RF Admittance Level Transmitter
  • RF Admittance Level Transmitter

Las fotos son solo para fines informativos. Ver especificaciones de producto

please use latin characters

Fabricante: FineTek

RF Admittance Level Transmitter

The RF admittance level transmitter uses the capacitance formed between the measuring probe and the reference probe or the metal tank wall to calculate the level of the medium inside the tank based on capacitance theory, where capacitance and tank volume are proportionally increased. When the probe is surrounded by air, a small capacitance (C) is measured by the equivalent capacitor A. The capacitance gradually increases as the medium fills, and the maximum capacitance (C) is measured by capacitor B when the tank is full. The difference (dC) between C and C is proportional to the level between A and B (recommended range for dC = 25-2000 pF).

Main features:

  • 4-20mA, 2-wire, loop powered
  • Low power consumption (max. 20 mA)
  • High accuracy linearity (temperature compensation, low-temperature effect (A0.2% FS/BC or 0.1pF/BC))
  • Easy calibration (2 arbitrary calibration points)
  • No minimum distance from the liquid, ideal for various tanks
  • Suitable for high temperature, high pressure, and corrosive environments
  • Local LCD display

Applications:

  • Aqueous solutions
  • Oils
  • Acids or bases
  • Animal feed and grains
  • Mining and cement

Envíe una consulta

¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?

Contacta con nosotras
SOLICITA EL PRODUCTO close
Gracias por enviar tu mensaje. Responderemos lo antes posible.
SOLICITA EL PRODUCTO close
Vistazo

Añadir a la lista de deseos

Usted debe estar conectado

The RF admittance level transmitter uses the capacitance formed between the measuring probe and the reference probe or the metal tank wall to calculate the level of the medium inside the tank based on capacitance theory, where capacitance and tank volume are proportionally increased. When the probe is surrounded by air, a small capacitance (C) is measured by the equivalent capacitor A. The capacitance gradually increases as the medium fills, and the maximum capacitance (C) is measured by capacitor B when the tank is full. The difference (dC) between C and C is proportional to the level between A and B (recommended range for dC = 25-2000 pF).

Main features:

  • 4-20mA, 2-wire, loop powered
  • Low power consumption (max. 20 mA)
  • High accuracy linearity (temperature compensation, low-temperature effect (A0.2% FS/BC or 0.1pF/BC))
  • Easy calibration (2 arbitrary calibration points)
  • No minimum distance from the liquid, ideal for various tanks
  • Suitable for high temperature, high pressure, and corrosive environments
  • Local LCD display

Applications:

  • Aqueous solutions
  • Oils
  • Acids or bases
  • Animal feed and grains
  • Mining and cement
Comentarios (0)