Solarplast H1Z2Z2-K solar cables
  • Solarplast H1Z2Z2-K solar cables

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: OMERIN

Solarplast H1Z2Z2-K solar cables

The SOLARPLAST® range has been engineered for PV panel-to-panel and array-to-hardware cabling. Ideal for connecting solar modules to charge controller and charge controller to battery pack, these flexible cables are popular with manufacturers and installers. Our single-conductor or twin-conductor SOLARPLAST® cables offer cabling solutions that seamlessly adapt to the PV panel environment and the connector technology solution needed. The cable dimensions have been engineered to fit all the market-leading connectors. The build materials employed led the SOLARPLAST® ange extremely high UV resistance.These extreme-performance cables comfortably handle any weather conditions thrown at them (rain, wind, snow, frost, hail, and more...).



Primary features

  • Double-insulation
  • Excellent UV resistance
  • Very good abrasion resistance
  • Good resistance to environmental stressors (UV, ozone, hydrolysis)
  • LSZH
  • Certified by the Lloyd’s Register to standard EN 50618
  • 1,0/1,0 KV A.C. / 1,5/1,5 KV D.C.
  • Class II
  • From -40°C to +90°C and peaks +120°C
  • Recyclable, RoHS-compliant
  • Duty service life 25 years according to IEC 60216
  • Zero-halogen-LSZH
  • Servive Entrance Cable per UL 854 sections 23 and 24
  • Permanent immersion AD8 per NF C 15-100



Product brief


Construction
Core

Inner insulation
Outer insulation


Packaging

Markings



Standards

Class-5 flexible tinned copper
to IEC 60228
Cross-linked LSZH compound

Cross-linked LSZH compound



Reels, drums, coils

OMERIN SOLARPLAST H1Z2Z2-K
1x cross section mm2 - Year/Month - 1.0/1.0 kV A.C

EN 50618
Smoke density test-classed to standard IEC 61034-2 as (low smoke)
Gases evolved and corrosive fume generation test-classed to standards IEC 60754-1 and IEC 60754-2 as (zero-halogen)
UV and ozone resistances to EN 50618
Schock resistance according to standard (Impact-Resistance Test)
Crush resistance according to standard UL 854.24 (Crushing-Resistance Tests)
Thermal and mechanical performance specs
Ambient temperature range
Max. conductor temperature
Short-circuit temperature rating
Thermal endurance

Bending radius
-40°C to +90°C
+120°C

+250°C
20.000 h aging at 120°C
to IEC 60216
to 6 x cable diameter (mm)

Electrical performance specs

Conductor resistance at 20°C
Rated voltage

Peak voltage
Test voltage
Maximum current
rating

see table
1.0/1.0 kV A.C – 1.5/1.5 kV D.C.
1.2 kV A.C. – 1.8 kV D.C.
6.5 kV A.C. – 15 kV D.C.

to EN 50618



Cross-section
[N x mm2]
Approx. overall diameter
[mm]
Conductor resistance
[Ω/km]
Approx. cable mass
[kg/km]
1 x 2.5 5.2 5.8 8.21 38
1 x 4 5.3 5.9 5.09 55
1 x 6 5.7 6.3 3.39 76
1 x 10 7.1 7.7 1.95 113
1 x 16 8.4 9.2 1.24 174
1 x 25 10.9 12.1 0.795 270


Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

The SOLARPLAST® range has been engineered for PV panel-to-panel and array-to-hardware cabling. Ideal for connecting solar modules to charge controller and charge controller to battery pack, these flexible cables are popular with manufacturers and installers. Our single-conductor or twin-conductor SOLARPLAST® cables offer cabling solutions that seamlessly adapt to the PV panel environment and the connector technology solution needed. The cable dimensions have been engineered to fit all the market-leading connectors. The build materials employed led the SOLARPLAST® ange extremely high UV resistance.These extreme-performance cables comfortably handle any weather conditions thrown at them (rain, wind, snow, frost, hail, and more...).



Primary features

  • Double-insulation
  • Excellent UV resistance
  • Very good abrasion resistance
  • Good resistance to environmental stressors (UV, ozone, hydrolysis)
  • LSZH
  • Certified by the Lloyd’s Register to standard EN 50618
  • 1,0/1,0 KV A.C. / 1,5/1,5 KV D.C.
  • Class II
  • From -40°C to +90°C and peaks +120°C
  • Recyclable, RoHS-compliant
  • Duty service life 25 years according to IEC 60216
  • Zero-halogen-LSZH
  • Servive Entrance Cable per UL 854 sections 23 and 24
  • Permanent immersion AD8 per NF C 15-100



Product brief


Construction
Core

Inner insulation
Outer insulation


Packaging

Markings



Standards

Class-5 flexible tinned copper
to IEC 60228
Cross-linked LSZH compound

Cross-linked LSZH compound



Reels, drums, coils

OMERIN SOLARPLAST H1Z2Z2-K
1x cross section mm2 - Year/Month - 1.0/1.0 kV A.C

EN 50618
Smoke density test-classed to standard IEC 61034-2 as (low smoke)
Gases evolved and corrosive fume generation test-classed to standards IEC 60754-1 and IEC 60754-2 as (zero-halogen)
UV and ozone resistances to EN 50618
Schock resistance according to standard (Impact-Resistance Test)
Crush resistance according to standard UL 854.24 (Crushing-Resistance Tests)
Thermal and mechanical performance specs
Ambient temperature range
Max. conductor temperature
Short-circuit temperature rating
Thermal endurance

Bending radius
-40°C to +90°C
+120°C

+250°C
20.000 h aging at 120°C
to IEC 60216
to 6 x cable diameter (mm)

Electrical performance specs

Conductor resistance at 20°C
Rated voltage

Peak voltage
Test voltage
Maximum current
rating

see table
1.0/1.0 kV A.C – 1.5/1.5 kV D.C.
1.2 kV A.C. – 1.8 kV D.C.
6.5 kV A.C. – 15 kV D.C.

to EN 50618



Cross-section
[N x mm2]
Approx. overall diameter
[mm]
Conductor resistance
[Ω/km]
Approx. cable mass
[kg/km]
1 x 2.5 5.2 5.8 8.21 38
1 x 4 5.3 5.9 5.09 55
1 x 6 5.7 6.3 3.39 76
1 x 10 7.1 7.7 1.95 113
1 x 16 8.4 9.2 1.24 174
1 x 25 10.9 12.1 0.795 270


Comments (0)