Control Voltage | 2.4A | 4.2A |
---|---|---|
4-6 VDC | DRA3P48D2 | DRA3P48D4 |
18-28 VDC | DRA3P48E2 | DRA3P48E4 |
36-60 VDC | DRA3P48C2 | DRA3P48C4 |
90-140 VDC | DRA3P48B2 | DRA3P48B4 |
200-265 VDC | DRA3P48A2 | DRA3P48A4 |
Description | 2.4A | 4.2A |
---|---|---|
Maximum Load Current [Arms] | 0.15 | 0.15 |
Maximum Leakage Current at Rated Voltage [mArms] | 1.0 | 1.0 |
Maximum dV/dt at Off-state at Maximum Rated Voltage [V/usec] | 500 | 500 |
Minimum dV/dt at Off-state at Maximum Rated Voltage [V/usec] | 1.15 per channel | 1.15 per channel |
Maximum Single Pulse Current (50/60Hz) [Apk] | 410/375 | 410/375 |
IEC 60947 Rated at 240 V, 40 degrees Celsius [kW] | 0.37 | 0.37 |
IEC 60947 Rated at 380 V, 40 degrees Celsius [kW] | 0.75 | 0.75 |
IEC 60947 Rated at 400 V, 40 degrees Celsius [kW] | 0.75 | 0.75 |
Minimum Power Factor (at maximum load) | 0.5 | 0.5 |
Min/Max Twisted/Solid Load Wire [IEC mm2] | 0.5-4.0 | 0.5-4.0 |
Load Clamp Screw Torque Range [Nm] | 1.36 | 1.36 |
Description | DRA3P48Dx | DRA3P48Ex | DRA3P48Cx | DRA3P48Bx | DRA3P48Ax |
---|---|---|---|---|---|
Control Voltage Range | 4 - 6 VDC | 18 - 28 VDC | 36 - 60 VAC | 90 - 140 VAC | 200 - 265 VAC |
Rated Control Voltage | 5 VDC | 24 VDC | 48 VAC | 120 VAC | 230 VAC |
Minimum Turn-On Voltage | 4 VDC | 18 VDC | 36 VAC | 90 VAC | 200 VAC |
Minimum Turn-Off Voltage | 2 VDC | 4 VDC | 10 VAC | 20 VAC | 60 VAC |
Minimum Input Current [mA] | 17 | 15 | 7.5 | 5 | 4.5 |
Maximum Input Current [mA] | 35 | 25 | 13.5 | 8 | 5.7 |
Rated Input Impedance [Ohms] | 120 | 1.2K | 4.2K | 16K | 46K |
Maximum Turn-On Time [msec] | ½ cycle | ½ cycle | 20ms | 20ms | 20ms |
Maximum Turn-Off Time [msec] | ½ cycle | ½ cycle | 30ms | 30ms | 30ms |
Min/Max Twisted/Solid Input Wire [IEC mm2] | 0.5-2.5 | 0.5-2.5 | 0.5-2.5 | 0.5-2.5 | 0.5-2.5 |
Control Terminal Screw Torque Range [Nm] | 0.485 | 0.485 | 0.485 | 0.485 | 0.485 |
Description | Parameters |
---|---|
Dielectric Strength, Input to Output (50/60Hz) | 3750 Vrms |
Minimum Insulation Resistance (at 500V DC) | 109 Ohms |
Maximum Capacitance, Input/Output | 20pF |
Ambient Temperature Range (Operating) | -20 to 60 degrees Celsius |
Ambient Temperature Range (Storage) | -40 to 85 degrees Celsius |
LED Status Indicator for Control Input | On: Green |
Weight (Typical) | 135 g |
Housing Material (Bottom Cover) | PVC Class V0 (UL94) |
Housing Material (End Elements) | Poliamid Class V0 (UL94) |
Are you interested in this product? Do you need additional information or individual pricing?
Control Voltage | 2.4A | 4.2A |
---|---|---|
4-6 VDC | DRA3P48D2 | DRA3P48D4 |
18-28 VDC | DRA3P48E2 | DRA3P48E4 |
36-60 VDC | DRA3P48C2 | DRA3P48C4 |
90-140 VDC | DRA3P48B2 | DRA3P48B4 |
200-265 VDC | DRA3P48A2 | DRA3P48A4 |
Description | 2.4A | 4.2A |
---|---|---|
Maximum Load Current [Arms] | 0.15 | 0.15 |
Maximum Leakage Current at Rated Voltage [mArms] | 1.0 | 1.0 |
Maximum dV/dt at Off-state at Maximum Rated Voltage [V/usec] | 500 | 500 |
Minimum dV/dt at Off-state at Maximum Rated Voltage [V/usec] | 1.15 per channel | 1.15 per channel |
Maximum Single Pulse Current (50/60Hz) [Apk] | 410/375 | 410/375 |
IEC 60947 Rated at 240 V, 40 degrees Celsius [kW] | 0.37 | 0.37 |
IEC 60947 Rated at 380 V, 40 degrees Celsius [kW] | 0.75 | 0.75 |
IEC 60947 Rated at 400 V, 40 degrees Celsius [kW] | 0.75 | 0.75 |
Minimum Power Factor (at maximum load) | 0.5 | 0.5 |
Min/Max Twisted/Solid Load Wire [IEC mm2] | 0.5-4.0 | 0.5-4.0 |
Load Clamp Screw Torque Range [Nm] | 1.36 | 1.36 |
Description | DRA3P48Dx | DRA3P48Ex | DRA3P48Cx | DRA3P48Bx | DRA3P48Ax |
---|---|---|---|---|---|
Control Voltage Range | 4 - 6 VDC | 18 - 28 VDC | 36 - 60 VAC | 90 - 140 VAC | 200 - 265 VAC |
Rated Control Voltage | 5 VDC | 24 VDC | 48 VAC | 120 VAC | 230 VAC |
Minimum Turn-On Voltage | 4 VDC | 18 VDC | 36 VAC | 90 VAC | 200 VAC |
Minimum Turn-Off Voltage | 2 VDC | 4 VDC | 10 VAC | 20 VAC | 60 VAC |
Minimum Input Current [mA] | 17 | 15 | 7.5 | 5 | 4.5 |
Maximum Input Current [mA] | 35 | 25 | 13.5 | 8 | 5.7 |
Rated Input Impedance [Ohms] | 120 | 1.2K | 4.2K | 16K | 46K |
Maximum Turn-On Time [msec] | ½ cycle | ½ cycle | 20ms | 20ms | 20ms |
Maximum Turn-Off Time [msec] | ½ cycle | ½ cycle | 30ms | 30ms | 30ms |
Min/Max Twisted/Solid Input Wire [IEC mm2] | 0.5-2.5 | 0.5-2.5 | 0.5-2.5 | 0.5-2.5 | 0.5-2.5 |
Control Terminal Screw Torque Range [Nm] | 0.485 | 0.485 | 0.485 | 0.485 | 0.485 |
Description | Parameters |
---|---|
Dielectric Strength, Input to Output (50/60Hz) | 3750 Vrms |
Minimum Insulation Resistance (at 500V DC) | 109 Ohms |
Maximum Capacitance, Input/Output | 20pF |
Ambient Temperature Range (Operating) | -20 to 60 degrees Celsius |
Ambient Temperature Range (Storage) | -40 to 85 degrees Celsius |
LED Status Indicator for Control Input | On: Green |
Weight (Typical) | 135 g |
Housing Material (Bottom Cover) | PVC Class V0 (UL94) |
Housing Material (End Elements) | Poliamid Class V0 (UL94) |