Sensor resistivo ACT-31
  • Sensor resistivo ACT-31

Las fotos son solo para fines informativos. Ver especificaciones de producto

please use latin characters

Fabricante: DACPOL

Sensor resistivo ACT-31

Easiest resistance sensor used for very precise temperature measurement of any environment. The only limit is:
- Temperature range, depends on connection cable insulation. (PCV – up to +120°C, teflon – up to +150°C, silicon – up to +180°C, fibre glass – 400°C).
 
SPECIFICATION

SENSOR TECHNICAL PARAMETERS
Measurement resistor Version Characteristic Measurement range Accuracy class Max measurement current Connection type Time constant
T0,5
1xPt100
2xPt100
normal shockproof according to PN-EN-60751 od -50°C
do +250°C
B 8 mA 2 cables ≤ 5s
A 5 mA 3, 4
cables
-50°C+150°C 1/3 B DIN 2 mA

Connection cable
Diameter Średnica Type Skład Operation temperature Cable length LK
2-cables Ø2.9 L2GGD-2xO,22mm2 fibre glass +400°C arbitrary
3, 4 cables  Ø3.1 L4GGD-4xO,22mm2 fibre glass +400°C
2-cables Ø4.2 L2TS-3x0,34mm2 teflon, silicon +180°C
3, 4 cables Ø4.3 L4TTS-4xO,25mm2 teflon, silicon +180°C

 

Marking:
A. Resistor type
A
 
Single
1xPt100
 
Double
2xPt100
B. Accuracy class
B
 
B
B
 
A
A
 
1/3 B DIN
1/3 B DIN
C. Connection and cable type
C
 
2 – cables L2GGD
2p-L2GGD
 
3 – cables L4GGD
3p-L4GGD
 
4 – cables L4GGD
4p-L4GGD
 
2 – cables L2TS
2p-L2TS
 
3 – cables L4TS
3p-L4TS
 
4 – cables L4TS
4p-L4TS
D. Resistor dimensions
D
 
d x L
give in mm
E. Cable length
F
 
LK
give in mm
F. Sensor type
H
 
normal
Z
 
shockproof
W

Caution
There are Non-standard models.
.

 

Envíe una consulta

¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?

Contacta con nosotras
SOLICITA EL PRODUCTO close
Gracias por enviar tu mensaje. Responderemos lo antes posible.
SOLICITA EL PRODUCTO close
Vistazo

Añadir a la lista de deseos

Usted debe estar conectado

Easiest resistance sensor used for very precise temperature measurement of any environment. The only limit is:
- Temperature range, depends on connection cable insulation. (PCV – up to +120°C, teflon – up to +150°C, silicon – up to +180°C, fibre glass – 400°C).
 
SPECIFICATION

SENSOR TECHNICAL PARAMETERS
Measurement resistor Version Characteristic Measurement range Accuracy class Max measurement current Connection type Time constant
T0,5
1xPt100
2xPt100
normal shockproof according to PN-EN-60751 od -50°C
do +250°C
B 8 mA 2 cables ≤ 5s
A 5 mA 3, 4
cables
-50°C+150°C 1/3 B DIN 2 mA

Connection cable
Diameter Średnica Type Skład Operation temperature Cable length LK
2-cables Ø2.9 L2GGD-2xO,22mm2 fibre glass +400°C arbitrary
3, 4 cables  Ø3.1 L4GGD-4xO,22mm2 fibre glass +400°C
2-cables Ø4.2 L2TS-3x0,34mm2 teflon, silicon +180°C
3, 4 cables Ø4.3 L4TTS-4xO,25mm2 teflon, silicon +180°C

 

Marking:
A. Resistor type
A
 
Single
1xPt100
 
Double
2xPt100
B. Accuracy class
B
 
B
B
 
A
A
 
1/3 B DIN
1/3 B DIN
C. Connection and cable type
C
 
2 – cables L2GGD
2p-L2GGD
 
3 – cables L4GGD
3p-L4GGD
 
4 – cables L4GGD
4p-L4GGD
 
2 – cables L2TS
2p-L2TS
 
3 – cables L4TS
3p-L4TS
 
4 – cables L4TS
4p-L4TS
D. Resistor dimensions
D
 
d x L
give in mm
E. Cable length
F
 
LK
give in mm
F. Sensor type
H
 
normal
Z
 
shockproof
W

Caution
There are Non-standard models.
.

 
Comentarios (0)