Han-Power® S | ||||
---|---|---|---|---|
Power supply | 1 x Q 4/2 | 1 x Q 4/2 | 2 x Q 4/2 | 1 x Q 8/0 |
Power supply | IDC Insulation displacement terminal | IDC Insulation displacement terminal | IDC Insulation displacement terminal | IDC Insulation displacement terminal |
![]() |
![]() |
![]() |
![]() |
|
Electrical data acc. to EN 61 984 Power contacts |
40 A 400/690 V 6 kV 3 |
40 A 400/690 V 6 kV 3 |
40 A 400/690 V 6 kV 3 |
25 A 500 V 6 kV 3 |
Signal contacts | 10 A 250 V 4 kV | 10 A 250 V 4 kV | 10 A 250 V 4 kV | - |
Wire gauge | 2,5 ... 4 mm2 | 4 ... 6 mm2 | 4 ... 6 mm2 | 2,5 ... 4 mm2 |
Identification of contacts | 1-7 | 1-7 | 1-7 | 1-7 |
Part number | 09 12 008 4804 | 09 12 008 4806 | 09 12 008 4807 | 09 12 008 4801 |
Power supply | 1 x Q 8/0 | 2 x Q 8/0 | 1 x Q 4/2 | 1 x Q 4/2 |
Power supply | IDC Insulation displacement terminal | IDC Insulation displacement terminal | IDC Insulation displacement terminal | IDC Insulation displacement terminal |
![]() |
![]() |
![]() |
![]() |
|
Electrical data acc. to EN 61 984 Power contacts |
25 A 500 V 6 kV 3 |
25 A 500 V 6 kV 3 |
40 A 400/690 V 6 kV 3 |
40 A 400/690 V 6 kV 3 |
Signal contacts | - | - | 10 A 250 V 4 kV | 10 A 250 V 4 kV |
Wire gauge | 4 ... 6 mm2 | 2,5 ... 4 mm2 | 4 ... 6 mm2 | 10 mm2 |
Identification of contacts | 1-7 | 1-7 | 1-7 | 1-5 |
Part number | 09 12 008 4811 | 09 12 008 4802 | 09 12 008 4901 | 09 12 008 4951 |
Han-Power®S Akcesoria | ||||||
---|---|---|---|---|---|---|
Identification | Uszczelnienie przelotu przez panel |
Uszczelnienie przelotu przez panel |
Uszczelnienie przelotu przez panel |
Uszczelnienie przelotu przez panel |
Uszczelnienie przelotu przez panel |
Zaślepka wkręcana |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
Cable diameter | 7 - 10 mm | 10 - 13 mm | 13 - 16 mm | 16 - 19 mm | 19 - 22 mm | |
Bestell-Nummer | 09 12 000 9969 | 09 12 000 9970 | 09 12 000 9971 | 09 12 000 9972 | 09 12 000 9973 | 09 12 000 9974 |
Han-Power® T | |||
---|---|---|---|
Power supply | 3 x Q 4/2 | 3 x Q 5/0 | 3 x Q 3/4 |
Power supply | Crimp terminal | Crimp terminal | Crimp terminal |
![]() |
![]() |
![]() |
|
Electrical data acc. to EN 61 984 Power contacts |
40 A 400/690 V 6 kV 3 |
16 A 230/400 V 4 kV 3 |
40 A 400/690 V 6 kV 3 |
Signal contacts | 10 A 250 V 4 kV | - | 16 A 400 V 6 kV |
Wire gauge | 4 ... 6 mm2 | 0,14 ... 2,5 mm2 | 2,5 ... 6 mm2 |
Identification of contacts | 04-sty | 05-sty | 07-sty |
Part number | 09 12 008 4720 | 09 12 008 4751 | 09 12 008 4760 |
¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?
Usted debe estar conectado
Han-Power® S | ||||
---|---|---|---|---|
Power supply | 1 x Q 4/2 | 1 x Q 4/2 | 2 x Q 4/2 | 1 x Q 8/0 |
Power supply | IDC Insulation displacement terminal | IDC Insulation displacement terminal | IDC Insulation displacement terminal | IDC Insulation displacement terminal |
![]() |
![]() |
![]() |
![]() |
|
Electrical data acc. to EN 61 984 Power contacts |
40 A 400/690 V 6 kV 3 |
40 A 400/690 V 6 kV 3 |
40 A 400/690 V 6 kV 3 |
25 A 500 V 6 kV 3 |
Signal contacts | 10 A 250 V 4 kV | 10 A 250 V 4 kV | 10 A 250 V 4 kV | - |
Wire gauge | 2,5 ... 4 mm2 | 4 ... 6 mm2 | 4 ... 6 mm2 | 2,5 ... 4 mm2 |
Identification of contacts | 1-7 | 1-7 | 1-7 | 1-7 |
Part number | 09 12 008 4804 | 09 12 008 4806 | 09 12 008 4807 | 09 12 008 4801 |
Power supply | 1 x Q 8/0 | 2 x Q 8/0 | 1 x Q 4/2 | 1 x Q 4/2 |
Power supply | IDC Insulation displacement terminal | IDC Insulation displacement terminal | IDC Insulation displacement terminal | IDC Insulation displacement terminal |
![]() |
![]() |
![]() |
![]() |
|
Electrical data acc. to EN 61 984 Power contacts |
25 A 500 V 6 kV 3 |
25 A 500 V 6 kV 3 |
40 A 400/690 V 6 kV 3 |
40 A 400/690 V 6 kV 3 |
Signal contacts | - | - | 10 A 250 V 4 kV | 10 A 250 V 4 kV |
Wire gauge | 4 ... 6 mm2 | 2,5 ... 4 mm2 | 4 ... 6 mm2 | 10 mm2 |
Identification of contacts | 1-7 | 1-7 | 1-7 | 1-5 |
Part number | 09 12 008 4811 | 09 12 008 4802 | 09 12 008 4901 | 09 12 008 4951 |
Han-Power®S Akcesoria | ||||||
---|---|---|---|---|---|---|
Identification | Uszczelnienie przelotu przez panel |
Uszczelnienie przelotu przez panel |
Uszczelnienie przelotu przez panel |
Uszczelnienie przelotu przez panel |
Uszczelnienie przelotu przez panel |
Zaślepka wkręcana |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
Cable diameter | 7 - 10 mm | 10 - 13 mm | 13 - 16 mm | 16 - 19 mm | 19 - 22 mm | |
Bestell-Nummer | 09 12 000 9969 | 09 12 000 9970 | 09 12 000 9971 | 09 12 000 9972 | 09 12 000 9973 | 09 12 000 9974 |
Han-Power® T | |||
---|---|---|---|
Power supply | 3 x Q 4/2 | 3 x Q 5/0 | 3 x Q 3/4 |
Power supply | Crimp terminal | Crimp terminal | Crimp terminal |
![]() |
![]() |
![]() |
|
Electrical data acc. to EN 61 984 Power contacts |
40 A 400/690 V 6 kV 3 |
16 A 230/400 V 4 kV 3 |
40 A 400/690 V 6 kV 3 |
Signal contacts | 10 A 250 V 4 kV | - | 16 A 400 V 6 kV |
Wire gauge | 4 ... 6 mm2 | 0,14 ... 2,5 mm2 | 2,5 ... 6 mm2 |
Identification of contacts | 04-sty | 05-sty | 07-sty |
Part number | 09 12 008 4720 | 09 12 008 4751 | 09 12 008 4760 |