XTDB022 differential monitoring module
  • XTDB022 differential monitoring module

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: FRER

XTDB022 differential monitoring module

Residual direct current monitoring module (RDC-M-module)

 

Description:

The XTDB022 is a residual direct current monitoring module (RDC-M-module) which, electrically coupled to a protection unit (RCD relay) or switching unit (contactor, relay, etc.), performs the function of the residual direct current monitoring device (RDC-MD), in full compliance with the requirements of IEC 62955. It is used in AC charging stations permanently connected to the mains (mode 3 according to IEC 61851-1), where the presence of a residual direct current detecting device (RDC-DD), capable of interrupting the power supply to the electric vehicle (EV) in the event that this current is equal to or greater than 6 mA, is required in order to guarantee the correct operation of type A or type F RCD installed upstream of the station itself,
which could otherwise be “blinded” by the presence of an excessive direct current component. The XTDB022 monitoring module is characterized by a wide cable passing aperture (22.5 mm), while retaining a very small overall size, a JST connector for quick and easy installation, and a diagnostic LED that indicates the different operating states of the system.

   

power supply 12Vdc ±10% Typ 15mADC, max 25mADC
trip output active high, open collector, referred to GND
40V max (open) 0.1V, 100mA max (closed)
charging state input active low, referred to GND
low level < 1V
high level > 10V
nominal 24VDC
connector JST BH4B-XH-2
primary circuit rated load current 63A 3-phase or
single-phase 48...62Hz
nominal operating
residual current
nominal non-operating
6 mA
residual current 4 mA
response time < 9.5 s @ 6 mADC
< 250 ms @ 60 mADC
< 50 ms @ 200 mADC
operating temperature -25...+85°C
primary/secundary insulation 1500 V AC 5s, Uimp 4 kV (IEC 62955)
current surge withstanding 3 kA 8/20 us
protection degree IP40
self estinguishing
thermoplastic material
UL 94-V0



Ordering codes

Sensors

XTDB _ _ _ _ _ _

Current:

6mA DC

XTDB022006

 

10mA DC

XTDB022010

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Residual direct current monitoring module (RDC-M-module)

 

Description:

The XTDB022 is a residual direct current monitoring module (RDC-M-module) which, electrically coupled to a protection unit (RCD relay) or switching unit (contactor, relay, etc.), performs the function of the residual direct current monitoring device (RDC-MD), in full compliance with the requirements of IEC 62955. It is used in AC charging stations permanently connected to the mains (mode 3 according to IEC 61851-1), where the presence of a residual direct current detecting device (RDC-DD), capable of interrupting the power supply to the electric vehicle (EV) in the event that this current is equal to or greater than 6 mA, is required in order to guarantee the correct operation of type A or type F RCD installed upstream of the station itself,
which could otherwise be “blinded” by the presence of an excessive direct current component. The XTDB022 monitoring module is characterized by a wide cable passing aperture (22.5 mm), while retaining a very small overall size, a JST connector for quick and easy installation, and a diagnostic LED that indicates the different operating states of the system.

   

power supply 12Vdc ±10% Typ 15mADC, max 25mADC
trip output active high, open collector, referred to GND
40V max (open) 0.1V, 100mA max (closed)
charging state input active low, referred to GND
low level < 1V
high level > 10V
nominal 24VDC
connector JST BH4B-XH-2
primary circuit rated load current 63A 3-phase or
single-phase 48...62Hz
nominal operating
residual current
nominal non-operating
6 mA
residual current 4 mA
response time < 9.5 s @ 6 mADC
< 250 ms @ 60 mADC
< 50 ms @ 200 mADC
operating temperature -25...+85°C
primary/secundary insulation 1500 V AC 5s, Uimp 4 kV (IEC 62955)
current surge withstanding 3 kA 8/20 us
protection degree IP40
self estinguishing
thermoplastic material
UL 94-V0



Ordering codes

Sensors

XTDB _ _ _ _ _ _

Current:

6mA DC

XTDB022006

 

10mA DC

XTDB022010

Comments (0)