VARPREN® ST -40 °C to +155 °C
  • VARPREN® ST -40 °C to +155 °C

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: OMERIN

VARPREN® ST -40 °C to +155 °C

Characteristics

• Continuous operating temperatures: -40 °C to +155 °C
• Excellent tearing strength
• Minimum bending radius: 5 x D.
• Rated voltage: 600/1000 V.
• Test voltage: 3500 V.

Standard products

• All colours including two-coloured.

Approvals - standards

• Halogen-free: EN 60754-1.
• Fire retardant: NF C 32-070 test C1.
• Flame retardant: EN 60332-1-2 / NF C 32-070 test C2.
• Test for vertical flame propagation of vertically-mounted bunched wires or cables – Category A: IEC 60332-3-22.
• Low corrosivity of gas emissions: EN 60754-2.
• Low smoke density: EN 61034-2.

Options

• Bare copper core: contact us.
• Nickel-plated copper core: contact us
• Other nominal cross-sections: contact us
• Other nominal stranding: contact us.
• Other options: contact us.


1 • Flexible tin-plated copper core – class 5 as per IEC 60228
2 • Insulation: Varpren®.

 
Flexible core • class 5 as per IEC 60228 INSULATED WIRE OR CABLE
Nominal cross-section [mm2] Nominal stranding Maximum linear resistance at 20 °C (Ω/km) Nominal thickness of insulation (mm) Nominal diameter [mm] Approximate linear weight [kg/km]
0,5 16 x 0,20 40.1 0.6 2.2 9.0
0,75 24 x 0,20 26.7 0.6 2.4 11.7
1 32 x 0,20 20.0 0.6 2.5 13.8
1,5 30 x 0,25 13.7 0,6 3.0 20.2
2,5 50 x 0,25 8.21 0,7 3,6 31.2
4 56 x 0,30 5.09 0,8 4,3 47.2
6 84 x 0,30 3,39 0,8 4,9 65.9
10 80 x 0,40 1,95 1,0 6,6 120
16 126 x 0,40 1,24 1,0 7,7 172
25 196 x 0,40 0,795 1,2 9,6 270
35 276 x 0,40 0,565 1,2 10,7 355
50 396 x 0,40 0,393 1,4 12,6 502
70 360 x 0,50 0,277 1,4 14,9 693
95 485 x 0,50 0,210 1,6 17,2 913

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Characteristics

• Continuous operating temperatures: -40 °C to +155 °C
• Excellent tearing strength
• Minimum bending radius: 5 x D.
• Rated voltage: 600/1000 V.
• Test voltage: 3500 V.

Standard products

• All colours including two-coloured.

Approvals - standards

• Halogen-free: EN 60754-1.
• Fire retardant: NF C 32-070 test C1.
• Flame retardant: EN 60332-1-2 / NF C 32-070 test C2.
• Test for vertical flame propagation of vertically-mounted bunched wires or cables – Category A: IEC 60332-3-22.
• Low corrosivity of gas emissions: EN 60754-2.
• Low smoke density: EN 61034-2.

Options

• Bare copper core: contact us.
• Nickel-plated copper core: contact us
• Other nominal cross-sections: contact us
• Other nominal stranding: contact us.
• Other options: contact us.


1 • Flexible tin-plated copper core – class 5 as per IEC 60228
2 • Insulation: Varpren®.

 
Flexible core • class 5 as per IEC 60228 INSULATED WIRE OR CABLE
Nominal cross-section [mm2] Nominal stranding Maximum linear resistance at 20 °C (Ω/km) Nominal thickness of insulation (mm) Nominal diameter [mm] Approximate linear weight [kg/km]
0,5 16 x 0,20 40.1 0.6 2.2 9.0
0,75 24 x 0,20 26.7 0.6 2.4 11.7
1 32 x 0,20 20.0 0.6 2.5 13.8
1,5 30 x 0,25 13.7 0,6 3.0 20.2
2,5 50 x 0,25 8.21 0,7 3,6 31.2
4 56 x 0,30 5.09 0,8 4,3 47.2
6 84 x 0,30 3,39 0,8 4,9 65.9
10 80 x 0,40 1,95 1,0 6,6 120
16 126 x 0,40 1,24 1,0 7,7 172
25 196 x 0,40 0,795 1,2 9,6 270
35 276 x 0,40 0,565 1,2 10,7 355
50 396 x 0,40 0,393 1,4 12,6 502
70 360 x 0,50 0,277 1,4 14,9 693
95 485 x 0,50 0,210 1,6 17,2 913