
- View all categories
-
Semiconductors
-
-
- Suppliers
-
Applications
- CNC Machine Tools
- DC and AC Drives (Inverters)
- Energetics
- Energy bank
- Equipment and Components for Hazardous Areas [Ex]
- Equipment for Distribution, Control and Telecommunications Cabinets
- HVAC Automation
- Induction Heating
- Industrial Automation
- Industrial Protective Devices
- Machines for Drying and Wood Processing
- Machines for Thermoforming Plastics
- Mining, Metallurgy and Foundry
- Motors and Transformers
- Power Supplies (UPS) and Rectifier Systems
- Printing
- Temperature Measurement and Regulation
- Test and Laboratory Measurements
- Tram and Railway Traction
- Welding Machines
-
Assembly
-
-
Montaż urządzeń
- Assembly of equipment on request
- Designing and Assembling of Busbar Cabinets, Switching Cabinets, Power Cabinets
- Power systems installation
- Components
- Machines built for order
- R&D research and development work
-
Industrial Testers
- Tester for diodes and thyristors measurement
- Thermal and motor circuit breakers testing stand
- Varistors and surge protectors testers
- Car fuses testing stand
- Tester for the power diode and thyristor reverse recovery charge Qrr measurement
- Rotor tester FD series
- Circuit breakers tester
- Tester for calibrating relays
- Video inspection tester for gas spring piston rods
- High-current thyristor switch
- Mesh ripping tester
- Go to the subcategory
- View all categories
-
-
-
Inductors
-
-
Modernizacja induktorów
- Repair of used inductors
- Modernization of inductors
-
Production of new inductors
- Inductors for crankshaft hardening
- Hardening of band saw teeth
- Inductors for heating elements before gluing
- Hardening of raceways of automotive wheel hub bearings
- Hardening of the drive transmission components
- Hardening of stepped shafts
- Heating in contraction joints
- Induction for scanning hardening
- Soft soldering
- Billet heaters
- Go to the subcategory
- Knowledge base
- View all categories
-
-
-
Induction devices
-
-
Urządzenia indukcyjne
-
Induction heating generators
-
Induction Heating Products Ambrell
- Generators power 500 W, frequency 150 - 400 kHz
- Generators power 1.2 - 2.4 kW, frequency 150 - 400 kHz
- Generators power 4.2 - 10 kW, frequency 150 - 400 kHz
- Generators power 10-15 kW, frequency 50-150 kHz
- Generators power 30-45 kW, frequency 50-150 kHz
- Generators power 65-135 kW, frequency 50-150 kHz
- Generators power 180-270 kW, frequency 50-150 kHz
- Generators power 20-35-50 kW, frequency 15-45 kHz
- Generators power 75-150 kW, frequency 15-45 kHz
- Generators power 200-500 kW, frequency 15-45 kHz
- Generators power 20-50 kW, frequency 5-15 kHz
- Go to the subcategory
- Induction heating products Denki Kogyo
-
JKZ induction heating generators
- Generators CX, frequency: 50-120kHz, power: 5-25kW
- Generators SWS, frequency: 15-30kHz, power: 25-260kW
- Molding and forging furnaces MFS, frequency: 0,5-10kHz, power: 80-500kW
- Melting metals furnaces MFS, frequency: 0,5-10kHz, power: 70-200kW
- Generators UHT, frequency: 200-400kHz, power: 10-160kW
- Go to the subcategory
- Lamp generators for induction heating
- Induction Heating Products - Himmelwerk
- Go to the subcategory
-
Induction Heating Products Ambrell
- Repairs and modernization
- Peripherals
-
Applications
- Medical Applications with Precision Induction Heating
- Applications for automotive industry
- Soldering
- Brazing
- Aluminum Brazing
- Brazing a magnetic steel cutting tool
- Pin Sealing
- Atmospheric Brazing
- Soldering brass and steel radiator caps
- Carbide Tipping
- Soldering a copper lug and a wire
- Go to the subcategory
- Knowledge base
- View all categories
-
Induction heating generators
-
-
-
Service
-
-
asd
- Service of industrial water coolers and air conditioners
- Machines Repairs and Modernizations
- Repair and Maintenance of Power Electronics, Electronic and Industrial Automation Devices
- HV Power Supplies for Electrostatic Precipitators
- Industrial Printers and Labelling Machines
- Certificates / Entitlements
- View all categories
-
-
- Contact
- Zobacz wszystkie kategorie
Photos are for informational purposes only. View product specification
please use latin characters
3kVA – 15kVA
Quattro 48/5000/70-100/100 | Quattro 24/3000/70-50/30 |
Two AC inputs with integrated transfer switch
The Quattro can be connected to two independent AC sources, for example the public grid and a generator, or two generators. The Quattro will automatically connect to the active source.
Two AC Outputs
The main output has no-break functionality. The Quattro Yeses over the supply to the connected loads in the event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge the battery, like a water heater for example, can be connected to this output.
Virtually unlimited power thanks to parallel operation
Up to 6 Quattro units can operate in parallel. Six units 48/10000/140, for example, will provide 54kW / 60kVA output power and 840 Amps charging capacity. .
Three phase capability
Three units can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel connected to provide 162kW / 180kVA inverter power and more than 2500A charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The Quattro is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side supply (16A per 5kVA Quattro at 230VAC). A current limit can be set on each AC input. The Quattro will then Yese account of other AC loads and use whatever is spare for charging, thus preventing the generator or mains supply from being overloaded.
PPowerAssist – Boosting shore or generator power
Ta cecha pozwala Quattrona chwilowe zwiększenie mocy wyjściowej. Tam, gdzie wysoka moc jest wymagana jedynie przez ograniczony czas, Quattro zapewni, że niewystarczająca moc źródła AC zostanie natychmiastowo uzupełniona przez energię z akumulatorów. Kiedy obciążenie się zmniejsza, dodatkowa moc jest zużywana na ładowanie baterii.
Czterostopniowa adaptacyjna ładowarka z dwoma wyjściami
This feature Yeses the principle of PowerControl to a further dimension allowing the Quattro to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the Quattro will make sure that insufficient mains or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems. Loss of mains detection software is available.
System configuring
- In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure.
- Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System Configurator software.
- Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
Solar Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Ve.Net Blue Power panel, Color Control panel, smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Victron Ethernet Remote, Victron Global Remote and the Color Control Panel. Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control panel can be accessed and settings can be change
Quattro | 12/3000/120-50/30 24/3000/70-50/30 |
12/5000/220-100/100 24/5000/120-100/100 48/5000/70-100/100 |
24/8000/200-100/100 48/8000/110-100/100 |
48/10000/140-100/100 |
---|---|---|---|---|
PowerControl / PowerAssist | Yes | |||
Integrated Transfer switch | Yes | |||
AC Input(x2) | Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz Power factor: 1 |
|||
Maximum feed through current [A] | 50/30 | 2x100 | 2x100 | 2x100 |
INWERTER | ||||
Input voltage range [V DC] |
9,5-17V 19-33V 38-66V | |||
Output (1) | Output voltage: 230V AC +-2% Frequency: 50Hz +-0,1% | |||
Cont. output power at 25oC [VA] (3) | 3000 | 5000 | 8000 | 10000 |
Cont. output power at 25oC [W] | 2500 | 4500 | 7000 | 9000 |
Cont. output power at 40oC [W] | 2200 | 4000 | 6300 | 8000 |
Peak power [W] | 6000 | 10000 | 16000 | 20000 |
Maximum efficiency [%] | 93 / 94 | 94 / 94 / 95 | 94 / 96 | 96 |
Zero load power [W] | 15 / 15 | 25 / 25 / 25 | 30 / 35 | 35 |
Zero load power in AES mode[W] | 10 / 10 | 20 / 20 / 20 | 25 / 30 | 30 |
Zero load power in Search mode[W] | 4 / 5 | 5 / 5 / 6 | 8 / 10 | 10 |
CHARGER | ||||
Charge voltage 'absorption' [V DC] |
14,4 / 28,8 | 14,4 / 28,8 / 57,6 | 28,8 / 57,6 | 57,6 |
Charge voltage ‘float’ [V DC] | 13,8 / 27,6 | 13,8 / 27,6 / 55,2 | 27,6 / 55,2 | 55,2 |
Storage mode [V DC] | 13,2 / 26,4 | 13,2 / 26,4 / 52,8 | 26,4 / 52,8 | 52,8 |
Charge cyrrent house battery[A] (4) | 120 / 70 | 220 / 120 / 70 | 200 / 110 | 140 |
Charge current starter battery [A] | 4 (only in 12V and i 24V) | |||
Battery temperature sensore | Yes | |||
GENERAL | ||||
Auxiliary output [A] (5) | 25 | 50 | 50 | 50 |
Programmable relay (6) | 1x | 3x | 3x | 3x |
Protection (2) | a – g | |||
VE.Bus communication port | For parallel and three phase operation, remote monitoring and system integration | |||
General purpose com. port | 1x | 2x | 2x | 2x |
Remote on-off | Yes | |||
Common Characteristics | Operating temp.: -40 to +65˚C Humidity (non-condensing): max. 95% | |||
ENCLOSURE | ||||
Common Characteristics | Material [&] Colour: aluminium (blue RAL 5012) Protection category: IP 21 | |||
Battery-connection | Four M8 bolts (2 plus and 2 minus connections) | |||
230V AC-connection |
Screw terminals 13 mm2(6 AWG) |
Bolts M6 | Bolts M6 | Bolts M6 |
Weight [kg] | 19 | 34/30/30 | 45/41 | 45 |
Dimensions (hxwxd in mm) | 362 x 258 x 218 | 470 x 350 x 280 444 x 328 x 240 444 x 328 x 240 |
470 x 350 x 280 | 470 x 350 x 280 |
STANDARDS | ||||
Safety | EN 60335-1, EN 60335-2-29 | |||
Emission, Immunity | EN55014-1, EN 55014-2, EN 61000-3-3, EN 61000-6-3, EN 61000-6-2, EN 61000-6-1 | |||
|
DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC |
Example symbols
QUA123020010
QUA125020000
QUA243020010
QUA245021011
QUA248020010
QUA485021010
QUA485021011
QUA488024000
QUA481030010
QUA483150000
Send an inquiry
Are you interested in this product? Do you need additional information or individual pricing?
Contact us
3kVA – 15kVA
Quattro 48/5000/70-100/100 | Quattro 24/3000/70-50/30 |
Two AC inputs with integrated transfer switch
The Quattro can be connected to two independent AC sources, for example the public grid and a generator, or two generators. The Quattro will automatically connect to the active source.
Two AC Outputs
The main output has no-break functionality. The Quattro Yeses over the supply to the connected loads in the event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge the battery, like a water heater for example, can be connected to this output.
Virtually unlimited power thanks to parallel operation
Up to 6 Quattro units can operate in parallel. Six units 48/10000/140, for example, will provide 54kW / 60kVA output power and 840 Amps charging capacity. .
Three phase capability
Three units can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel connected to provide 162kW / 180kVA inverter power and more than 2500A charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The Quattro is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side supply (16A per 5kVA Quattro at 230VAC). A current limit can be set on each AC input. The Quattro will then Yese account of other AC loads and use whatever is spare for charging, thus preventing the generator or mains supply from being overloaded.
PPowerAssist – Boosting shore or generator power
Ta cecha pozwala Quattrona chwilowe zwiększenie mocy wyjściowej. Tam, gdzie wysoka moc jest wymagana jedynie przez ograniczony czas, Quattro zapewni, że niewystarczająca moc źródła AC zostanie natychmiastowo uzupełniona przez energię z akumulatorów. Kiedy obciążenie się zmniejsza, dodatkowa moc jest zużywana na ładowanie baterii.
Czterostopniowa adaptacyjna ładowarka z dwoma wyjściami
This feature Yeses the principle of PowerControl to a further dimension allowing the Quattro to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the Quattro will make sure that insufficient mains or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems. Loss of mains detection software is available.
System configuring
- In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure.
- Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System Configurator software.
- Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
Solar Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Ve.Net Blue Power panel, Color Control panel, smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Victron Ethernet Remote, Victron Global Remote and the Color Control Panel. Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control panel can be accessed and settings can be change
Quattro | 12/3000/120-50/30 24/3000/70-50/30 |
12/5000/220-100/100 24/5000/120-100/100 48/5000/70-100/100 |
24/8000/200-100/100 48/8000/110-100/100 |
48/10000/140-100/100 |
---|---|---|---|---|
PowerControl / PowerAssist | Yes | |||
Integrated Transfer switch | Yes | |||
AC Input(x2) | Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz Power factor: 1 |
|||
Maximum feed through current [A] | 50/30 | 2x100 | 2x100 | 2x100 |
INWERTER | ||||
Input voltage range [V DC] |
9,5-17V 19-33V 38-66V | |||
Output (1) | Output voltage: 230V AC +-2% Frequency: 50Hz +-0,1% | |||
Cont. output power at 25oC [VA] (3) | 3000 | 5000 | 8000 | 10000 |
Cont. output power at 25oC [W] | 2500 | 4500 | 7000 | 9000 |
Cont. output power at 40oC [W] | 2200 | 4000 | 6300 | 8000 |
Peak power [W] | 6000 | 10000 | 16000 | 20000 |
Maximum efficiency [%] | 93 / 94 | 94 / 94 / 95 | 94 / 96 | 96 |
Zero load power [W] | 15 / 15 | 25 / 25 / 25 | 30 / 35 | 35 |
Zero load power in AES mode[W] | 10 / 10 | 20 / 20 / 20 | 25 / 30 | 30 |
Zero load power in Search mode[W] | 4 / 5 | 5 / 5 / 6 | 8 / 10 | 10 |
CHARGER | ||||
Charge voltage 'absorption' [V DC] |
14,4 / 28,8 | 14,4 / 28,8 / 57,6 | 28,8 / 57,6 | 57,6 |
Charge voltage ‘float’ [V DC] | 13,8 / 27,6 | 13,8 / 27,6 / 55,2 | 27,6 / 55,2 | 55,2 |
Storage mode [V DC] | 13,2 / 26,4 | 13,2 / 26,4 / 52,8 | 26,4 / 52,8 | 52,8 |
Charge cyrrent house battery[A] (4) | 120 / 70 | 220 / 120 / 70 | 200 / 110 | 140 |
Charge current starter battery [A] | 4 (only in 12V and i 24V) | |||
Battery temperature sensore | Yes | |||
GENERAL | ||||
Auxiliary output [A] (5) | 25 | 50 | 50 | 50 |
Programmable relay (6) | 1x | 3x | 3x | 3x |
Protection (2) | a – g | |||
VE.Bus communication port | For parallel and three phase operation, remote monitoring and system integration | |||
General purpose com. port | 1x | 2x | 2x | 2x |
Remote on-off | Yes | |||
Common Characteristics | Operating temp.: -40 to +65˚C Humidity (non-condensing): max. 95% | |||
ENCLOSURE | ||||
Common Characteristics | Material [&] Colour: aluminium (blue RAL 5012) Protection category: IP 21 | |||
Battery-connection | Four M8 bolts (2 plus and 2 minus connections) | |||
230V AC-connection |
Screw terminals 13 mm2(6 AWG) |
Bolts M6 | Bolts M6 | Bolts M6 |
Weight [kg] | 19 | 34/30/30 | 45/41 | 45 |
Dimensions (hxwxd in mm) | 362 x 258 x 218 | 470 x 350 x 280 444 x 328 x 240 444 x 328 x 240 |
470 x 350 x 280 | 470 x 350 x 280 |
STANDARDS | ||||
Safety | EN 60335-1, EN 60335-2-29 | |||
Emission, Immunity | EN55014-1, EN 55014-2, EN 61000-3-3, EN 61000-6-3, EN 61000-6-2, EN 61000-6-1 | |||
|
DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC |
Example symbols
QUA123020010
QUA125020000
QUA243020010
QUA245021011
QUA248020010
QUA485021010
QUA485021011
QUA488024000
QUA481030010
QUA483150000
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent