Relé de CC EVR400SB
  • Relé de CC EVR400SB

Las fotos son solo para fines informativos. Ver especificaciones de producto

please use latin characters

Fabricante: YM Tech

Relé de CC EVR400SB

  • EVR400SB

Application

  • Battery Energy Storage System
  • Electric Vehicle,
  • Charging System,
  • Solar System,
  • Golf Car
  • Fuel Cell Vehicle
  • etc.

Magnet coil ratings

Nominal voltage(V)Inrush Coil current 100ms (Max.)Holding Coil current (mA)Pick-up voltage (V)Max. (Contact Closing → Opening)Drop-out voltage (V)Min. (Contact Opening → Closing)Holding voltage (V)Min. (Contact:Opening)Max. voltage (V)Max
A 36 3.8A 0.09A 9VDC 6VDC 7.5VDC 36VDC
24 0.13A
12 0.27A
12 3.8A 0.3A 9VDC 6VDC 7.5VDC 18VDC
24 2.7A 0.3A 18VDC 12VDC 13.5VDC 32VDC

Contact ratings

Type1Pole Resistive load (L/R≤1㎳)
Max. Continuous current (wire size 150㎟×2) 500A
Max. switching current 1200V DC 80A UL Certification
1000V DC 90A
1200V DC 80A
1000V DC 100A
Contact rating switching voltages 12~1500VDC
Voltage drop across contacts per 100A 30mV Max
Min. permissible load 12VDC 0.5A
Description S.P On/Off (b)
Contact Arrangement 1Form B (SPST-NC.)

Characteristics

Expected lifeMechanical (Min.)2×106
Electric (L/R≤1㎳) 450V DC 400A 3×103
250V DC 400A 1×105
1000V DC 100A 1×104
Initial insulation resistance Min. 100㏁ 500V DC
Initial breakdown voltage Between open contacts 3500V AC 60 Sec. 5mA
Between contacts & coil 3500V AC 60 Sec. 5mA
Operate time (at 20℃) Max. 30㎳
Release time (at 20℃) Max. 10㎳
Shock resistance Functional Min 196 ㎨ {20G}
Destructive Min 490 ㎨ {50G}
Vibration resistance Functional 100 ㎨ {20G} 80 to 2000㎐
Destructive 100 ㎨ {20G} 80 to 2000㎐
Conditions for operation transport and storage Ambient temperature -40℃ to +85℃
Humidity 5 to 85% R.H.
Unit weight 660g

Envíe una consulta

¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?

Contacta con nosotras
SOLICITA EL PRODUCTO close
Mensaje enviado con éxito.
SOLICITA EL PRODUCTO close
Vistazo

Añadir a la lista de deseos

Usted debe estar conectado

Application

  • Battery Energy Storage System
  • Electric Vehicle,
  • Charging System,
  • Solar System,
  • Golf Car
  • Fuel Cell Vehicle
  • etc.

Magnet coil ratings

Nominal voltage(V)Inrush Coil current 100ms (Max.)Holding Coil current (mA)Pick-up voltage (V)Max. (Contact Closing → Opening)Drop-out voltage (V)Min. (Contact Opening → Closing)Holding voltage (V)Min. (Contact:Opening)Max. voltage (V)Max
A 36 3.8A 0.09A 9VDC 6VDC 7.5VDC 36VDC
24 0.13A
12 0.27A
12 3.8A 0.3A 9VDC 6VDC 7.5VDC 18VDC
24 2.7A 0.3A 18VDC 12VDC 13.5VDC 32VDC

Contact ratings

Type1Pole Resistive load (L/R≤1㎳)
Max. Continuous current (wire size 150㎟×2) 500A
Max. switching current 1200V DC 80A UL Certification
1000V DC 90A
1200V DC 80A
1000V DC 100A
Contact rating switching voltages 12~1500VDC
Voltage drop across contacts per 100A 30mV Max
Min. permissible load 12VDC 0.5A
Description S.P On/Off (b)
Contact Arrangement 1Form B (SPST-NC.)

Characteristics

Expected lifeMechanical (Min.)2×106
Electric (L/R≤1㎳) 450V DC 400A 3×103
250V DC 400A 1×105
1000V DC 100A 1×104
Initial insulation resistance Min. 100㏁ 500V DC
Initial breakdown voltage Between open contacts 3500V AC 60 Sec. 5mA
Between contacts & coil 3500V AC 60 Sec. 5mA
Operate time (at 20℃) Max. 30㎳
Release time (at 20℃) Max. 10㎳
Shock resistance Functional Min 196 ㎨ {20G}
Destructive Min 490 ㎨ {50G}
Vibration resistance Functional 100 ㎨ {20G} 80 to 2000㎐
Destructive 100 ㎨ {20G} 80 to 2000㎐
Conditions for operation transport and storage Ambient temperature -40℃ to +85℃
Humidity 5 to 85% R.H.
Unit weight 660g