VARPREN® 155 UL Class F lead wires UL and cUL approval
  • VARPREN® 155 UL Class F lead wires UL and cUL approval

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: OMERIN

VARPREN® 155 UL Class F lead wires UL and cUL approval

Characteristics

• Continuous operating temperatures: -10 °C to +150 °C
• Good resistance to common chemical influences and impregnating varnishes.
• Rated voltage: as per style no.
• Test voltage: 10 x Rated voltage.

Standard products

• Standard insulation colours: white, black, blue, brown, red or yellow/green. 

Approvals - standards

• UL approval as per standard UL 758 - File no.: E101965.
• cUL approval (CSA) as per standard C22.2 No. 210 - File no.: E101965.
• “Horizontal flame test” as per UL approval.
• “FT2 flame rating” as per cUL approval.

Applications

• Class F cabling for electric motors.
• Lights
• Industrial cabling in hot atmospheres up to +150 °C.

Options

• Nickel-plated copper core: contact us.
• Other colours: contact us.
• Other nominal cross-sections: contact us.
• Other options: contact us.

1 • Flexible bare copper or tin-plated core
2 • Insulation: Varpren®.

 

 
Nominal cross-section  
AWG [mm2] Nominal stranding Avg thickness of insulation (mm) Nominal diameter* (mm)
22 0.34 19 x 0.15 0,76 2.35
- 0.5 19 x 0.18 0,76 2.5
20 0,60 19 x 0,20 0,76 2,6
- 0.75 24 x 0.20 0,76 2.7
18 0.93 19 x 0.25 0,76 2.8
- 1 32 x 0.20 0,76 2.9
16 1.34 19 x 0.30 0,76 3.1
- 1.5 30 x 0.25 0,76 3.15
14 - 19 x 0.37 0.76 3.4
- 2.5 50 x 0.25 0.76 3.6
12 - 37 x 0.34 0.76 4.0
- 4 52 x 0.30 0.76 4.1
10 - 37 x 0.43 0.76 4.7
- 6 84 x 0.30 0.76 4.8
8 - 70 x 0.40 1.14 6.3
- 10 77 x 0.40 1.14 7.0
6 - 105 x 0.40 1.52 8.4
- 16 119 x 0.40 1.52 8.8
4 - 168 x 0.40 1.52 9.8
- 25 196 x 0.40 1.52 10.4
2 35 259 x 0.40 2.04 11.7
1 - 342 x 0.40 2.04 13.6
- 50 370 x 0.40 2.04 14.3
1/0 - 425 x 0.40 2.04 15.0
2/0 70 340 x 0.50 2.04 16.5
3/0 - 434 x 0.50 2.04 17.7
- 95 475 x 0.50 2.04 18.7
4/0 - 546 x 0.50 2.04 19.6
  conducting metal BCDEFG

KEY

Conducting metal
B Tin-plated copper
B* Tin-plated copper (Ø > 0.38 mm)
C Nickel-plated copper
D Silver-plated copper
E Nickel
F Bare copper
F* Bare copper (Ø > 0.38 mm)
G Nickel-plated copper 27 %



AWM I A     Internal wiring, not subject to mechanical abuse
AWM I A/B   Internal wiring
AWM II A/B   External or Internal wiring
NS   Not Specified
VNS   Voltage Not Specified

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Characteristics

• Continuous operating temperatures: -10 °C to +150 °C
• Good resistance to common chemical influences and impregnating varnishes.
• Rated voltage: as per style no.
• Test voltage: 10 x Rated voltage.

Standard products

• Standard insulation colours: white, black, blue, brown, red or yellow/green. 

Approvals - standards

• UL approval as per standard UL 758 - File no.: E101965.
• cUL approval (CSA) as per standard C22.2 No. 210 - File no.: E101965.
• “Horizontal flame test” as per UL approval.
• “FT2 flame rating” as per cUL approval.

Applications

• Class F cabling for electric motors.
• Lights
• Industrial cabling in hot atmospheres up to +150 °C.

Options

• Nickel-plated copper core: contact us.
• Other colours: contact us.
• Other nominal cross-sections: contact us.
• Other options: contact us.

1 • Flexible bare copper or tin-plated core
2 • Insulation: Varpren®.

 

 
Nominal cross-section  
AWG [mm2] Nominal stranding Avg thickness of insulation (mm) Nominal diameter* (mm)
22 0.34 19 x 0.15 0,76 2.35
- 0.5 19 x 0.18 0,76 2.5
20 0,60 19 x 0,20 0,76 2,6
- 0.75 24 x 0.20 0,76 2.7
18 0.93 19 x 0.25 0,76 2.8
- 1 32 x 0.20 0,76 2.9
16 1.34 19 x 0.30 0,76 3.1
- 1.5 30 x 0.25 0,76 3.15
14 - 19 x 0.37 0.76 3.4
- 2.5 50 x 0.25 0.76 3.6
12 - 37 x 0.34 0.76 4.0
- 4 52 x 0.30 0.76 4.1
10 - 37 x 0.43 0.76 4.7
- 6 84 x 0.30 0.76 4.8
8 - 70 x 0.40 1.14 6.3
- 10 77 x 0.40 1.14 7.0
6 - 105 x 0.40 1.52 8.4
- 16 119 x 0.40 1.52 8.8
4 - 168 x 0.40 1.52 9.8
- 25 196 x 0.40 1.52 10.4
2 35 259 x 0.40 2.04 11.7
1 - 342 x 0.40 2.04 13.6
- 50 370 x 0.40 2.04 14.3
1/0 - 425 x 0.40 2.04 15.0
2/0 70 340 x 0.50 2.04 16.5
3/0 - 434 x 0.50 2.04 17.7
- 95 475 x 0.50 2.04 18.7
4/0 - 546 x 0.50 2.04 19.6
  conducting metal BCDEFG

KEY

Conducting metal
B Tin-plated copper
B* Tin-plated copper (Ø > 0.38 mm)
C Nickel-plated copper
D Silver-plated copper
E Nickel
F Bare copper
F* Bare copper (Ø > 0.38 mm)
G Nickel-plated copper 27 %



AWM I A     Internal wiring, not subject to mechanical abuse
AWM I A/B   Internal wiring
AWM II A/B   External or Internal wiring
NS   Not Specified
VNS   Voltage Not Specified

Comments (0)