![Analizador de los parámetros de la red trifásica QBO 96. Analizador de los parámetros de la red trifásica QBO 96.](https://www.dacpol.eu/8819-large_default/analizador-de-los-parametros-de-la-red-trifasica-qbo-96.jpg)
![Analizador de los parámetros de la red trifásica QBO 96. Analizador de los parámetros de la red trifásica QBO 96.](https://www.dacpol.eu/8819-large_default/analizador-de-los-parametros-de-la-red-trifasica-qbo-96.jpg)
Debes estar logueado
Las fotos son solo para fines informativos. Ver especificaciones de producto
please use latin characters
Multifunction network analyzer, suitable for three-phase three or four wires systems unbalanced load, even with distorted waveforms. It displays the main electrical measurements of an electrical network, including active and reactive energy counting. The 4 front push-buttons allow immediate display of the relevant measurements concerned without scrolling all display pages. The display measurements sequence is indicated on each-push button and the pictures on the right side sow the sequence of the display values for each key pressure. Thank to the display digits size and to five backlight setting the meter is easy readable even to at large distances and with all light conditions.
Rated data
Display | Backlit LCD |
---|---|
Digits height | 13.5mm |
Max. indication | 4 digits |
Decimal point posistion | Automatic |
Adjustable backlight | 5 levels |
Readings update | <0.5s |
Measuring type | True RMS |
Basic accuracy | ±0.5% |
Rated voltage | 100, 400V |
Rated current | 1, 5A |
Input range | 10-120% UN, 5-120% IN |
Frequency | 45…65Hz |
VT ratio (max. primary) | 1MV |
CT ratio (max. primary) | 15kA |
Continuous overload | 2 x IN, 1.2 x UN |
Short-term overload | 20 x IN, 2 x UN (300msec.) |
Current circuits consumption | <0.5VA |
Voltage circuits consumption | <0.5VA |
Supply voltage | 230V (45…65Hz), 6VA |
Operating temperature | 0…23…50°C |
Storage temperature | -30…70°C |
Housing material | UL 94-V0 |
Protection for housing | IP50 |
Protection for terminals | IP20 |
Galvanic insulation | In./out. |
Installation category | III, 300V, P.D. 2 |
Dimension
Ordering Codes
QUBO | Q96P3L005 | - | CQ2 | - | |
---|---|---|---|---|---|
Communication | None | X | |||
RS485 ModBus | M | ||||
Options | None | - | |||
2 ouputs alarm/pulses | U |
Measured value
Additional technical data
Energy counting | |
---|---|
Number of digits | 10 |
Maximum counting | 2x109 |
Accuracy class | 1 (kWh), 2 (kvarh) |
Bidirectionality | No |
Alarm outputs | |
Activation delay setting | Progr. 0…999s |
Programmability | Variable, value, direction |
Pulse output | |
Programmability | Pulse value |
Pulse duration | Progr. 30…1000ms |
Modbus RTU | |
Interface | RS485 |
Speed (bps) | 9600/19200/38400/57600 |
Communication parameters | Parity and STOP bit |
Addressing range | 1…247 |
Wiring diagrams
Three-phase, three wires system
Three-phase four wires system
¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?
Usted debe estar conectado
Multifunction network analyzer, suitable for three-phase three or four wires systems unbalanced load, even with distorted waveforms. It displays the main electrical measurements of an electrical network, including active and reactive energy counting. The 4 front push-buttons allow immediate display of the relevant measurements concerned without scrolling all display pages. The display measurements sequence is indicated on each-push button and the pictures on the right side sow the sequence of the display values for each key pressure. Thank to the display digits size and to five backlight setting the meter is easy readable even to at large distances and with all light conditions.
Rated data
Display | Backlit LCD |
---|---|
Digits height | 13.5mm |
Max. indication | 4 digits |
Decimal point posistion | Automatic |
Adjustable backlight | 5 levels |
Readings update | <0.5s |
Measuring type | True RMS |
Basic accuracy | ±0.5% |
Rated voltage | 100, 400V |
Rated current | 1, 5A |
Input range | 10-120% UN, 5-120% IN |
Frequency | 45…65Hz |
VT ratio (max. primary) | 1MV |
CT ratio (max. primary) | 15kA |
Continuous overload | 2 x IN, 1.2 x UN |
Short-term overload | 20 x IN, 2 x UN (300msec.) |
Current circuits consumption | <0.5VA |
Voltage circuits consumption | <0.5VA |
Supply voltage | 230V (45…65Hz), 6VA |
Operating temperature | 0…23…50°C |
Storage temperature | -30…70°C |
Housing material | UL 94-V0 |
Protection for housing | IP50 |
Protection for terminals | IP20 |
Galvanic insulation | In./out. |
Installation category | III, 300V, P.D. 2 |
Dimension
Ordering Codes
QUBO | Q96P3L005 | - | CQ2 | - | |
---|---|---|---|---|---|
Communication | None | X | |||
RS485 ModBus | M | ||||
Options | None | - | |||
2 ouputs alarm/pulses | U |
Measured value
Additional technical data
Energy counting | |
---|---|
Number of digits | 10 |
Maximum counting | 2x109 |
Accuracy class | 1 (kWh), 2 (kvarh) |
Bidirectionality | No |
Alarm outputs | |
Activation delay setting | Progr. 0…999s |
Programmability | Variable, value, direction |
Pulse output | |
Programmability | Pulse value |
Pulse duration | Progr. 30…1000ms |
Modbus RTU | |
Interface | RS485 |
Speed (bps) | 9600/19200/38400/57600 |
Communication parameters | Parity and STOP bit |
Addressing range | 1…247 |
Wiring diagrams
Three-phase, three wires system
Three-phase four wires system