Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Photos are for informational purposes only. View product specification
please use latin characters
The voltage sensor range is designed according the IECstandard to meet maximum combability on the market. This product is designed for use in conjunction with devices, which are build according the standard. The voltage sensor cone shape compatible to different manufacturers of T-cable connectors like Cellpack, Nexans, Südkabel, nkt, Tyco Features No calibration on Site is needed |
Dimensions The short form factor enables maximum compatibility to existing installations. The hexagonal nut is |
Installation |
||
The voltage sensor is simple to install; the existing blind plug
|
![]() |
Connection
The voltage sensor is directly connected to a measurement
|
![]() |
|
M8-Subconnector |
![]() |
Specification | |
---|---|
Applied Standards: | IEC61869-1, IEC61869-6, IEC61869-11 |
Primary voltage: | 20000/√3V* |
Voltage factor | 1,9*Un for 8h |
Secondary output: | 3,25/√3V* |
Burden: | 200kOhm±1%, 350pF* |
Insulation level: | 24/50/125kV |
Accuracy classes: | 0,2/0,5/1/3 [&] 3P/6P according IEC61869-11 |
Operating temperature range: | -25°C to +65°C |
Storage temperature range: | -40°C to +80°C |
Frequency: | 50 or 60Hz* |
Overvoltage protection: | Internal surge arrestor |
Cable: |
2pole, shielded, twisted pair, 2m, open ends (brown-a, black-n)* |
Are you interested in this product? Do you need additional information or individual pricing?
The voltage sensor range is designed according the IECstandard to meet maximum combability on the market. This product is designed for use in conjunction with devices, which are build according the standard. The voltage sensor cone shape compatible to different manufacturers of T-cable connectors like Cellpack, Nexans, Südkabel, nkt, Tyco Features No calibration on Site is needed |
Dimensions The short form factor enables maximum compatibility to existing installations. The hexagonal nut is |
Installation |
||
The voltage sensor is simple to install; the existing blind plug
|
![]() |
Connection
The voltage sensor is directly connected to a measurement
|
![]() |
|
M8-Subconnector |
![]() |
Specification | |
---|---|
Applied Standards: | IEC61869-1, IEC61869-6, IEC61869-11 |
Primary voltage: | 20000/√3V* |
Voltage factor | 1,9*Un for 8h |
Secondary output: | 3,25/√3V* |
Burden: | 200kOhm±1%, 350pF* |
Insulation level: | 24/50/125kV |
Accuracy classes: | 0,2/0,5/1/3 [&] 3P/6P according IEC61869-11 |
Operating temperature range: | -25°C to +65°C |
Storage temperature range: | -40°C to +80°C |
Frequency: | 50 or 60Hz* |
Overvoltage protection: | Internal surge arrestor |
Cable: |
2pole, shielded, twisted pair, 2m, open ends (brown-a, black-n)* |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent