J2140A - Silenciador de señal
  • J2140A - Silenciador de señal

Las fotos son solo para fines informativos. Ver especificaciones de producto

please use latin characters

Fabricante: Picotest

J2140A - Silenciador de señal

J2140A Attenuator

There are two common uses for attenuators when used in conjunction with the network analyzer. One is to attenuate the oscillator source signal. While this may seem odd, one of the most common errors in analyzer measurements is using a source signal that is too large. Even though the analyzer allows setting of the signal output amplitude, the lowest setting is often too high to allow an accurate small-signal measurement to be made. The correct amplitude is the smallest amplitude that exceeds the noise floor.

 

Attenuators are also useful for improving the dynamic range of the measurement. In some cases, as in measuring the open loop gain of an opamp as one example, the low frequency loop gain will be extremely large (100dB or more is not uncommon). Attenuating the output signal increases the effective range of the measurement.

Key features:

  • Integrated unit includes 40dB, 20dB and 10dB
  • Cascade for greater attenuation
  • Improve noise floor or assure small signal measurement

Rated data:

Maximum input level 20dBm
3dB Frequency range DC…50MHz
Maximum VSWR 1.3
Attenuation accuracy 0.2
Dimensions 109x90x51mm
Weight 0.238kg
Input BNC
Output BNC

Envíe una consulta

¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?

Contacta con nosotras
SOLICITA EL PRODUCTO close
Gracias por enviar tu mensaje. Responderemos lo antes posible.
SOLICITA EL PRODUCTO close
Vistazo

Añadir a la lista de deseos

Usted debe estar conectado

J2140A Attenuator

There are two common uses for attenuators when used in conjunction with the network analyzer. One is to attenuate the oscillator source signal. While this may seem odd, one of the most common errors in analyzer measurements is using a source signal that is too large. Even though the analyzer allows setting of the signal output amplitude, the lowest setting is often too high to allow an accurate small-signal measurement to be made. The correct amplitude is the smallest amplitude that exceeds the noise floor.

 

Attenuators are also useful for improving the dynamic range of the measurement. In some cases, as in measuring the open loop gain of an opamp as one example, the low frequency loop gain will be extremely large (100dB or more is not uncommon). Attenuating the output signal increases the effective range of the measurement.

Key features:

  • Integrated unit includes 40dB, 20dB and 10dB
  • Cascade for greater attenuation
  • Improve noise floor or assure small signal measurement

Rated data:

Maximum input level 20dBm
3dB Frequency range DC…50MHz
Maximum VSWR 1.3
Attenuation accuracy 0.2
Dimensions 109x90x51mm
Weight 0.238kg
Input BNC
Output BNC