The SB08 bushing type current transformers can be used for variety of measuring, revenue metering and protection tasks. The current transformer SB08 is suitable to put around high-voltage bushings in encapsulated switchgear or in power transformers. The SB08 is meant to be mounted under transformer oil (up to 105°C) or in air, nitrogen or SF6-gas. Current transformer may be equipped with a „flux compensation Winding”. This additional feature prevents the measurement being influenced by external magnetic field causes by –for example- high currents in adjacent phases. The transformer can be ordered independently or as a part of a subassembly. Please check Subassembly brochure for more information.
Rated data:
Application | Transformer oil (up to 105°C), air, nitrogen SF6 |
---|---|
Standard | IEC61869-2, IEEE C57.13, CAN/CSA-C60044-1-07, AS60044.1 and others on request |
Rated primary current (I1) | 30….30000A |
Rated secondary current (I2) | 1,5A and others on request |
Rated burden | As required e. g. 2.5, 5, 10, 15, 30VA |
Accuracy class | As required e. g. 0,2S, 5P20, PX, TPY, C800 |
Rated short-time thermal current | 100 x I1, max. 125kA |
Rated insulation level | 0,72/3/-kV |
Rated frequency | As required e. g. 50-60Hz, 16,7Hz |
Secondary leads | 4 or 6mm², l = 1,5m color coded |
Minimal inner diameter | ≥ 50mm |
Limitations for outer diameter | ≤ 1800mm |
Maximum height | ≤ 750mm |
Maximum weight | ≤ 600kg |
Dimensions
Wiring diagram
Are you interested in this product? Do you need additional information or individual pricing?
The SB08 bushing type current transformers can be used for variety of measuring, revenue metering and protection tasks. The current transformer SB08 is suitable to put around high-voltage bushings in encapsulated switchgear or in power transformers. The SB08 is meant to be mounted under transformer oil (up to 105°C) or in air, nitrogen or SF6-gas. Current transformer may be equipped with a „flux compensation Winding”. This additional feature prevents the measurement being influenced by external magnetic field causes by –for example- high currents in adjacent phases. The transformer can be ordered independently or as a part of a subassembly. Please check Subassembly brochure for more information.
Rated data:
Application | Transformer oil (up to 105°C), air, nitrogen SF6 |
---|---|
Standard | IEC61869-2, IEEE C57.13, CAN/CSA-C60044-1-07, AS60044.1 and others on request |
Rated primary current (I1) | 30….30000A |
Rated secondary current (I2) | 1,5A and others on request |
Rated burden | As required e. g. 2.5, 5, 10, 15, 30VA |
Accuracy class | As required e. g. 0,2S, 5P20, PX, TPY, C800 |
Rated short-time thermal current | 100 x I1, max. 125kA |
Rated insulation level | 0,72/3/-kV |
Rated frequency | As required e. g. 50-60Hz, 16,7Hz |
Secondary leads | 4 or 6mm², l = 1,5m color coded |
Minimal inner diameter | ≥ 50mm |
Limitations for outer diameter | ≤ 1800mm |
Maximum height | ≤ 750mm |
Maximum weight | ≤ 600kg |