Network parameter analyzer integrated with a transformer - MTA36
  • Network parameter analyzer integrated with a transformer - MTA36

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: SACI

Network parameter analyzer integrated with a transformer - MTA36

MTA36 Power meter Integrated in a transformer.
With a revolutionary design MTA36 combines the transformer measurement and the network analyzer in one equipment, with its communication possibilities create a easy to install and versatile device.


MTA36 advantages

  • Cost effective solution
  • Reduces installation time
  • Improve reliability of the network
  • Split core technolgy
  • Lora Communication
  • Compact design
  • Free wireless communications through Radio Frequency (RF)
  • Up to 10,000 meters
  • Easy access to network data from the control center



Compact Design up to 36 mm diameter wire


Quick and safe closure system alows to adjust the device to the wire up to 36mm diameter.



Split core technology - avoid unnecessary network outages during installation


4 available versions: deppending on communication and desired net
  • LORA single-phase
  • LORA three-phase (3P4W)
  • RS485 single-phase
  • RS485 three-phase (3P4W)


Up to 10,000 meters


The distance between the control center and the analyzers installation can reach 10,000 meters, which is a great advantage. The built-in module allows easy access from the control center to network data.




Technical data


INPUT
Rated voltage 3x230/400 V AC
Overload 1,2 Un
Impendance ≥1.7 MΩ/phase
Rated current 50 (600)A
Overload continuous 1.2 In
Overload instantaneous 10 In/5s
Burden ≤0.2 VA /fazę
Cable section Minimum: 16 mm2
Maximum: 510 mm2


AUXILIARY VOLTAGE
Auxiliary voltage AC/DC 80 - 270 V/td>
Burden ≤5VA


OUTPUT
RS485 port Modbus
Transmission rate Programmable up to 9,600 bps
Connection 2 wires
LoRa® Programmable up to 9,600 bps
Max. distance Up to 1,000 m indoor
Up to 1,000 m outdoor


GENERAL FEATURES
Dimensions 88.5 x 71 x 204 mm
Weight 0,489 kg
Protection IP 20
Operating temperature -10 - 55 °C
Storage temperature -25 - 70 °C
Humidity 5 - 95%



Electrical parameters


Parameter Unit L1 L2 L3 Total Medium Max./min.
Voltage (phase – neutral) V, kV  
Voltage (phase – phase) V, kV  
Current A, kA  
Neutral current A, kA      
Active power (P) kW, MW, GW
Reactive power (Q) kvar, Mvar, Gvar
Apparent power (S) kVA
Power factor (cos φ) PF
Frequency Hz        
Import active energy (EP+) Wh, M Wh, G Wh          
Export active energy (EP-) Wh, M Wh, G Wh          
Import reactive energy (Eq+) kvarh, M varh, G varh          
Export reactive energy (Eq-) kvarh, M varh, G varh          
Puncture Temperature °C          
THD Current and Voltage A, V      
Harmonic RMS-U and I (2-31) %      
Unbalanced -U and I %          



Accuracy


Parameter Operation range Accuracy
Voltage 2,5-120 % 0,5%
Current 0,1-120 % 0,5%
Active power 1-120 % 1%
Reactive power 1-120 % 1%
Apparent powera 1-120 % 1%
Power factor ± 0,5 % 1%
Frequency 45-65 Hz ± 0,01 Hz
Active energy 1-120 % Class 1
Reactive energy 1-120 % Class 2



Communication module


INPUT
T/R frequency 860 MHz〜900 MHz, 0,1 MHz
Transmitting power +17.6 dBm/100 mW
Receiving sensitivity 139 dBm@0,81 Kbps
Auxiliary voltage AC/DC 80〜270V
Consumption <2VA



Wymiary





Połączenia


Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

MTA36 Power meter Integrated in a transformer.
With a revolutionary design MTA36 combines the transformer measurement and the network analyzer in one equipment, with its communication possibilities create a easy to install and versatile device.


MTA36 advantages

  • Cost effective solution
  • Reduces installation time
  • Improve reliability of the network
  • Split core technolgy
  • Lora Communication
  • Compact design
  • Free wireless communications through Radio Frequency (RF)
  • Up to 10,000 meters
  • Easy access to network data from the control center



Compact Design up to 36 mm diameter wire


Quick and safe closure system alows to adjust the device to the wire up to 36mm diameter.



Split core technology - avoid unnecessary network outages during installation


4 available versions: deppending on communication and desired net
  • LORA single-phase
  • LORA three-phase (3P4W)
  • RS485 single-phase
  • RS485 three-phase (3P4W)


Up to 10,000 meters


The distance between the control center and the analyzers installation can reach 10,000 meters, which is a great advantage. The built-in module allows easy access from the control center to network data.




Technical data


INPUT
Rated voltage 3x230/400 V AC
Overload 1,2 Un
Impendance ≥1.7 MΩ/phase
Rated current 50 (600)A
Overload continuous 1.2 In
Overload instantaneous 10 In/5s
Burden ≤0.2 VA /fazę
Cable section Minimum: 16 mm2
Maximum: 510 mm2


AUXILIARY VOLTAGE
Auxiliary voltage AC/DC 80 - 270 V/td>
Burden ≤5VA


OUTPUT
RS485 port Modbus
Transmission rate Programmable up to 9,600 bps
Connection 2 wires
LoRa® Programmable up to 9,600 bps
Max. distance Up to 1,000 m indoor
Up to 1,000 m outdoor


GENERAL FEATURES
Dimensions 88.5 x 71 x 204 mm
Weight 0,489 kg
Protection IP 20
Operating temperature -10 - 55 °C
Storage temperature -25 - 70 °C
Humidity 5 - 95%



Electrical parameters


Parameter Unit L1 L2 L3 Total Medium Max./min.
Voltage (phase – neutral) V, kV  
Voltage (phase – phase) V, kV  
Current A, kA  
Neutral current A, kA      
Active power (P) kW, MW, GW
Reactive power (Q) kvar, Mvar, Gvar
Apparent power (S) kVA
Power factor (cos φ) PF
Frequency Hz        
Import active energy (EP+) Wh, M Wh, G Wh          
Export active energy (EP-) Wh, M Wh, G Wh          
Import reactive energy (Eq+) kvarh, M varh, G varh          
Export reactive energy (Eq-) kvarh, M varh, G varh          
Puncture Temperature °C          
THD Current and Voltage A, V      
Harmonic RMS-U and I (2-31) %      
Unbalanced -U and I %          



Accuracy


Parameter Operation range Accuracy
Voltage 2,5-120 % 0,5%
Current 0,1-120 % 0,5%
Active power 1-120 % 1%
Reactive power 1-120 % 1%
Apparent powera 1-120 % 1%
Power factor ± 0,5 % 1%
Frequency 45-65 Hz ± 0,01 Hz
Active energy 1-120 % Class 1
Reactive energy 1-120 % Class 2



Communication module


INPUT
T/R frequency 860 MHz〜900 MHz, 0,1 MHz
Transmitting power +17.6 dBm/100 mW
Receiving sensitivity 139 dBm@0,81 Kbps
Auxiliary voltage AC/DC 80〜270V
Consumption <2VA



Wymiary





Połączenia