Módulo DIFIODOWO - PODER
  • Módulo DIFIODOWO - PODER

Las fotos son solo para fines informativos. Ver especificaciones de producto

please use latin characters

Fabricante: DACPOL

Módulo DIFIODOWO - PODER

Two element diode power block with water radiator

Properties:
• Two element diode power block with water radiator
• Water cooling

Typical applications:
• rectifiers,
• power supplies


Options:
• clamp assembled K-1 – Drawing. 1
• clamp assembled K-2 – Drawing. 2
• clamp assembled K-3 – Drawing. 3
• Thermal protection
• RC circuit
• fuse


Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.


Operation conditions:
One element power blocks are used in power electronic systems
• Cooling water temperature 50 C do 300 C at ambient air temperature > -100 C
• Atmospheric pressure  860hPa do 1060hPa

Drawing 1
Drawing 2
Drawing 3

 

 
 
 
Table 1 Power blocks parameters
 

Module type Mean current  IF(AV) [A] Blocking voltage  U RRM
    [V]
Overcurrent
I FSM
[A]
Semiconductor size
[mm]
Block Weight 
[kg]
MOC75W 800…1400 400…2200 8000… 12000 1,4
MOC7W 450…650 400…3000 7000…10000 1,6
MOC8W 630…1000 400…6000 10000…24000 1,6
MOC9W 1000…3000 400…6000 20000…42000 3,2
MOC11W 2000…4000 400…7200 27000…65000 9,8

 
Power block scheme MOD..W
Scheme
 

Envíe una consulta

¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?

Contacta con nosotras
SOLICITA EL PRODUCTO close
Gracias por enviar tu mensaje. Responderemos lo antes posible.
SOLICITA EL PRODUCTO close
Vistazo

Añadir a la lista de deseos

Usted debe estar conectado

Two element diode power block with water radiator

Properties:
• Two element diode power block with water radiator
• Water cooling

Typical applications:
• rectifiers,
• power supplies


Options:
• clamp assembled K-1 – Drawing. 1
• clamp assembled K-2 – Drawing. 2
• clamp assembled K-3 – Drawing. 3
• Thermal protection
• RC circuit
• fuse


Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.


Operation conditions:
One element power blocks are used in power electronic systems
• Cooling water temperature 50 C do 300 C at ambient air temperature > -100 C
• Atmospheric pressure  860hPa do 1060hPa

Drawing 1
Drawing 2
Drawing 3

 

 
 
 
Table 1 Power blocks parameters
 

Module type Mean current  IF(AV) [A] Blocking voltage  U RRM
    [V]
Overcurrent
I FSM
[A]
Semiconductor size
[mm]
Block Weight 
[kg]
MOC75W 800…1400 400…2200 8000… 12000 1,4
MOC7W 450…650 400…3000 7000…10000 1,6
MOC8W 630…1000 400…6000 10000…24000 1,6
MOC9W 1000…3000 400…6000 20000…42000 3,2
MOC11W 2000…4000 400…7200 27000…65000 9,8

 
Power block scheme MOD..W
Scheme
 
Comentarios (0)