Sensor resistivo de cabeza ACT-04
  • Sensor resistivo de cabeza ACT-04

Las fotos son solo para fines informativos. Ver especificaciones de producto

please use latin characters

Fabricante: DACPOL

Sensor resistivo de cabeza ACT-04

Straight resistant sensor with stub pipe is used for temperature measurement in machines, pipelines and gas or liquid containers in temperature range -200°C - +600°C. Protection pipe is made from steel 1.4571, 1.7335 and Hastelloy C22, which allows to use thermometer for aggressive media measurement. Version without stub pipe also available.

 
SPECIFICATION:
Model Execution Insert type Length L
U With not changeable insert not changeable arbitrary
PS With changeable insert WP-OP-01/PS
PS/Exi Spark safe with changeable insert
PS/Exe Strengthen casing with changeable insert

SENSOR TECHNICAL PARAMETERS
Measurement resistor Version Characteristic Measurement range Accuracy class Max measurement current Connection type
1xPt100
2xPt100

normal

shockproof

wg PN-EN-60751 from -200°C
up to +600°C
B 8 mA 2 cables
A 5 mA 3, 4
cables
-50°C+150°C 1/3 B DIN 2 mA


Protection pipes
Diameter
d[mm]

Materials according to
WNr/ DIN

Materials according to
ASTM /AISI
Ø4,Ø6,Ø8,Ø9,Ø10, Ø11,Ø12,Ø15 1.4571 316 Ti
Ø10,Ø11,Ø15 1.7335 A182 Grade Fil
Ø13,7 Hastelloy C22 A576 Grade 1020
 
Stub pipe D
M20x1,5
M27x2
G 1/2"
G 3/4"
G 1”
Connection head
Type Max operation temperature Material
B +100°C Al
NA (with silicone washer) +150°C Al
 
Measurement transducer
according to order

 

Marking:

A. Execution
A
 
With not changeable insert
U
 
With changeable insert
PS
 
Spark safe with changeable insert
PS/Exi
 
Strengthen casing with changeable insert
PS/Exe
B. Resistor type
B
 
Single
1xPt100
 
Double
2xPt100
C. Accuracy class
C
 
B
B
 
A
A
 
1/3 B DIN
1/3 B DIN
D. Connection type
D
 
2 - cables
2p
 
3 - cables
3p
 
4 - cables
4p
E. Shield diameter
E
 
Ø4mm
4
 
Ø6mm
6
 
Ø8mm
8
 
Ø9mm
9
 
Ø10mm
10
 
Ø11mm
11
 
Ø12mm
12
 
Ø13.7mm
13.7
 
Ø15mm
15
F. Shield length
F
 
L
give in mm
G. Shield material
G
 
1.4571
1.4571
 
1.7335
1.7335
 
Hastelloy C22
C22
H. Stub pipe
H
 
M20x1.5
M20x1.5
 
M27x2
M27x2
 
G 1/2
G 1/2
 
G 3/4
G 3/4
 
G 1
G 1
I. Head
I
 
NH (at operation temperature up to +100°C)
N1
 
NA (at operation temperature up to +150°C)
N2
 
B
B
K. Operation temperature
K
 
T
give in mm °C
L. Measurement transducer
L
    give type and range in °C
M. Sensor type
M
 
normal 
Z
  shockproof W
 

Envíe una consulta

¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?

Contacta con nosotras
SOLICITA EL PRODUCTO close
Gracias por enviar tu mensaje. Responderemos lo antes posible.
SOLICITA EL PRODUCTO close
Vistazo

Añadir a la lista de deseos

Usted debe estar conectado

Straight resistant sensor with stub pipe is used for temperature measurement in machines, pipelines and gas or liquid containers in temperature range -200°C - +600°C. Protection pipe is made from steel 1.4571, 1.7335 and Hastelloy C22, which allows to use thermometer for aggressive media measurement. Version without stub pipe also available.

 
SPECIFICATION:
Model Execution Insert type Length L
U With not changeable insert not changeable arbitrary
PS With changeable insert WP-OP-01/PS
PS/Exi Spark safe with changeable insert
PS/Exe Strengthen casing with changeable insert

SENSOR TECHNICAL PARAMETERS
Measurement resistor Version Characteristic Measurement range Accuracy class Max measurement current Connection type
1xPt100
2xPt100

normal

shockproof

wg PN-EN-60751 from -200°C
up to +600°C
B 8 mA 2 cables
A 5 mA 3, 4
cables
-50°C+150°C 1/3 B DIN 2 mA


Protection pipes
Diameter
d[mm]

Materials according to
WNr/ DIN

Materials according to
ASTM /AISI
Ø4,Ø6,Ø8,Ø9,Ø10, Ø11,Ø12,Ø15 1.4571 316 Ti
Ø10,Ø11,Ø15 1.7335 A182 Grade Fil
Ø13,7 Hastelloy C22 A576 Grade 1020
 
Stub pipe D
M20x1,5
M27x2
G 1/2"
G 3/4"
G 1”
Connection head
Type Max operation temperature Material
B +100°C Al
NA (with silicone washer) +150°C Al
 
Measurement transducer
according to order

 

Marking:

A. Execution
A
 
With not changeable insert
U
 
With changeable insert
PS
 
Spark safe with changeable insert
PS/Exi
 
Strengthen casing with changeable insert
PS/Exe
B. Resistor type
B
 
Single
1xPt100
 
Double
2xPt100
C. Accuracy class
C
 
B
B
 
A
A
 
1/3 B DIN
1/3 B DIN
D. Connection type
D
 
2 - cables
2p
 
3 - cables
3p
 
4 - cables
4p
E. Shield diameter
E
 
Ø4mm
4
 
Ø6mm
6
 
Ø8mm
8
 
Ø9mm
9
 
Ø10mm
10
 
Ø11mm
11
 
Ø12mm
12
 
Ø13.7mm
13.7
 
Ø15mm
15
F. Shield length
F
 
L
give in mm
G. Shield material
G
 
1.4571
1.4571
 
1.7335
1.7335
 
Hastelloy C22
C22
H. Stub pipe
H
 
M20x1.5
M20x1.5
 
M27x2
M27x2
 
G 1/2
G 1/2
 
G 3/4
G 3/4
 
G 1
G 1
I. Head
I
 
NH (at operation temperature up to +100°C)
N1
 
NA (at operation temperature up to +150°C)
N2
 
B
B
K. Operation temperature
K
 
T
give in mm °C
L. Measurement transducer
L
    give type and range in °C
M. Sensor type
M
 
normal 
Z
  shockproof W
 
Comentarios (0)