Straight resistant mini sensor ACT-26

Mini straight resistant sensor used for precise liquid and gas mediums temperature measurement. Temperature range -50°C - +250°C. Protection shields made from steel 1.4571 allows for aggressive media measurement. Sensor is placed in additional shield and assembled with screw.
 
SPECIFICATION:
Type Execution
ACT-21 Normal
ACT-21/EXI Spark safe
SENSOR TECHNICAL PARAMETERS
Version Characteristic Measurement resistor Measurement range Accuracy class Max measurement current Connection type
normal
shockproof
according to PN-EN-60751 1xPt100, 2xPt100 from -50°C
up to +250°C
B 8 mA 2 cables
1xPt100 A 5 mA 3, 4
cables
-50°C+150°C 1/3 B DIN 2 mA

Shield
diameter
d[mm]

material according to
WNr/ DIN

material according to
ASTM /AISI

length
L[mm]

Ø3, Ø4, Ø5 , Ø6 1.4571 316 Ti arbitrary

Additional shield
diameter
d[mm]

material according to
WNr/ DIN

material according to
ASTM /AISI

length
L[mm]

Stub pipe thread

Ø3, Ø4, Ø5 , Ø6 1.4571 316 Ti arbitrary M20x1,5 G1/2” G3/4” G3/8”

Connection head
Type Max operation temperature Material
MA +100O AL
Max operation pressure
1,6MPa



Marking:
A. Execution
A
 
normal
-
  Spark safe /Exi
B. Resistor type
B
  Single 1xPt100
  Double 2xPt100
C. Accuracy class
C
 
B
B
 
A
A
 
1/3 B DIN
1/3 B DIN
D. Connection type
 
 
2 - cables
2p
 
3 - cables
3p
 
4 - cables
4p
E. Sensor shield diameter d
E
 
Ø6
6
F. Shield immersion length L1
E
 
L1
give in mm
G. Additional shield diameter d
F
 
Ø6
8
H. Additional shield material
G
 
1.4571
1.4571
I. Stub pipe thread D
H
 
M20x1,5
M20x1,5
 
G1/2"
G1/2
 
G3/4"
G3/4
 
G3/8"
G3/8"
J. Additional shield length L
I
 
LK
give in mm
K.Sensor type
K
 
normal
Z
 
shockproof
W
 

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Mini straight resistant sensor used for precise liquid and gas mediums temperature measurement. Temperature range -50°C - +250°C. Protection shields made from steel 1.4571 allows for aggressive media measurement. Sensor is placed in additional shield and assembled with screw.
 
SPECIFICATION:
Type Execution
ACT-21 Normal
ACT-21/EXI Spark safe
SENSOR TECHNICAL PARAMETERS
Version Characteristic Measurement resistor Measurement range Accuracy class Max measurement current Connection type
normal
shockproof
according to PN-EN-60751 1xPt100, 2xPt100 from -50°C
up to +250°C
B 8 mA 2 cables
1xPt100 A 5 mA 3, 4
cables
-50°C+150°C 1/3 B DIN 2 mA

Shield
diameter
d[mm]

material according to
WNr/ DIN

material according to
ASTM /AISI

length
L[mm]

Ø3, Ø4, Ø5 , Ø6 1.4571 316 Ti arbitrary

Additional shield
diameter
d[mm]

material according to
WNr/ DIN

material according to
ASTM /AISI

length
L[mm]

Stub pipe thread

Ø3, Ø4, Ø5 , Ø6 1.4571 316 Ti arbitrary M20x1,5 G1/2” G3/4” G3/8”

Connection head
Type Max operation temperature Material
MA +100O AL
Max operation pressure
1,6MPa



Marking:
A. Execution
A
 
normal
-
  Spark safe /Exi
B. Resistor type
B
  Single 1xPt100
  Double 2xPt100
C. Accuracy class
C
 
B
B
 
A
A
 
1/3 B DIN
1/3 B DIN
D. Connection type
 
 
2 - cables
2p
 
3 - cables
3p
 
4 - cables
4p
E. Sensor shield diameter d
E
 
Ø6
6
F. Shield immersion length L1
E
 
L1
give in mm
G. Additional shield diameter d
F
 
Ø6
8
H. Additional shield material
G
 
1.4571
1.4571
I. Stub pipe thread D
H
 
M20x1,5
M20x1,5
 
G1/2"
G1/2
 
G3/4"
G3/4
 
G3/8"
G3/8"
J. Additional shield length L
I
 
LK
give in mm
K.Sensor type
K
 
normal
Z
 
shockproof
W
 