![Serie Analizador de IM Serie Analizador de IM](https://www.dacpol.eu/27094-large_default/serie-analizador-de-im.jpg)
![Serie Analizador de IM Serie Analizador de IM](https://www.dacpol.eu/27094-large_default/serie-analizador-de-im.jpg)
Debes estar logueado
Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Las fotos son solo para fines informativos. Ver especificaciones de producto
please use latin characters
The IM series is an on-line multi IR wavelength Mirror type analyzer utilizing the infrared absorption technology for measuring product constituent and/or thickness. Signal processing capabilities are built into the Compact All-In-One detector unit for easy installation and operation. A maximum of 99 calibration curves can be stored into the detector memory for numerous measurement applications. The detector can be used by itself or connected to a PC/plant control system, as both analog and digital outputs are provided. A remote setting display unit, connectable up to 9 detector units, can be used to setup various detector functions and also displays measured values.
Application:
• Measuring moisture of wood chip.
• Measuring the thickness of sheet or film.
• Measuring the organism, moisture and lipid of fodder.
• Measuring the organism, moisture and oil of potato chips.
• Measuring moisture of garbage (RDF moisture).
• Measuring the coating thickness on the painting sheet.
• Measuring moisture of powder.
• Measuring moisture in cleaning solution.
• Measuring moisture of clay.
• Measuring moisture of fiber.
• Measure [&] Control the coating thickness
of Laminate-sheet production line.
• Measure [&] Control the painting thickness.
Features:
• Up to 10 wavelengths, capable of measuring 4 constituents such as; moisture, film-thickness, organism, and coating-thickness in real time simultaneously.
• Connectivity to multiple interfaces, RS485 (MODBUS), Ethernet (LAN)
• High-speed [&] High-repeatability (28ms)
• Multi-calculation function
• Self-diagnostic function, easy maintenance.
• Conforms to CE standards and IP-65
Object | Range | Accu. |
---|---|---|
General moisture (%) | ||
Glass / pottery / cement | ||
Potter's clay | 0...12 | >±0.3 |
Iron / metal | ||
Coal | 0...15 | >±0.2 |
Mix raw material | 0...10 | >±0.2 |
Iron oxide | 0...10 | >±0.2 |
Foods | ||
Starch | 0...25 | >±0.2 |
Bread-crumbs | 0...20 | >±0.2 |
Soybean | 0...15 | >±0.2 |
Milk powder | 0...5 | >±0.2 |
Sugar / salt | 0...2 | >±0.05 |
Flavouring | 0...10 | >±0.2 |
Tea | 0...15 | >±0.2 |
Chemicals | ||
Catalyst | 0...10 | >±0.2 |
Medium | 0...20 | >±0.2 |
Detergent | 0...15 | >±0.2 |
Ink | 0...5 | >±0.2 |
Fertilizer | 0...5 | >±0.2 |
Rubber / fiber / etc. | ||
Vinylon fiber | 0...10 | >±0.2 |
Acrylic fiber | 0...10 | >±0.2 |
Wood chip | 0...10 | >±0.2 |
Paper | 0...10 | >±0.1 |
Material | Range | Accu. |
---|---|---|
Wet paper | 40...70 | >±0.5 |
Raw bread crumbs | 30...40 | >±0.7 |
Clay | 0...30 | >±0.3 |
Silica sand | 0...10 | >±0.8 |
Bicarbonate | 0...18 | >±0.6 |
Micro moisture | ||
ABS, PVC powder | 0...1 | >±0.8 |
Granular ferrite | 0...0.5 | >±0.8 |
Thickness [um] | ||
Polyethylene PE | 10...3000 | >+0.2 |
Polypropylene PP | >±0.2 | |
Polyester PET | >±0.2 | |
Vinyl chloride PVC | >±0.2 | |
PVA | >±0.2 | |
EVA | >±0.2 | |
Polystyrene PS | >+0.2 | |
Polycarbonate | >±0.2 | |
Nylon PA | >±0.2 | |
Polyimide PI | >±0.3 | |
TAC film | >±0.2 | |
Coating (g/m2) | ||
Coat-paper | 10...1000 | |
Tuck-paper, label | ||
Adhesive WET/DRY | ||
Resin on steel-board |
![]() |
Main Screen Displays measured data, trend and alarm value. Displays 4 constituents on one screen. Save data into specified folder, enable to search or read out the data. |
|
![]() |
![]() |
GENERAL SPECIFICATIONS | |
INFRARED MULTI ANALYZER | |
• Measuring system: | Infrared absorption type |
• Measuring wavelength: | Up to 10 wavelengths |
• Measuring component: | Up to 4 constituents |
• Light source: | Tungsten lamp |
• Measuring distance: | 200...400 mm (IRMA 1300:160...300 mm) |
• Measuring diameter: | 50 mm3 / 300 mm (IRMA 1300: 30 mm3/200 mm |
• Analog output: | 4 to 20mADC, ±0.2% of full scale (Load resistance: less than 500Ω) |
• Communications:: | RS485 MODBUS |
• Output renewal cycle: | 28 ms |
• Display [&] setup: | Displays data [&] setup parameter Parameters are configurable by key. |
• Computing:: | 2 or 3-color ratio calculation Multiple regression calculation |
• No. of calibration curve: | Up to 99 curves |
• Calibration curve: | Linear, quadratic, cubic [&] multiple regression line |
• Calibration curve correction: | Linear [&] quadratic co |
• Smoothing (delay): | 0...99 sec |
• Calibration: | By checking plate |
• Detector No. setup: | When multiple detector operation,detector No. is key configurable. |
• Channel No. setup: | Calibration curve No. is key configurable. |
• Self-diagnostic: | Outputs contact signal and communications when abnormal conditions. |
• Correction input: | Compensate measured value by external 4 to 20mA DC (sample temperature, etc.) |
• External Di/o: | Di(contact input) --- Perform either oneof preset, data-hold or real/smoothing Do(contact output) --- Selects self-diagnostic(1b) or Hi/low alarm(1a) |
• Working temperature: | 0 to 50°C (Use dry air cooling if higher than 45°C. Outlet air temperature must be lower than 30°C.) |
• Power supply: | 24V DC supplied from IR-WEP (IR-WEP power supply: 100-240VAC) |
• Power consumption:: | ok. 30 VA |
• Connection: | terminal |
• Casing: | Aluminum casting, drip-proof structure (conforming to IEC529, IP65) |
• Weight: | Approx. 4.3kg |
• Mounting:: | Bolt suspension method with 4 pieces of M8 bolts |
• CE-standards: | EMC directives EN61326+A |
SETTING DISPLAY UNIT | |
•Input signal | RS485, Up to 9 detectors connectable |
• Analog output: | 4 to 20mADC, 2 output* (Load resistance: less than 500Ω) * When multiple detector operation, outputs for detector No. 1 [&] 2. |
• Communications: | RS232C, RS422 or RS485 |
• Output renewal cycle:: | 28ms × detector number |
Display: | 1) Measured data, LED 5-digit |
2) Detector No., CH. No., Parameter setup | |
• Detector No. setup:: | Detector No.1 to No.9 is key configurable. |
• Calibration curve No. setup | Calibration curve No. is key configurable. |
• Smoothing time: | T = 0,0...9,9 s, 10...99S |
• Calibration:: | Perform calibration by key operation or by external contact in use of checking plate |
• Hold/preset: | Hold or preset the display and output by key operation or external contact. |
• Calibration curve correction: | Online correction of calibration curve Linear or quadratic correction. |
• External setup: | Detector No., CH. No., Calibration,Hold or Preset. |
• Alarm function:: | Outputs contact signal (HCL) beyond setting-range |
• Self-diagnostic: | Outputs contact signal(1b) when abnormal condition With lamp display |
• Power supply: | 100...240VAC 50/60 Hz |
• Power consumption: | max. 15 VA |
• Working ambient: | 0...50 °C |
• Casing: | ABS |
• Protection level | IP65 |
• Mounting: | Panel-mount type |
• Weight:: | Approx. 0.6kg |
CE STANDARDS SPECIFICATIONS | |
• Analog output:: | 1x4...20mA |
• Load resistance: | <500n |
• Power supply:: | 24VDC±10% |
• Power consumption: | About 10VA |
FIBER UNIT | |
• Measuring distance and diameter: | With lens --- φ25/25mm to φ40/100mm |
Without lens --- φ20/15mm to φ50/50mm | |
• Długość światłowodów: | Standard 1.5m, Max.5m (Reflection type fiber) |
Standard 2m, Max.10m (Transmission type fiber) | |
• Fiber protection: | Stainless steel flexible armour |
• Minimum bending radius: | r= 100 mm |
• Working temperature: | 0...150°C |
• Purge air flow:: | With lens --- Air purge disabled |
Without lens --- 5 to 20L/min | |
• Accessory:: | Vertical mounting holder |
Flange holder |
Analyzer IRMA
![]() |
Setting display unit IRGMEG2
![]() |
Power supply unit IR-WEP![]() |
Air purge hood IR-WEA
![]() |
Output checking plate IR-WEB
![]() |
Connecting cable IR-WERP
![]() |
Reflection type fiber![]() |
Reflection type fiber (with lens)
IR-WCRE
![]() |
Transmission type fiber
![]() |
Output checking plate for reflection type fiber IR-WCRB ![]() |
Liquid cell IR-WCC
![]() |
Air-cooling box IR-WEX
![]() |
¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?
Usted debe estar conectado
The IM series is an on-line multi IR wavelength Mirror type analyzer utilizing the infrared absorption technology for measuring product constituent and/or thickness. Signal processing capabilities are built into the Compact All-In-One detector unit for easy installation and operation. A maximum of 99 calibration curves can be stored into the detector memory for numerous measurement applications. The detector can be used by itself or connected to a PC/plant control system, as both analog and digital outputs are provided. A remote setting display unit, connectable up to 9 detector units, can be used to setup various detector functions and also displays measured values.
Application:
• Measuring moisture of wood chip.
• Measuring the thickness of sheet or film.
• Measuring the organism, moisture and lipid of fodder.
• Measuring the organism, moisture and oil of potato chips.
• Measuring moisture of garbage (RDF moisture).
• Measuring the coating thickness on the painting sheet.
• Measuring moisture of powder.
• Measuring moisture in cleaning solution.
• Measuring moisture of clay.
• Measuring moisture of fiber.
• Measure [&] Control the coating thickness
of Laminate-sheet production line.
• Measure [&] Control the painting thickness.
Features:
• Up to 10 wavelengths, capable of measuring 4 constituents such as; moisture, film-thickness, organism, and coating-thickness in real time simultaneously.
• Connectivity to multiple interfaces, RS485 (MODBUS), Ethernet (LAN)
• High-speed [&] High-repeatability (28ms)
• Multi-calculation function
• Self-diagnostic function, easy maintenance.
• Conforms to CE standards and IP-65
Object | Range | Accu. |
---|---|---|
General moisture (%) | ||
Glass / pottery / cement | ||
Potter's clay | 0...12 | >±0.3 |
Iron / metal | ||
Coal | 0...15 | >±0.2 |
Mix raw material | 0...10 | >±0.2 |
Iron oxide | 0...10 | >±0.2 |
Foods | ||
Starch | 0...25 | >±0.2 |
Bread-crumbs | 0...20 | >±0.2 |
Soybean | 0...15 | >±0.2 |
Milk powder | 0...5 | >±0.2 |
Sugar / salt | 0...2 | >±0.05 |
Flavouring | 0...10 | >±0.2 |
Tea | 0...15 | >±0.2 |
Chemicals | ||
Catalyst | 0...10 | >±0.2 |
Medium | 0...20 | >±0.2 |
Detergent | 0...15 | >±0.2 |
Ink | 0...5 | >±0.2 |
Fertilizer | 0...5 | >±0.2 |
Rubber / fiber / etc. | ||
Vinylon fiber | 0...10 | >±0.2 |
Acrylic fiber | 0...10 | >±0.2 |
Wood chip | 0...10 | >±0.2 |
Paper | 0...10 | >±0.1 |
Material | Range | Accu. |
---|---|---|
Wet paper | 40...70 | >±0.5 |
Raw bread crumbs | 30...40 | >±0.7 |
Clay | 0...30 | >±0.3 |
Silica sand | 0...10 | >±0.8 |
Bicarbonate | 0...18 | >±0.6 |
Micro moisture | ||
ABS, PVC powder | 0...1 | >±0.8 |
Granular ferrite | 0...0.5 | >±0.8 |
Thickness [um] | ||
Polyethylene PE | 10...3000 | >+0.2 |
Polypropylene PP | >±0.2 | |
Polyester PET | >±0.2 | |
Vinyl chloride PVC | >±0.2 | |
PVA | >±0.2 | |
EVA | >±0.2 | |
Polystyrene PS | >+0.2 | |
Polycarbonate | >±0.2 | |
Nylon PA | >±0.2 | |
Polyimide PI | >±0.3 | |
TAC film | >±0.2 | |
Coating (g/m2) | ||
Coat-paper | 10...1000 | |
Tuck-paper, label | ||
Adhesive WET/DRY | ||
Resin on steel-board |
![]() |
Main Screen Displays measured data, trend and alarm value. Displays 4 constituents on one screen. Save data into specified folder, enable to search or read out the data. |
|
![]() |
![]() |
GENERAL SPECIFICATIONS | |
INFRARED MULTI ANALYZER | |
• Measuring system: | Infrared absorption type |
• Measuring wavelength: | Up to 10 wavelengths |
• Measuring component: | Up to 4 constituents |
• Light source: | Tungsten lamp |
• Measuring distance: | 200...400 mm (IRMA 1300:160...300 mm) |
• Measuring diameter: | 50 mm3 / 300 mm (IRMA 1300: 30 mm3/200 mm |
• Analog output: | 4 to 20mADC, ±0.2% of full scale (Load resistance: less than 500Ω) |
• Communications:: | RS485 MODBUS |
• Output renewal cycle: | 28 ms |
• Display [&] setup: | Displays data [&] setup parameter Parameters are configurable by key. |
• Computing:: | 2 or 3-color ratio calculation Multiple regression calculation |
• No. of calibration curve: | Up to 99 curves |
• Calibration curve: | Linear, quadratic, cubic [&] multiple regression line |
• Calibration curve correction: | Linear [&] quadratic co |
• Smoothing (delay): | 0...99 sec |
• Calibration: | By checking plate |
• Detector No. setup: | When multiple detector operation,detector No. is key configurable. |
• Channel No. setup: | Calibration curve No. is key configurable. |
• Self-diagnostic: | Outputs contact signal and communications when abnormal conditions. |
• Correction input: | Compensate measured value by external 4 to 20mA DC (sample temperature, etc.) |
• External Di/o: | Di(contact input) --- Perform either oneof preset, data-hold or real/smoothing Do(contact output) --- Selects self-diagnostic(1b) or Hi/low alarm(1a) |
• Working temperature: | 0 to 50°C (Use dry air cooling if higher than 45°C. Outlet air temperature must be lower than 30°C.) |
• Power supply: | 24V DC supplied from IR-WEP (IR-WEP power supply: 100-240VAC) |
• Power consumption:: | ok. 30 VA |
• Connection: | terminal |
• Casing: | Aluminum casting, drip-proof structure (conforming to IEC529, IP65) |
• Weight: | Approx. 4.3kg |
• Mounting:: | Bolt suspension method with 4 pieces of M8 bolts |
• CE-standards: | EMC directives EN61326+A |
SETTING DISPLAY UNIT | |
•Input signal | RS485, Up to 9 detectors connectable |
• Analog output: | 4 to 20mADC, 2 output* (Load resistance: less than 500Ω) * When multiple detector operation, outputs for detector No. 1 [&] 2. |
• Communications: | RS232C, RS422 or RS485 |
• Output renewal cycle:: | 28ms × detector number |
Display: | 1) Measured data, LED 5-digit |
2) Detector No., CH. No., Parameter setup | |
• Detector No. setup:: | Detector No.1 to No.9 is key configurable. |
• Calibration curve No. setup | Calibration curve No. is key configurable. |
• Smoothing time: | T = 0,0...9,9 s, 10...99S |
• Calibration:: | Perform calibration by key operation or by external contact in use of checking plate |
• Hold/preset: | Hold or preset the display and output by key operation or external contact. |
• Calibration curve correction: | Online correction of calibration curve Linear or quadratic correction. |
• External setup: | Detector No., CH. No., Calibration,Hold or Preset. |
• Alarm function:: | Outputs contact signal (HCL) beyond setting-range |
• Self-diagnostic: | Outputs contact signal(1b) when abnormal condition With lamp display |
• Power supply: | 100...240VAC 50/60 Hz |
• Power consumption: | max. 15 VA |
• Working ambient: | 0...50 °C |
• Casing: | ABS |
• Protection level | IP65 |
• Mounting: | Panel-mount type |
• Weight:: | Approx. 0.6kg |
CE STANDARDS SPECIFICATIONS | |
• Analog output:: | 1x4...20mA |
• Load resistance: | <500n |
• Power supply:: | 24VDC±10% |
• Power consumption: | About 10VA |
FIBER UNIT | |
• Measuring distance and diameter: | With lens --- φ25/25mm to φ40/100mm |
Without lens --- φ20/15mm to φ50/50mm | |
• Długość światłowodów: | Standard 1.5m, Max.5m (Reflection type fiber) |
Standard 2m, Max.10m (Transmission type fiber) | |
• Fiber protection: | Stainless steel flexible armour |
• Minimum bending radius: | r= 100 mm |
• Working temperature: | 0...150°C |
• Purge air flow:: | With lens --- Air purge disabled |
Without lens --- 5 to 20L/min | |
• Accessory:: | Vertical mounting holder |
Flange holder |
Analyzer IRMA
![]() |
Setting display unit IRGMEG2
![]() |
Power supply unit IR-WEP![]() |
Air purge hood IR-WEA
![]() |
Output checking plate IR-WEB
![]() |
Connecting cable IR-WERP
![]() |
Reflection type fiber![]() |
Reflection type fiber (with lens)
IR-WCRE
![]() |
Transmission type fiber
![]() |
Output checking plate for reflection type fiber IR-WCRB ![]() |
Liquid cell IR-WCC
![]() |
Air-cooling box IR-WEX
![]() |
Su agradecimiento a la reseña no pudo ser enviado
Reportar comentario
Reporte enviado
Su reporte no pudo ser enviado
Escriba su propia reseña
Reseña enviada
Su reseña no pudo ser enviada