Features:

  • Proportional or On-Off Electric Linear Actuator 
  • Self-Calibration using the auto setting button
  • Digit indicator (FND and LED lamp)
  • Vary options available
  • Local/Remote control unit
  • Integral motor starter
  • Additional limit switch for feedback
  • Position transmitter etc
  • Perfect enclosure(IP67) against rain, water, moisture or dust.
  • Simple [&] easy manual override with handle-wheel
  • Selectable input signal 4~20mA , 0-10VDC or 2-10VDC
  • Applied into Heating, Ventilation, Air conditioning or Ice thermal storage system


Technical data

Item GEA-55PDW GEA-100PDW
Nominal Stroke (mm) 70mm
Nominal Force (KN) 5500N (5.5)  10000N (10.0) 
Operating Time (Sec) 54s (1.3mm/s) 
Power Supply (V) 24 or 220VAC /1Ph± 10%, 380 or 440VAC/3Ph
Operating mode Modulating or On-Off
Input Signal 4~20mA, 0-10VDC or 2-10VDC
Output Signal Same as input signal
Operation Temperature -15 ~ 70℃
Humidity 5 ~ 95% Rh 5 ~ 95% Rh
Enclosure IP67 (IP68 opcjonalnie) 
Conduit Entries PF1/2x 2EA 

Envíe una consulta

¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?

Contacta con nosotras
SOLICITA EL PRODUCTO close
Gracias por enviar tu mensaje. Responderemos lo antes posible.
SOLICITA EL PRODUCTO close
Vistazo

Añadir a la lista de deseos

Usted debe estar conectado


Features:

  • Proportional or On-Off Electric Linear Actuator 
  • Self-Calibration using the auto setting button
  • Digit indicator (FND and LED lamp)
  • Vary options available
  • Local/Remote control unit
  • Integral motor starter
  • Additional limit switch for feedback
  • Position transmitter etc
  • Perfect enclosure(IP67) against rain, water, moisture or dust.
  • Simple [&] easy manual override with handle-wheel
  • Selectable input signal 4~20mA , 0-10VDC or 2-10VDC
  • Applied into Heating, Ventilation, Air conditioning or Ice thermal storage system


Technical data

Item GEA-55PDW GEA-100PDW
Nominal Stroke (mm) 70mm
Nominal Force (KN) 5500N (5.5)  10000N (10.0) 
Operating Time (Sec) 54s (1.3mm/s) 
Power Supply (V) 24 or 220VAC /1Ph± 10%, 380 or 440VAC/3Ph
Operating mode Modulating or On-Off
Input Signal 4~20mA, 0-10VDC or 2-10VDC
Output Signal Same as input signal
Operation Temperature -15 ~ 70℃
Humidity 5 ~ 95% Rh 5 ~ 95% Rh
Enclosure IP67 (IP68 opcjonalnie) 
Conduit Entries PF1/2x 2EA 