Voltage transducer DVC 1000-P

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Features:

  • Bipolar and insulated measurement up to 1500 V
  • Voltage output
  • PCB mount
  • 8 pins
  • 5 V unipolar power supply
 

Advantages:

  • Low consumption and low losses
  • Compact design
  • Very low sensitivity to common mode voltage variations
  • Excellent accuracy (offset, sensitivity, linearity)
  • Low temperature drift
  • High immunity to external interferences

Applications:

  • Single or three phase inverters
  • AC variable speed drives and servo motor drives
  • Static converters for DC motor drives
  • Uninterruptible Power Supplies (UPS)
  • Power supplies for welding applications
  • Auxiliary converters
  • Substations
  • Traction (trackside and onboard)
  • Industrial

Standardy:

  • EN 50155: 2007
  • EN 50121-3-2: 2015
  • EN 50124-1: 2001
  • IEC 61010-1: 2010
  • IEC 61800-1: 1997
  • IEC 61800-2: 2015
  • IEC 61800-3: 2017
  • IEC 61800-5-1: 2007
  • IEC 62109-1: 2010


Electrical data
Primary nominal RMS voltage1000 V
Primary voltage, measuring range±1500 V
Measuring resistance2000 Ω
Secondary nominal RMS voltage3,83 V
Secondary voltage+0,5…+4,5V
Supply voltage5 VDC +/-5%
Current consumption35 mA
Sensitivity1,333 mV/V
Sensitivity error±0,8%
Thermal drift of sensitivity±0,4%
Linearity error±0,2%
Overall accuracy±1%, 25oC; 100 % tested in production;
±1,5%, −40 … 85 °C
Reaction time @ 10 % of VP N1,7 µs
Response time @ 90 % of VP N10 µs
Frequency bandwidth47 kHz (-3 dB)
26 kHz (-1dB)


Environmental and mechanical characteristics
Ambient operating temperature-40oC – 85oC
Ambient storage temperature-50oC – 90oC
Mass22 g


Insulation coordination
RMS voltage for AC insulation test, 50 Hz, 1 min4,2 kV
Impulse withstand voltage 1.2/50 μs7,84 kV
Partial discharge RMS test voltage (qm < 10 pC)1,5 kV
Insulation resistance200 MΩ


Absolute maximum ratings
Maximum supply voltage (VP = 0 V, 0.1 s)6 V
Maximum supply voltage (working) (−40 … 85 oC)5,25 V
Maximum primary voltage (−40 … 85 oC)1500 V
Maximum steady state primary voltage (−40 … 85 oC)1000 V

Dimensions



Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Voltage transducer DVC 1000-P

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Features:

  • Bipolar and insulated measurement up to 1500 V
  • Voltage output
  • PCB mount
  • 8 pins
  • 5 V unipolar power supply
 

Advantages:

  • Low consumption and low losses
  • Compact design
  • Very low sensitivity to common mode voltage variations
  • Excellent accuracy (offset, sensitivity, linearity)
  • Low temperature drift
  • High immunity to external interferences

Applications:

  • Single or three phase inverters
  • AC variable speed drives and servo motor drives
  • Static converters for DC motor drives
  • Uninterruptible Power Supplies (UPS)
  • Power supplies for welding applications
  • Auxiliary converters
  • Substations
  • Traction (trackside and onboard)
  • Industrial

Standardy:

  • EN 50155: 2007
  • EN 50121-3-2: 2015
  • EN 50124-1: 2001
  • IEC 61010-1: 2010
  • IEC 61800-1: 1997
  • IEC 61800-2: 2015
  • IEC 61800-3: 2017
  • IEC 61800-5-1: 2007
  • IEC 62109-1: 2010


Electrical data
Primary nominal RMS voltage1000 V
Primary voltage, measuring range±1500 V
Measuring resistance2000 Ω
Secondary nominal RMS voltage3,83 V
Secondary voltage+0,5…+4,5V
Supply voltage5 VDC +/-5%
Current consumption35 mA
Sensitivity1,333 mV/V
Sensitivity error±0,8%
Thermal drift of sensitivity±0,4%
Linearity error±0,2%
Overall accuracy±1%, 25oC; 100 % tested in production;
±1,5%, −40 … 85 °C
Reaction time @ 10 % of VP N1,7 µs
Response time @ 90 % of VP N10 µs
Frequency bandwidth47 kHz (-3 dB)
26 kHz (-1dB)


Environmental and mechanical characteristics
Ambient operating temperature-40oC – 85oC
Ambient storage temperature-50oC – 90oC
Mass22 g


Insulation coordination
RMS voltage for AC insulation test, 50 Hz, 1 min4,2 kV
Impulse withstand voltage 1.2/50 μs7,84 kV
Partial discharge RMS test voltage (qm < 10 pC)1,5 kV
Insulation resistance200 MΩ


Absolute maximum ratings
Maximum supply voltage (VP = 0 V, 0.1 s)6 V
Maximum supply voltage (working) (−40 … 85 oC)5,25 V
Maximum primary voltage (−40 … 85 oC)1500 V
Maximum steady state primary voltage (−40 … 85 oC)1000 V