Non-invasive current measurement | ||
---|---|---|
MODEL |
CP1000 |
CP1005 |
Current Range | 1000A DC lub AC RMS | 100 / 1000A DC lub AC RMS |
Output Sensitivity | 1mV/A | 10 / 1mV/A |
Resolution | ± 500mA | ±100mA / ±500mA |
Basic Accuracy | ± 1% reading ± 0.5A | ± 1% reading ± 0.1A / ± 0.5A |
Conductor position sensitivity | < ± 1% relative to centre reading | |
Frequency Range (-3dB) | 10kHz | 20kHz |
Phase shift (up to 1kHz) | N/A | < 2 degress |
Load Impedance | > 100 kΩ | |
Output connection | Safety 4mm plugs | Safety BNC / connector 4mm |
ENVIRONMENTAL DATA
|
|
Operating Temperature
|
0°C do 50°C
|
Temp. Coefficient
|
± 0.15% of reading per°C |
Storage Temperature (without battery)
|
-20°C do 85°C
|
POWER SUPPLY
|
|
Battery type
|
9v Alkaline: MN1604, PP3 IEC 6LR61 or equivalent
|
Battery life
|
50 hours typical
|
MECHANICAL DATA
|
|
Dimensions (mm)
|
200 (W) x 74 (S) x 25 (G)
|
Jaw Capacity
|
32mm Ø |
Weight
|
320g
|
SAFETY
|
|
EN61010-2-032:2002,
300V, Measurement Category III, Pollution Degree 2. |
|
MAXIMUM SAFE VOLTAGES
|
|
300V AC RMS or DC between uninsulated conductor and ground
|
|
EMC Standard EN 61326-2-2:2006
|
|
All accuracies stated at 23°C ± 1°C (73.4°F ± 1.8°F)
|
High Accuracy with Superior External Field Rejection
Advanced magnetic circuit design results in probes accuracy to be little affected by external magneticfields
or off-centre conductor positioning.
EN61010-2-032:2002 and EMC Conformance
Safety features including a tactile barrier and special jaw design provide the user with confidence when making measurements in hazardous voltage areas.
Conformance to EMC standards ensures high reliability through reduced susceptibility to electromagnetic interference.
Catalog number
|
Output type
|
---|---|
CP1000 |
BNC
|
CP1005 |
BNC
|
CP1005_4mm |
4mm
|
¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?
Usted debe estar conectado
Non-invasive current measurement | ||
---|---|---|
MODEL |
CP1000 |
CP1005 |
Current Range | 1000A DC lub AC RMS | 100 / 1000A DC lub AC RMS |
Output Sensitivity | 1mV/A | 10 / 1mV/A |
Resolution | ± 500mA | ±100mA / ±500mA |
Basic Accuracy | ± 1% reading ± 0.5A | ± 1% reading ± 0.1A / ± 0.5A |
Conductor position sensitivity | < ± 1% relative to centre reading | |
Frequency Range (-3dB) | 10kHz | 20kHz |
Phase shift (up to 1kHz) | N/A | < 2 degress |
Load Impedance | > 100 kΩ | |
Output connection | Safety 4mm plugs | Safety BNC / connector 4mm |
ENVIRONMENTAL DATA
|
|
Operating Temperature
|
0°C do 50°C
|
Temp. Coefficient
|
± 0.15% of reading per°C |
Storage Temperature (without battery)
|
-20°C do 85°C
|
POWER SUPPLY
|
|
Battery type
|
9v Alkaline: MN1604, PP3 IEC 6LR61 or equivalent
|
Battery life
|
50 hours typical
|
MECHANICAL DATA
|
|
Dimensions (mm)
|
200 (W) x 74 (S) x 25 (G)
|
Jaw Capacity
|
32mm Ø |
Weight
|
320g
|
SAFETY
|
|
EN61010-2-032:2002,
300V, Measurement Category III, Pollution Degree 2. |
|
MAXIMUM SAFE VOLTAGES
|
|
300V AC RMS or DC between uninsulated conductor and ground
|
|
EMC Standard EN 61326-2-2:2006
|
|
All accuracies stated at 23°C ± 1°C (73.4°F ± 1.8°F)
|
High Accuracy with Superior External Field Rejection
Advanced magnetic circuit design results in probes accuracy to be little affected by external magneticfields
or off-centre conductor positioning.
EN61010-2-032:2002 and EMC Conformance
Safety features including a tactile barrier and special jaw design provide the user with confidence when making measurements in hazardous voltage areas.
Conformance to EMC standards ensures high reliability through reduced susceptibility to electromagnetic interference.
Catalog number
|
Output type
|
---|---|
CP1000 |
BNC
|
CP1005 |
BNC
|
CP1005_4mm |
4mm
|
Su agradecimiento a la reseña no pudo ser enviado
Reportar comentario
Reporte enviado
Su reporte no pudo ser enviado
Escriba su propia reseña
Reseña enviada
Su reseña no pudo ser enviada