Manufacturer: FRER

TDB ... - Current transformers for cooperation with current relays Type B type

TDB... - Sensors for earth leakage relays Type B


TDB series sensors are able to measure AC and DC currents with a DC-10kHz bandwidth, and 1mA reso-lution.  TDB sensors have an integrated degauss function with DC offset zeroing, which is automatically activated at Power On, or by relay command. This function sets to zero the Dc current measuring errors (DC  offset)  caused  by  terrestral  magnetic  field,  permanent  magnets,  DC  coil  ets...,  temperature  drifts,  mechanical shocks or vibrations. The measuring error of the RMS current (AC+DC) is proportional to the line current and it depends on the geometrical layout of the conductors passing through the sensor hole. It also depend on the distance and the geometrical layout of  the nearby conductors passing outside the sensor hole. The IΔn setting <100mA will be possible only by centering the conductors and with controlled environment conditions (temperature, vibration, EMI).

Technical Data
 
self estinguishing thermoplastic material UL 94-V0
max. nominal line current 400Arms
Single-phase or 3phase with or without neutral
residual current measure IΔ Type B – True RMS
measure full range TDB…3CM: IΔ 1mA÷1,5Aac±2,1Adc
TDB…003: IΔ 10mA÷15Aac±21Adc
sensor degauss 500ms voltage pulse
DC offset after degauss < ±1mAdc
DC offset over temperature < ±100µAdc/oC
(< ±6mAdc@85oC) [-15 oC…+25 oC…+85 oC]
line current error with centred cables <30μA/A (<3mArms@100A)
sensor connections 4 wires [+Vcc, GND, Vref, Vin]
sensor cable 4 wires 1mm2
bandwidth DC – 10kHz (-3dB)
shield high EMI environments
maximum length 10m with shield
safety IEC 6189-1
maximum primary voltage insulation 720Vac
reference voltage 0,72 kV
test voltage 3kV, 50Hz, 1min.
protection degree IP20
operating temperature 0...+50°C, U.R./R.H. <90% n.c.
level of insulation according to IEC 61010-1, IEC 60947-1
storage temperature -20...+70°C
manufactured according to IEC/EN 61869-1
 
Ordering codes
 
Sensor type TDB _ _ _ _ _ _
Size Ø 28 mm 0 2 8  
Ø 60 mm 0 6 0  
Ø 90 mm 0 9 0  
Current 30-300mA 3 CM
300mA-3A 0 0 3

Dimensions

TDB028 TDB060
TDB090  
 

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

TDB... - Sensors for earth leakage relays Type B


TDB series sensors are able to measure AC and DC currents with a DC-10kHz bandwidth, and 1mA reso-lution.  TDB sensors have an integrated degauss function with DC offset zeroing, which is automatically activated at Power On, or by relay command. This function sets to zero the Dc current measuring errors (DC  offset)  caused  by  terrestral  magnetic  field,  permanent  magnets,  DC  coil  ets...,  temperature  drifts,  mechanical shocks or vibrations. The measuring error of the RMS current (AC+DC) is proportional to the line current and it depends on the geometrical layout of the conductors passing through the sensor hole. It also depend on the distance and the geometrical layout of  the nearby conductors passing outside the sensor hole. The IΔn setting <100mA will be possible only by centering the conductors and with controlled environment conditions (temperature, vibration, EMI).

Technical Data
 
self estinguishing thermoplastic material UL 94-V0
max. nominal line current 400Arms
Single-phase or 3phase with or without neutral
residual current measure IΔ Type B – True RMS
measure full range TDB…3CM: IΔ 1mA÷1,5Aac±2,1Adc
TDB…003: IΔ 10mA÷15Aac±21Adc
sensor degauss 500ms voltage pulse
DC offset after degauss < ±1mAdc
DC offset over temperature < ±100µAdc/oC
(< ±6mAdc@85oC) [-15 oC…+25 oC…+85 oC]
line current error with centred cables <30μA/A (<3mArms@100A)
sensor connections 4 wires [+Vcc, GND, Vref, Vin]
sensor cable 4 wires 1mm2
bandwidth DC – 10kHz (-3dB)
shield high EMI environments
maximum length 10m with shield
safety IEC 6189-1
maximum primary voltage insulation 720Vac
reference voltage 0,72 kV
test voltage 3kV, 50Hz, 1min.
protection degree IP20
operating temperature 0...+50°C, U.R./R.H. <90% n.c.
level of insulation according to IEC 61010-1, IEC 60947-1
storage temperature -20...+70°C
manufactured according to IEC/EN 61869-1
 
Ordering codes
 
Sensor type TDB _ _ _ _ _ _
Size Ø 28 mm 0 2 8  
Ø 60 mm 0 6 0  
Ø 90 mm 0 9 0  
Current 30-300mA 3 CM
300mA-3A 0 0 3

Dimensions

TDB028 TDB060
TDB090  
 