BackX
-
Components
-
-
Category
-
Semiconductors
- Diodes
- Thyristors
-
Electro-insulated Modules
- Electro-insulated Modules | VISHAY (IR)
- Electro-insulated Modules | INFINEON (EUPEC)
- Electro-insulated Modules | Semikron
- Electro-insulated Modules | POWEREX
- Electro-insulated Modules | IXYS
- Electro-insulated Modules | POSEICO
- Electro-insulated Modules | ABB
- Electro-insulated Modules | TECHSEM
- Go to the subcategory
- Bridge Rectifiers
-
Transistors
- Transistors | GeneSiC
- SiC MOSFET Modules | Mitsubishi
- SiC MOSFET Modules | STARPOWER
- Module SiC MOSFET ABB’s
- IGBT Modules | MITSUBISHI
- Transistor Modules | MITSUBISHI
- MOSFET Modules | MITSUBISHI
- Transistor Modules | ABB
- IGBT Modules | POWEREX
- IGBT Modules | INFINEON (EUPEC)
- Silicon Carbide (SiC) semiconductor elements
- Go to the subcategory
- Gate Drivers
- Power Blocks
- Go to the subcategory
-
Electrical Transducers
-
Current Transducers | LEM
- Closed-Loop Current Transducers (C/L)
- Open-Loop Current Transducers (O/L)
- Current Transducers supplied with unipolar voltage
- 'Eta' Current Transducers
- Current Transducers - LF xx10 Series
- Current Transducers - LH Series
- Current Transducer - HOYL and HOYS Series
- Current Transducers - GO–SME & GO–SMS Series
- AUTOMOTIVE current transducers
- Go to the subcategory
-
Voltage Transducers | LEM
- Voltage Transducers - LV Series
- Voltage Transducers - DVL Series
- Precision Voltage Transducers with double magnetic core - CV Series
- Voltage Transducer for Traction - DV 4200/SP4
- Voltage Transducers - DVM Series
- Voltage Transducer - DVC 1000-P
- Voltage Transducers - DVC 1000 Series
- Go to the subcategory
- Precision Current Transducers | LEM
- Go to the subcategory
-
Current Transducers | LEM
-
Passive components (capacitors, resistors, fuses, filters)
- Resistors
-
Fuses
- Miniature Fuses for electronic circuits - ABC & AGC Series
- Tubular Fast-acting Fuses
- Time-delay Fuse Links with GL/GG & AM characteristics
- Ultrafast Fuse Links
- Fast-acting Fuses (British & American standard)
- Fast-acting Fuses (European standard)
- Traction Fuses
- High-voltage Fuse Links
- Go to the subcategory
- Capacitors
- EMI Filters
- Supercapacitors
- Power surge protection
- Go to the subcategory
-
Relays and Contactors
- Relays and Contactors - Theory
- 3-Phase AC Semiconductor Relays
- DC Semiconductor Relays
- Controllers, Control Systems and Accessories
- Soft Starters and Reversible Relays
- Electromechanical Relays
- Contactors
- Rotary Switches
-
Single-Phase AC Semiconductor Relays
- AC ONE PHASE RELAYS 1 series| D2425 | D2450
- One phase semiconductor AC relays CWA and CWD series
- One phase semiconductor AC relays CMRA and CMRD series
- One phase semiconductor AC relays - PS series
- Double and quadruple semiconductor AC relays - D24 D, TD24 Q, H12D48 D series
- One phase semiconductor relays - gn series
- Ckr series single phase solid state relays
- One phase AC semiconductor relays for DIN bus - ERDA I ERAA series
- 150A AC single phase relays
- Rail Mountable Solid State Relays With Integrated Heat Sink - ENDA, ERDA1 / ERAA1 series
- Go to the subcategory
- Single-Phase AC Semiconductor Relays for PCBs
- Interface Relays
- Go to the subcategory
- Cores and Other Inductive Components
- Heatsinks, Varistors, Thermal Protection
- Fans
- Air Conditioning, Accessories for Electrical Cabinets, Coolers
-
Batteries, Chargers, Buffer Power Supplies and Inverters
- Batteries, Chargers - Theoretical Description
- Modular Li-ion Battery Building Blocks, Custom Batteries, BMS
- Batteries
- Battery Chargers and Accessories
- Uninterruptible Power Supply and Buffer Power Supplies
- Inverters and Photovoltaic Equipments
- Energy storage
- Fuel cells
- Lithium-ion batteries
- Go to the subcategory
-
Automatics
- Futaba Drone Parts
- Limit Switches, Microswitches
- Sensors, Transducers
-
Infrared Thermometers (Pyrometers)
- IR-TE Series - Water-proof Palm-sized Radiation Thermometer
- IR-TA Series - Handheld Type Radiation Thermometer
- IR-H Series - Handheld Type Radiation Thermometer
- IR-BA Series - High-speed Compact Radiation Thermometer
- IR-FA Series - Fiber Optic Radiation Thermometer
- IR-BZ Series - Compact Infrared Thermometers
- Go to the subcategory
- Counters, Time Relays, Panel Meters
- Industrial Protection Devices
- Light and Sound Signalling
- Thermographic Camera
- LED Displays
- Control Equipments
-
Recorders
- Hybrid Recorders - AL3000 Series | CHINO
- Graphic Recorder - KR2000 Series | CHINO
- Ubiquitous Recorders - KR5000 Series | CHINO
- Palm-sized Temperature/Humidity Meters - HN-CH Series | CHINO
- Consumables for Recorders
- 71VR1 - Compact Paperless Recorder | M-SYSTEM
- Graphic Recorder - KR3000 Series | CHINO
- PC Recorders - R1M Series | M-SYSTEM
- PC Recorders - R2M Series | M-SYSTEM
- PC Recorders - RZMS Series | M-SYSTEM
- PC Recorders - RZUS Series | M-SYSTEM
- Go to the subcategory
- Go to the subcategory
-
Cables, Litz wires, Conduits, Flexible connections
- Wires
- Litz wires
- Cables for extreme applications
- Sleevings
-
Braids
- Flat Braids
- Round Braids
- Very Flexible Flat Braids
- Very Flexible Round Braids
- Cylindrical Cooper Braids
- Cylindrical Cooper Braids and Sleevings
- Flexible Earthing Connections
- Galvanized and Stainless Steel Cylindrical Braids
- PCV Insulated Copper Braids (temp. up to 85C)
- Flat Aluminium Braids
- Junction Set - Braids and Tubes
- Go to the subcategory
- Traction Equipment
- Cable Terminals
- Flexible Insulated Busbars
- Flexible Multilayer Busbars
- Cable Duct Systems
- Hoses
- Go to the subcategory
- View all categories
-
Semiconductors
-
-
- Suppliers
-
Applications
- CNC Machine Tools
- DC and AC Drives (Inverters)
- Energetics
- Energy bank
- Equipment and Components for Hazardous Areas [Ex]
- Equipment for Distribution, Control and Telecommunications Cabinets
- HVAC Automation
- Induction Heating
- Industrial Automation
- Industrial Protective Devices
- Machines for Drying and Wood Processing
- Machines for Thermoforming Plastics
- Mining, Metallurgy and Foundry
- Motors and Transformers
- Power Supplies (UPS) and Rectifier Systems
- Printing
- Temperature Measurement and Regulation
- Test and Laboratory Measurements
- Tram and Railway Traction
- Welding Machines
-
Assembly
-
-
Montaż urządzeń
- Assembly of equipment on request
- Designing and Assembling of Busbar Cabinets, Switching Cabinets, Power Cabinets
- Power systems installation
- Components
- Machines built for order
- R&D research and development work
-
Industrial Testers
- Tester for diodes and thyristors measurement
- Thermal and motor circuit breakers testing stand
- Varistors and surge protectors testers
- Car fuses testing stand
- Tester for the power diode and thyristor reverse recovery charge Qrr measurement
- Rotor tester FD series
- Circuit breakers tester
- Tester for calibrating relays
- Video inspection tester for gas spring piston rods
- High-current thyristor switch
- Mesh ripping tester
- Go to the subcategory
- View all categories
-
-
-
Inductors
-
-
Modernizacja induktorów
- Repair of used inductors
- Modernization of inductors
-
Production of new inductors
- Inductors for crankshaft hardening
- Hardening of band saw teeth
- Inductors for heating elements before gluing
- Hardening of raceways of automotive wheel hub bearings
- Hardening of the drive transmission components
- Hardening of stepped shafts
- Heating in contraction joints
- Induction for scanning hardening
- Soft soldering
- Billet heaters
- Go to the subcategory
- Knowledge base
- View all categories
-
-
-
Induction devices
-
-
Urządzenia indukcyjne
-
Induction heating generators
-
Induction Heating Products Ambrell
- Generators power 500 W, frequency 150 - 400 kHz
- Generators power 1.2 - 2.4 kW, frequency 150 - 400 kHz
- Generators power 4.2 - 10 kW, frequency 150 - 400 kHz
- Generators power 10-15 kW, frequency 50-150 kHz
- Generators power 30-45 kW, frequency 50-150 kHz
- Generators power 65-135 kW, frequency 50-150 kHz
- Generators power 180-270 kW, frequency 50-150 kHz
- Generators power 20-35-50 kW, frequency 15-45 kHz
- Generators power 75-150 kW, frequency 15-45 kHz
- Generators power 200-500 kW, frequency 15-45 kHz
- Generators power 20-50 kW, frequency 5-15 kHz
- Go to the subcategory
- Induction heating products Denki Kogyo
-
JKZ induction heating generators
- Generators CX, frequency: 50-120kHz, power: 5-25kW
- Generators SWS, frequency: 15-30kHz, power: 25-260kW
- Molding and forging furnaces MFS, frequency: 0,5-10kHz, power: 80-500kW
- Melting metals furnaces MFS, frequency: 0,5-10kHz, power: 70-200kW
- Generators UHT, frequency: 200-400kHz, power: 10-160kW
- Go to the subcategory
- Lamp generators for induction heating
- Induction Heating Products - Himmelwerk
- Go to the subcategory
-
Induction Heating Products Ambrell
- Repairs and modernization
- Peripherals
-
Applications
- Medical Applications with Precision Induction Heating
- Applications for automotive industry
- Soldering
- Brazing
- Aluminum Brazing
- Brazing a magnetic steel cutting tool
- Pin Sealing
- Atmospheric Brazing
- Soldering brass and steel radiator caps
- Carbide Tipping
- Soldering a copper lug and a wire
- Go to the subcategory
- Knowledge base
- View all categories
-
Induction heating generators
-
-
-
Service
-
-
asd
- Service of industrial water coolers and air conditioners
- Machines Repairs and Modernizations
- Repair and Maintenance of Power Electronics, Electronic and Industrial Automation Devices
- HV Power Supplies for Electrostatic Precipitators
- Industrial Printers and Labelling Machines
- Certificates / Entitlements
- View all categories
-
-
- Contact
- Zobacz wszystkie kategorie
Photos are for informational purposes only. View product specification
please use latin characters
Safety relay - output extension 4004K/SNE 4004KV
Output expansion with relay for base devices in safety applications
• Stop category 0 and 1 according to EN 60204-1 (see “Notes”)
• Applications up to safety category 4 according to EN 954-1
(see “Notes”)
• Single-channel or two-channel control
• SNE 4004K: 4 enabling current paths, undelayed (NO contact)
3 signaling current paths, undelayed (NC contact)
• SNE 4004KV: 4 enabling current paths, OFF-delayed (NO contact)
3 signaling current paths, OFF-delayed (NC contact),
Time buffering
SNE 4004K
SNE 4004KV
SNE 4004K-A and SNE 4004KV-A
A1/A2 supply voltage Y1/Y2 feedback path 13/14,23/24,33/34,43/44, LED K1 ,LED K2 51/52 61/62 tA = response time tR2 = release time |
|
A1/A2 supply voltage Y1/Y2 feedback path 17/18,27/28,37/38,47/48, LED K1 ,LED K2 55/56,65/66 tA = response time tR1 = release time tM = minimum ON time |
The device can only be used as expansion device for safety switching devices.
• The stop and safety categories achieved by the SNE 4004K / KV always depend
on the categories of the base device. The category of the expansion device
cannot exceed that of the base device. By using the SNE 4004KV max.
category 3 according to EN 954-1 can be achieved.
• The expansion relays K1 and K2 are controlled via one or two enabling current
paths, depending on the required level of safety.
• The devices can be combined with all safety switching devices (base devices).
The feedback current path Y1/ Y2 must be wired to the reset or feedback loop of
the base device.
• The device and the contacts must be protected with max. 6 A utilization
category gG or through circuit breakers with trigger characteristic B or C.
• For connecting magnetic switches with reed contacts or sensors
with semiconductor outputs the peak input current must be considered
(see “Technical data”).
• The devices must be installed in a control cabinet with a protection degree
of at least IP 54.
SNE 4004K/KV | SNE 4004K-A/KV-A |
Technical data | SNE 4004K/SNE 4004KV | |
---|---|---|
Function according to EN 60204-1
|
Emergency stop expansion relay
|
|
Function display
|
2 LEDs green
|
|
Function diagram
|
FD 221-13-1 W, FD 221-13-2 W
|
|
Power supply circuit
|
min typ
|
max
|
Rated voltage UN SNE 4004K
|
AC/DC 20,4 V AC/DC 24 V
|
AC/DC 26,4 V
|
Rated voltage UN SNE 4004KV
|
DC 20,4 DC 24 V
|
DC 26,4 V
|
Rated consumption DC
|
1,0 W
|
|
Rated consumption AC
|
1,5 W/2,7 VA
|
|
Residual ripple DC
|
2,4 VSS
|
|
Rated frequency AC
|
50 Hz
|
60Hz
|
Rated current / peak current
|
65 mA/1000 mA
|
80 mA/1800 mA
|
Response time tA
|
20 ms
|
|
Release time tR2 SNE 4004K with emergency stop
|
40 ms
|
|
Minimum ON time tM SNE 4004KV
|
75 ms
|
|
Release time tR1 SNE 4004KV (buffered)
|
0,5 s/1 s/2 s/3 s
|
|
Mean value of the error SNE 4004KV
|
±20 %
|
|
Dispersion SNE 4004KV
|
±2 %
|
|
Feedback current path Y1/Y2
|
1 NC contact, positively driven
|
|
Rated switching voltage Un
|
DC 24 V
|
|
Max. continuous current In
|
0,1 A
|
|
Contact material
|
Ag alloy, gold-plated
|
|
Output circuits
|
||
Enabling current paths
|
4 NO contacts, positively driven
|
|
Rated switching voltage Un
|
AC/DC 230 V
|
|
Max. continuous current In/max. total current
|
6 A/12 A
|
|
Application category according to EN 60947-5-1 3600 h-1
360 h-1 |
AC-15: Ue 230 V, Ie 6 A / DC-13: Ue 24 V, Ie 3 A
DC-13: Ue 24 V, Ie 6 A |
|
Short-circuit protection, max. fuse insert
|
6 A class gG or circuit breaker with trigger characteristic B or C
|
|
Mechanical life
|
10x106
switching cycles
|
|
Contact material
|
Ag alloy, gold-plated
|
|
Contact material
|
2 NC contacts, positively driven
|
|
Rated operating voltage U
UN |
AC/DC 230 V
|
|
Max. continuous current In
|
2 A
|
|
Contact material
|
Ag alloy, gold-plated
|
|
General data
|
||
Creepage distances and clearances between the circuits
|
według EN 60664-1
|
|
Overvoltage category
|
III
|
|
Rated impulse voltage
|
4 kV
|
|
Rated voltage
|
AC 300 V
|
|
Degree of pollution of the device: inside / outside
|
2/3
|
|
Protection degree according to DIN EN 60529 (housing / terminals)
|
IP 40/IP 20
|
|
Ambient temperature / storage temperature
|
-25 - +55 °C/-25 - +75 °C
|
|
Dimension diagram
|
K 4-1 (screw terminals)/ K 4-2 (pluggable terminals)
|
|
Rated cross sections fine-stranded/solid
or fine-stranded with ferrules
|
2x0,14 - 0,75 mm2/1x0,14 - 2,5 mm2
1x0,25 - 2,5 mm2/2x0,25 - 0,5 mm2
|
|
Permissible tightening torque
|
0,5 – 0,6 Nm
|
|
Weight |
0,20 kg
|
|
Accessories
|
-
|
|
Approvals
|
Overview of devices/part numbers
|
||||
---|---|---|---|---|
type | OFF-delay | Rated voltage | Terminals | numer Std. Pack |
SNE 4004K | - | AC/DC 24 V 50-60 Hz | Terminal block, rising cage termination | R1.188.0520.0 1 |
SNE 4004K-A | - | AC/DC 24 V 50-60 Hz | Pluggable connector, rising cage termination | R1.188.0590.0 1 |
SNE 4004KV | 0,5 s | DC 24 V | Terminal block, rising cage termination | R1.188.0550.0 1 |
1 s | DC 24 V | Terminal block, rising cage termination | R1.188.0560.0 1 | |
2 s | DC 24 V | Terminal block, rising cage termination | R1.188.0570.0 1 | |
3 s | DC 24 V | Terminal block, rising cage termination | R1.188.0580.0 1 | |
SNE 4004KV-A | 0,5 s | DC 24 V | Pluggable connector, rising cage termination | R1.188.0460.0 1 |
1 s | DC 24 V | Pluggable connector, rising cage termination | R1.188.0470.0 1 | |
2 s | DC 24 V | Pluggable connector, rising cage termination | R1.188.0480.0 1 | |
3 s | DC 24 V | Pluggable connector, rising cage termination | R1.188.0490.0 1 |
Send an inquiry
Are you interested in this product? Do you need additional information or individual pricing?
Contact us
Output expansion with relay for base devices in safety applications
• Stop category 0 and 1 according to EN 60204-1 (see “Notes”)
• Applications up to safety category 4 according to EN 954-1
(see “Notes”)
• Single-channel or two-channel control
• SNE 4004K: 4 enabling current paths, undelayed (NO contact)
3 signaling current paths, undelayed (NC contact)
• SNE 4004KV: 4 enabling current paths, OFF-delayed (NO contact)
3 signaling current paths, OFF-delayed (NC contact),
Time buffering
SNE 4004K
SNE 4004KV
SNE 4004K-A and SNE 4004KV-A
A1/A2 supply voltage Y1/Y2 feedback path 13/14,23/24,33/34,43/44, LED K1 ,LED K2 51/52 61/62 tA = response time tR2 = release time |
|
A1/A2 supply voltage Y1/Y2 feedback path 17/18,27/28,37/38,47/48, LED K1 ,LED K2 55/56,65/66 tA = response time tR1 = release time tM = minimum ON time |
The device can only be used as expansion device for safety switching devices.
• The stop and safety categories achieved by the SNE 4004K / KV always depend
on the categories of the base device. The category of the expansion device
cannot exceed that of the base device. By using the SNE 4004KV max.
category 3 according to EN 954-1 can be achieved.
• The expansion relays K1 and K2 are controlled via one or two enabling current
paths, depending on the required level of safety.
• The devices can be combined with all safety switching devices (base devices).
The feedback current path Y1/ Y2 must be wired to the reset or feedback loop of
the base device.
• The device and the contacts must be protected with max. 6 A utilization
category gG or through circuit breakers with trigger characteristic B or C.
• For connecting magnetic switches with reed contacts or sensors
with semiconductor outputs the peak input current must be considered
(see “Technical data”).
• The devices must be installed in a control cabinet with a protection degree
of at least IP 54.
SNE 4004K/KV | SNE 4004K-A/KV-A |
Technical data | SNE 4004K/SNE 4004KV | |
---|---|---|
Function according to EN 60204-1
|
Emergency stop expansion relay
|
|
Function display
|
2 LEDs green
|
|
Function diagram
|
FD 221-13-1 W, FD 221-13-2 W
|
|
Power supply circuit
|
min typ
|
max
|
Rated voltage UN SNE 4004K
|
AC/DC 20,4 V AC/DC 24 V
|
AC/DC 26,4 V
|
Rated voltage UN SNE 4004KV
|
DC 20,4 DC 24 V
|
DC 26,4 V
|
Rated consumption DC
|
1,0 W
|
|
Rated consumption AC
|
1,5 W/2,7 VA
|
|
Residual ripple DC
|
2,4 VSS
|
|
Rated frequency AC
|
50 Hz
|
60Hz
|
Rated current / peak current
|
65 mA/1000 mA
|
80 mA/1800 mA
|
Response time tA
|
20 ms
|
|
Release time tR2 SNE 4004K with emergency stop
|
40 ms
|
|
Minimum ON time tM SNE 4004KV
|
75 ms
|
|
Release time tR1 SNE 4004KV (buffered)
|
0,5 s/1 s/2 s/3 s
|
|
Mean value of the error SNE 4004KV
|
±20 %
|
|
Dispersion SNE 4004KV
|
±2 %
|
|
Feedback current path Y1/Y2
|
1 NC contact, positively driven
|
|
Rated switching voltage Un
|
DC 24 V
|
|
Max. continuous current In
|
0,1 A
|
|
Contact material
|
Ag alloy, gold-plated
|
|
Output circuits
|
||
Enabling current paths
|
4 NO contacts, positively driven
|
|
Rated switching voltage Un
|
AC/DC 230 V
|
|
Max. continuous current In/max. total current
|
6 A/12 A
|
|
Application category according to EN 60947-5-1 3600 h-1
360 h-1 |
AC-15: Ue 230 V, Ie 6 A / DC-13: Ue 24 V, Ie 3 A
DC-13: Ue 24 V, Ie 6 A |
|
Short-circuit protection, max. fuse insert
|
6 A class gG or circuit breaker with trigger characteristic B or C
|
|
Mechanical life
|
10x106
switching cycles
|
|
Contact material
|
Ag alloy, gold-plated
|
|
Contact material
|
2 NC contacts, positively driven
|
|
Rated operating voltage U
UN |
AC/DC 230 V
|
|
Max. continuous current In
|
2 A
|
|
Contact material
|
Ag alloy, gold-plated
|
|
General data
|
||
Creepage distances and clearances between the circuits
|
według EN 60664-1
|
|
Overvoltage category
|
III
|
|
Rated impulse voltage
|
4 kV
|
|
Rated voltage
|
AC 300 V
|
|
Degree of pollution of the device: inside / outside
|
2/3
|
|
Protection degree according to DIN EN 60529 (housing / terminals)
|
IP 40/IP 20
|
|
Ambient temperature / storage temperature
|
-25 - +55 °C/-25 - +75 °C
|
|
Dimension diagram
|
K 4-1 (screw terminals)/ K 4-2 (pluggable terminals)
|
|
Rated cross sections fine-stranded/solid
or fine-stranded with ferrules
|
2x0,14 - 0,75 mm2/1x0,14 - 2,5 mm2
1x0,25 - 2,5 mm2/2x0,25 - 0,5 mm2
|
|
Permissible tightening torque
|
0,5 – 0,6 Nm
|
|
Weight |
0,20 kg
|
|
Accessories
|
-
|
|
Approvals
|
Overview of devices/part numbers
|
||||
---|---|---|---|---|
type | OFF-delay | Rated voltage | Terminals | numer Std. Pack |
SNE 4004K | - | AC/DC 24 V 50-60 Hz | Terminal block, rising cage termination | R1.188.0520.0 1 |
SNE 4004K-A | - | AC/DC 24 V 50-60 Hz | Pluggable connector, rising cage termination | R1.188.0590.0 1 |
SNE 4004KV | 0,5 s | DC 24 V | Terminal block, rising cage termination | R1.188.0550.0 1 |
1 s | DC 24 V | Terminal block, rising cage termination | R1.188.0560.0 1 | |
2 s | DC 24 V | Terminal block, rising cage termination | R1.188.0570.0 1 | |
3 s | DC 24 V | Terminal block, rising cage termination | R1.188.0580.0 1 | |
SNE 4004KV-A | 0,5 s | DC 24 V | Pluggable connector, rising cage termination | R1.188.0460.0 1 |
1 s | DC 24 V | Pluggable connector, rising cage termination | R1.188.0470.0 1 | |
2 s | DC 24 V | Pluggable connector, rising cage termination | R1.188.0480.0 1 | |
3 s | DC 24 V | Pluggable connector, rising cage termination | R1.188.0490.0 1 |