![Phoenix Ve.Direct 250VA-500VA INVERTERS Phoenix Ve.Direct 250VA-500VA INVERTERS](https://www.dacpol.eu/8868-large_default/phoenix-vedirect-250va-500va-inverters.jpg)
![Phoenix Ve.Direct 250VA-500VA INVERTERS Phoenix Ve.Direct 250VA-500VA INVERTERS](https://www.dacpol.eu/8868-large_default/phoenix-vedirect-250va-500va-inverters.jpg)
Debes estar logueado
Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Las fotos son solo para fines informativos. Ver especificaciones de producto
please use latin characters
![]() |
![]() |
Phoenix 12/375 VE.Direct | Phoenix 12/375 VE.Direct |
VE.Direct communication port:
The VE.Direct port can be connected to:
Fully configurable:
Monitoring:
![]() |
![]() |
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years. The inverters are short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset value. Once in standby the inverter will switch on for a short period (adjustable, default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
Available with different output sockets
Schuko | UK | AU/NZ | EC-320 |
![]() |
![]() |
![]() |
![]() |
Phoenix Inverter |
12V 24V 48V |
12/250 24/250 48/250 |
12/375 24/375 48/375 |
12/500 24/500 48/500 |
---|---|---|---|---|
Cont. power at 25°C | 250VA | 375VA | 500VA | |
Cont. power at 25°C/40°C | 200W/175W | 300W/260W | 400W/350W | |
Peak power | 400W | 700W | 900W | |
Output AC voltage/ frequency (adjustable) | 230VAC ±3%, 50Hz or 60Hz ±0,1% | |||
Input voltage range | 9,2V-17V / 18,4V-34V / 36,8V-62V | |||
DC low shut down (adjustable) | 9,3V / 18,6V / 37,2V Dynamic cut-off, see |
|||
DC low restart and alarm (adjustable) | 10,9V / 21,8V / 43,6V | |||
Battery charged detect (adjustable) | 14V / 28V / 56V | |||
Max. efficiency | 87% / 88% / 88% | 89% / 89% / 90% | 90% / 90% / 91% | |
Zero-load power | 4,2W/ 5,2W / 7,9W | 5,6W / 6,1W / 8,5W | 6W / 6,5W / 9W | |
Default zero-load power in ECO mode (default rety interval: 2.5s ,adjustable) | 0,8W / 1,3W / 2,5W | 0,9W / 1,4W / 2,6W | 1W / 1,5W / 3W | |
Protection | Protection key: output short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, DC ripple too high | |||
Operating temperature range | -40°C ÷ +65°C (derate 1,25% per °C above 25°C) | |||
Humidity (non-condesing) | 95% | |||
Material [&] Colour | Steel chassis and plastic cober (blue Ral 5012) | |||
Battery-connection | Screw terminals | |||
Maximum cable cross-section | 10mm2 / AWG8 | |||
Standard AC outlets | Schuko (CEE 7/4), IEC-320 (male plug icluded), UK (BS 1363), AU/NZ (AS/NZS 3112) | |||
Protection category | IP21 | |||
Weight | 2,4kg | 3kg | 3,9kg | |
Dimensions | 86/165/260mm | 86/165/260mm | 86/172/275mm | |
Normy | EN/IEC60335-1, EN/IEC62109-1, EN55014-1, EN55014-2, IEC61000-6-1, IEC61000-6-3, 3004/104/EC, EN50498 |
¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?
Usted debe estar conectado
![]() |
![]() |
Phoenix 12/375 VE.Direct | Phoenix 12/375 VE.Direct |
VE.Direct communication port:
The VE.Direct port can be connected to:
Fully configurable:
Monitoring:
![]() |
![]() |
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years. The inverters are short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset value. Once in standby the inverter will switch on for a short period (adjustable, default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
Available with different output sockets
Schuko | UK | AU/NZ | EC-320 |
![]() |
![]() |
![]() |
![]() |
Phoenix Inverter |
12V 24V 48V |
12/250 24/250 48/250 |
12/375 24/375 48/375 |
12/500 24/500 48/500 |
---|---|---|---|---|
Cont. power at 25°C | 250VA | 375VA | 500VA | |
Cont. power at 25°C/40°C | 200W/175W | 300W/260W | 400W/350W | |
Peak power | 400W | 700W | 900W | |
Output AC voltage/ frequency (adjustable) | 230VAC ±3%, 50Hz or 60Hz ±0,1% | |||
Input voltage range | 9,2V-17V / 18,4V-34V / 36,8V-62V | |||
DC low shut down (adjustable) | 9,3V / 18,6V / 37,2V Dynamic cut-off, see |
|||
DC low restart and alarm (adjustable) | 10,9V / 21,8V / 43,6V | |||
Battery charged detect (adjustable) | 14V / 28V / 56V | |||
Max. efficiency | 87% / 88% / 88% | 89% / 89% / 90% | 90% / 90% / 91% | |
Zero-load power | 4,2W/ 5,2W / 7,9W | 5,6W / 6,1W / 8,5W | 6W / 6,5W / 9W | |
Default zero-load power in ECO mode (default rety interval: 2.5s ,adjustable) | 0,8W / 1,3W / 2,5W | 0,9W / 1,4W / 2,6W | 1W / 1,5W / 3W | |
Protection | Protection key: output short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, DC ripple too high | |||
Operating temperature range | -40°C ÷ +65°C (derate 1,25% per °C above 25°C) | |||
Humidity (non-condesing) | 95% | |||
Material [&] Colour | Steel chassis and plastic cober (blue Ral 5012) | |||
Battery-connection | Screw terminals | |||
Maximum cable cross-section | 10mm2 / AWG8 | |||
Standard AC outlets | Schuko (CEE 7/4), IEC-320 (male plug icluded), UK (BS 1363), AU/NZ (AS/NZS 3112) | |||
Protection category | IP21 | |||
Weight | 2,4kg | 3kg | 3,9kg | |
Dimensions | 86/165/260mm | 86/165/260mm | 86/172/275mm | |
Normy | EN/IEC60335-1, EN/IEC62109-1, EN55014-1, EN55014-2, IEC61000-6-1, IEC61000-6-3, 3004/104/EC, EN50498 |
Su agradecimiento a la reseña no pudo ser enviado
Reportar comentario
Reporte enviado
Su reporte no pudo ser enviado
Escriba su propia reseña
Reseña enviada
Su reseña no pudo ser enviada