Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Photos are for informational purposes only. View product specification
please use latin characters
Characteristics • Continuous operating temperatures: -40 °C to +155 °C• Excellent tearing strength. • Minimum bending radius: 5 x D. • Rated voltage: 600/1000 V • Test voltage: 3500 V Standard products • All colours including two-coloured.Approvals - standards • Halogen-free: EN 60754-1.• Fire retardant: NF C 32-070 test C1. • Flame retardant: EN 60332-1-2 / NF C 32-070 test C2. • Test for vertical flame propagation of vertically-mounted bunched wires or cables – Category A: IEC 60332-3-22. • Low corrosivity of gas emissions: EN 60754-2. • Low smoke density: EN 61034-2. Applications • Class F cabling for electric motors.Options • Bare copper core: contact us. |
![]() 1 • Flexible tin-plated copper core – class 5 as per IEC 60228 |
Flexible core • class 5 as per IEC 60228 |
INSULATED WIRE OR CABLE |
||||
---|---|---|---|---|---|
Nominal cross-section [mm2] | Nominal stranding | Maximum linear resistance at 20 °C (Ω/km) | Nominal thickness of insulation (mm) |
Nominal diameter [mm] |
Approximate linear weight [kg/km] |
0,5 | 16 x 0,20 | 40,1 | 0,6 | 2,2 | 9,0 |
0,75 | 24 x 0,20 | 26,7 | 0,6 | 2,4 | 11,7 |
1 | 32 x 0,20 | 20,0 | 0,6 | 2,5 | 13,8 |
1,5 | 30 x 0,25 | 13,7 | 0,6 | 3,0 | 20,2 |
2,5 | 50 x 0,25 | 8,21 | 0,7 | 3,6 | 31,2 |
4 | 56 x 0,30 | 5,09 | 0,8 | 4,3 | 47,2 |
6 | 84 x 0,30 | 3,39 | 0,8 | 4,9 | 65,9 |
10 | 80 x 0,40 | 1,95 | 1,0 | 6,6 | 120 |
16 | 126 x 0,40 | 1,24 | 1,0 | 7,7 | 172 |
25 | 196 x 0,40 | 0,795 | 1,2 | 9,6 | 270 |
35 | 276 x 0,40 | 0,565 | 1,2 | 10,7 | 355 |
50 | 396 x 0,40 | 0,393 | 1,4 | 12,6 | 502 |
70 | 360 x 0,50 | 0,277 | 1,4 | 14,9 | 693 |
95 | 485 x 0,50 | 0,210 | 1,6 | 17,2 | 913 |
Are you interested in this product? Do you need additional information or individual pricing?
Characteristics • Continuous operating temperatures: -40 °C to +155 °C• Excellent tearing strength. • Minimum bending radius: 5 x D. • Rated voltage: 600/1000 V • Test voltage: 3500 V Standard products • All colours including two-coloured.Approvals - standards • Halogen-free: EN 60754-1.• Fire retardant: NF C 32-070 test C1. • Flame retardant: EN 60332-1-2 / NF C 32-070 test C2. • Test for vertical flame propagation of vertically-mounted bunched wires or cables – Category A: IEC 60332-3-22. • Low corrosivity of gas emissions: EN 60754-2. • Low smoke density: EN 61034-2. Applications • Class F cabling for electric motors.Options • Bare copper core: contact us. |
![]() 1 • Flexible tin-plated copper core – class 5 as per IEC 60228 |
Flexible core • class 5 as per IEC 60228 |
INSULATED WIRE OR CABLE |
||||
---|---|---|---|---|---|
Nominal cross-section [mm2] | Nominal stranding | Maximum linear resistance at 20 °C (Ω/km) | Nominal thickness of insulation (mm) |
Nominal diameter [mm] |
Approximate linear weight [kg/km] |
0,5 | 16 x 0,20 | 40,1 | 0,6 | 2,2 | 9,0 |
0,75 | 24 x 0,20 | 26,7 | 0,6 | 2,4 | 11,7 |
1 | 32 x 0,20 | 20,0 | 0,6 | 2,5 | 13,8 |
1,5 | 30 x 0,25 | 13,7 | 0,6 | 3,0 | 20,2 |
2,5 | 50 x 0,25 | 8,21 | 0,7 | 3,6 | 31,2 |
4 | 56 x 0,30 | 5,09 | 0,8 | 4,3 | 47,2 |
6 | 84 x 0,30 | 3,39 | 0,8 | 4,9 | 65,9 |
10 | 80 x 0,40 | 1,95 | 1,0 | 6,6 | 120 |
16 | 126 x 0,40 | 1,24 | 1,0 | 7,7 | 172 |
25 | 196 x 0,40 | 0,795 | 1,2 | 9,6 | 270 |
35 | 276 x 0,40 | 0,565 | 1,2 | 10,7 | 355 |
50 | 396 x 0,40 | 0,393 | 1,4 | 12,6 | 502 |
70 | 360 x 0,50 | 0,277 | 1,4 | 14,9 | 693 |
95 | 485 x 0,50 | 0,210 | 1,6 | 17,2 | 913 |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent