Debes estar logueado
-
moreX
-
Componentes
-
-
Category
-
Semiconductores
- Diodos
- Tiristores
-
Módulos con aislamiento eléctrico
- Módulos con aislamiento eléctrico | VISHAY (IR)
- Módulos con aislamiento eléctrico | INFINEON (EUPEC)
- Módulos con aislamiento eléctrico | Semikron
- Módulos con aislamiento eléctrico | POWEREX
- Módulos con aislamiento eléctrico | IXYS
- Módulos con aislamiento eléctrico | POSEICO
- Módulos con aislamiento eléctrico | ABB
- Módulos con aislamiento eléctrico | TECHSEM
- Go to the subcategory
- Rectificadores de puente
-
Transistores
- Transistores | GeneSiC
- Módulos SiC MOSFET | Mitsubishi
- Módulos SiC MOSFET | STARPOWER
- Módulos ABB SiC MOSFET
- Módulos IGBT | MITSUBISHI
- Módulos de transistores | MITSUBISHI
- Módulos MOSFET | MITSUBISHI
- Módulos de transistores | ABB
- Módulos IGBT | POWEREX
- Módulos IGBT | INFINEON (EUPEC)
- Elementos semiconductores de carburo de silicio (SiC)
- Go to the subcategory
- Controladores de puerta
- Bloques de energía
- Go to the subcategory
-
Convertidores de corriente y tensión LEM
-
Transductores de corriente | LEM
- Transductor de corriente con bucle de retroalimentación cerrado (C / L)
- Transductor de corriente con bucle de retroalimentación abierto (O / L)
- Transductor de corriente alimentado por voltaje unipolar
- Transductores en tecnología Eta
- Transductores de corriente de alta precisión serie LF xx10
- Transductores de corriente de la serie LH
- HOYS y HOYL: dedicados para el montaje directamente en un riel conductor
- Convertidores de corriente en la tecnología SMD de las series GO-SME y GO-SMS
- Transductores de corriente AUTOMOCIÓN
- Go to the subcategory
-
Transductores de voltaje | LEM
- Convertidores de voltaje de la serie LV
- Convertidores de voltaje de la serie DVS
- Convertidores de tensión de precisión con doble núcleo magnético serie CV
- Convertidores de tensión de precisión con doble núcleo magnético serie CV
- Convertidores de voltaje de la serie DVM
- Transductor de voltaje - DVC 1000-P
- Transductores de voltaje - Serie DVC 1000
- Go to the subcategory
- Transductores de corriente de precisión | LEM
- Go to the subcategory
-
Transductores de corriente | LEM
-
Componentes pasivos (condensadores, resistencias, fusibles, filtros)
- Resistencias
-
Fusibles
- Fusibles miniatura para circuitos electrónicos, serie ABC y AGC
- Fusibles tubulares de acción rápida
- Eslabones fusibles de retardo de tiempo con características GL / GG y AM
- Eslabones fusibles ultrarrápidos
- Fusibles de acción rápida (estándar británico y estadounidense)
- Fusibles de acción rápida (estándar europeo)
- Fusibles de tracción
- Eslabones fusibles de alto voltaje
- Go to the subcategory
-
Condensadores
- Condensadores de motor
- Condensadores electrolíticos
- Condensadores de película
- Condensadores de potencia
- Condensadores para circuitos de CC
- Condensadores de corrección del factor de potencia
- Condensadores de alto voltaje
- Condensadores de calentamiento por inducción
- Condensadores de almacenamiento de energía y pulsos
- Condensadores de ENLACE CC
- Condensadores para circuitos AC/DC
- Go to the subcategory
- Filtros EMI
- Supercondensadores
-
Protección contra sobretensiones
- Protección contra sobretensiones para aplicaciones coaxiales
- Protección contra sobretensiones para sistemas de videovigilancia
- Protección contra sobretensiones para cableado de potencia
- Pararrayos para LED
- Descargadores de sobretensiones para energía fotovoltaica
- Protección del sistema de pesaje
- Protección contra sobretensiones para Fieldbus
- Go to the subcategory
- Go to the subcategory
-
Relés y contactores
- Teoría de relés y contactores
- Relés semiconductores de CA trifásicos
- Relés semiconductores de CA trifásicos
- Reguladores, controles y accesorios
- Arranques suaves y contactores de inversión
- Relés electromecánicos
- Contactores
- Interruptores giratorios
-
Relés semiconductores de CA monofásicos
- Relés semiconductores CA monofásicos, serie 1 | D2425 | D2450
- Relés semiconductores CA monofásicos, series CWA y CWD
- Relés semiconductores CA monofásicos de las series CMRA y CMRD
- Relés semiconductores de CA monofásicos, serie PS
- Relés semiconductores de CA dobles y cuádruples, serie D24 D, TD24 Q, H12D48 D
- Relés de estado sólido monofásicos, serie gn
- Relés semiconductores de ca monofásicos, serie ckr
- Relés AC monofásicos SERIE ERDA Y ERAA para carril DIN
- Relés AC monofásicos para corriente 150A
- Relés dobles de estado sólido integrados con disipador de calor para carril DIN
- Go to the subcategory
- Relés semiconductores CA monofásicos para PCB
- Relés de interfaz
- Go to the subcategory
- Núcleos y otros componentes inductivos
- Radiadores, varistores, protecciones térmicas
- Aficionados
- Aire Acondicionado, Accesorios para Armarios Eléctricos, Neveras
-
Baterías, cargadores, fuentes de alimentación de búfer e inversores
- Baterías, cargadores - descripción teórica
- Baterías de iones de litio. Baterías personalizadas. Sistema de gestión de batería (BMS)
- Pilas
- Cargadores de baterías y accesorios
- Fuente de alimentación de respaldo de UPS y fuentes de alimentación de búfer
- Convertidores y accesorios para fotovoltaica
- Almacen de energia
- Celdas de combustible
- Baterías de iones de litio
- Go to the subcategory
-
Automaticas
- Futaba Drone Parts
- Finales de carrera, microinterruptores
- Sensores, transductores
- Pirometría
- Contadores, temporizadores, medidores de panel
- Dispositivos de protección industrial
- Señalización luminosa y sonora
- Cámara termográfica
- Pantallas LED
- Botones e interruptores
-
Grabadores
- Grabadora AL3000
- Grabadora KR2000
- Grabadora KR5000
- Medidor HN-CH con función de registro de humedad y temperatura
- Consumibles para registradores
- Grabadora 71VR1
- Grabadora KR 3000
- Grabadores de PC de la serie R1M
- Grabadores de PC de la serie R2M
- Grabador de PC, 12 entradas aisladas - RZMS-U9
- Grabador de PC, USB, 12 entradas aisladas - RZUS
- Go to the subcategory
- Go to the subcategory
-
Cables, alambres Litz, conductos, conexiones flexibles
- alambres
- cables Litz
-
Cables para aplicaciones especiales
- Los cables de extensión y compensación
- Cables para termopares
- Los cables de conexión a PT czyjnków
- Multicore cables temp. -60 ° C a + 1400 ° C
- cables de media tensión SILICOUL
- ignición alambres
- Los cables calefactores
- temp núcleo único. -60 ° C a + 450 ° C
- conductores de trenes
- El calentamiento de los cables en el Ex
- Go to the subcategory
- camisas
-
trenzas
- trenzas planas
- trenzas ronda
- trenza muy flexible - plana
- trenza muy flexible - Ronda
- Copper cilíndrico trenzado
- Copper protector de la trenza y cilíndrica
- cintas de conexión flexibles
- Trenzas cilíndrico galvanizado y acero inoxidable
- Aislamiento de PVC trenzas de cobre - Temperatura 85 ° C
- aluminio trenzado plano
- Kit de conexión - trenzas y tubos
- Go to the subcategory
- Accesorios para la tracción
- Terminales de cable
- barras flexibles aisladas
- carril flexible multicapa
- sistemas de gestión de cables
- Conductos, tuberías
- Go to the subcategory
- View all categories
-
Semiconductores
-
-
- Suppliers
-
Applications
- Accionamientos de CA y CC (inversores)
- Automatización HVAC
- Automatización industrial
- Automatización industrial
- Calentamiento por inducción
- Componentes para atmósferas potencialmente explosivas (EX)
- Dispositivos de protección industrial
- Energy bank
- Equipos para Armarios de Distribución, Control y Telecomunicaciones
- Fuentes de alimentación (UPS) y sistemas rectificadores
- Impresión
- Máquinas de soldar y máquinas de soldar
- Máquinas herramientas CNC
- Máquinas para secar y procesar madera
- Máquinas para termoformado de plásticos
- Medición y regulación de temperatura
- Medición y regulación de temperatura
- Minería, metalurgia y fundación
- Motores y transformadores
- Tracción de tranvía y ferrocarril
-
Instalación
-
-
Montaż urządzeń
- Instalación de armarios
- Diseño y montaje de armarios
- Instalación de sistemas de energía
- Componentes
- Máquinas construidas por encargo
- Trabajo de investigación y desarrollo de I+D.
-
Probadores industriales
- Probadores de semiconductores de potencia
- Comprobadores de aparatos eléctricos
- Comprobadores de varistores y descargadores de sobretensiones
- Probador de fusibles automotriz
- Probador qrr para medir cargas transitorias en tiristores y diodos de potencia
- Comprobador de rotores de interruptores automáticos de la serie FD
- Comprobador de auditoría de dispositivos de corriente residual
- Probador de calibración de relés
- Probador de pruebas visuales de vástagos de resortes de gas
- Interruptor de tiristor de alta corriente
- Probador de rotura de malla
- Go to the subcategory
- View all categories
-
-
-
Inductores
-
-
Modernizacja induktorów
- Reparación de inductores usados
- Modernización de inductores
-
Producción de nuevos inductores.
- Endurecimiento de cigüeñales
- Endurecimiento de los dientes de la sierra de cinta
- Calentamiento de elementos antes de pegar
- Endurecimiento de pistas de rodadura de cojinetes de cubo de rueda de automoción
- Endurecimiento de los componentes de la transmisión motriz
- Endurecimiento de ejes escalonados
- Calentamiento en juntas de contracción
- Endurecimiento de escaneo
- Soldadura blanda
- Calentadores de palanquilla
- Go to the subcategory
- Base de conocimientos
- View all categories
-
-
-
Dispositivos de inducción
-
-
Urządzenia indukcyjne
-
Generadores de calentamiento por inducción
-
Generadores de calentamiento por inducción Ambrell
- Generadores: potencia 500 W, frecuencia 150-400 kHz
- Generadores: Potencia 1,2 - 2,4 kW, frecuencia 150 - 400 kHz
- Generadores: potencia 4.2 - 10 kW, frecuencia 150 - 400 kHz
- Generadores: potencia 10-15 kW, frecuencia 50-150 kHz
- Generadores: potencia 30-45 kW, frecuencia 50-150 kHz
- Generadores: potencia 65-135 kW, frecuencia 50-150 kHz
- Generadores: potencia 180-270 kW, frecuencia 50-150 kHz
- Generadores: potencia 20-35-50 kW, frecuencia 15-45 kHz
- Generadores: cнага 75-150 кВ, фреквенција 15-45 кХз
- Generadores: potencia 200-500 kW, frecuencia 15-45 kHz
- Generadores: potencia 20-50 kW, frecuencia 5-15 kHz
- Go to the subcategory
- Generadores de calentamiento por inducción Denki Kogyo
-
Generadores de calentamiento por inducción JKZ
- Generadores de la serie CX, frecuencia: 50-120kHz, potencia: 5-25kW
- Generadores de la serie SWS, frecuencia: 15-30kHz, potencia: 25-260kW
- Generadores (hornos) para conformar y forjar serie MFS, frecuencia: 0.5-10kHz, potencia: 80-500kW
- Hornos de fusión MFS, frecuencia: 0,5-10 kHz, potencia: 70-200 kW
- Generadores de la serie UHT, frecuencia: 200-400kHz, potencia: 10-160kW
- Go to the subcategory
- Generadores de lámparas para calentamiento por inducción
- Generadores de calentamiento por inducción Himmelwerk
- Go to the subcategory
-
Generadores de calentamiento por inducción Ambrell
- Reparaciones y modernización
- Periféricos
-
Aplicaciones
- Aplicaciones médicas
- Aplicaciones para la industria automotriz
- Soldadura blanda
- Soldadura
- Soldadura fuerte de aluminio
- Soldadura de herramientas magnéticas de acero inoxidable
- Soldadura de precisión
- Soldadura fuerte en atmósfera protectora
- Soldadura de tapas de disipadores de calor de latón y acero
- Soldadura de carburos sinterizados
- Soldar la punta de cobre y el cable
- Go to the subcategory
- Base de conocimientos
- View all categories
-
Generadores de calentamiento por inducción
-
-
-
Servicio
-
-
asd
- Servicio de enfriadores de agua y aires acondicionados industriales
- Reparaciones y modernización de máquinas
-
Reparaciones de electrónica de potencia, electrónica y dispositivos de automatización
- Servicio de inversores, servoaccionamientos y reguladores DC
- Servicio de inversores fotovoltaicos
- Servicio de rectificadores de galvanoplastia FLEXKRAFT
- Oferta de reparación de equipos
- Lista de dispositivos reparados
- Reparación de máquinas de laminado de billetes
- Normativa para la reparación de dispositivos.
- Go to the subcategory
- Fuentes de alimentación de alto voltaje para precipitadores electrostáticos
- Impresoras y etiquetadoras industriales
- Certificates / Entitlements
- View all categories
-
-
- Contact
- Zobacz wszystkie kategorie
Las fotos son solo para fines informativos. Ver especificaciones de producto
please use latin characters
Relés de seguridad / SNO 4063K / SNO 4063km / SNO Puerta de seguridad 4063kr
Base devices for single-channel or two-channel emergency stop,safety gate, safety mat/strip and light curtain monitoring
• Stop category 0 according to EN 60204-1
• Applications up to safety category 4 according to EN 954-1
• Safety category of the devices: 4 according to EN 954-1
• Manual or automatic start
• Cross monitoring
• Single-channel and two-channel control
• 3 enabling current paths (NO contact, positively driven);
feedback loop for monitoring external contactors
• Supply voltage reset with SNO 4063KR (without start inhibit)
• Emergency stop, safety gate, safety mat and light curtain applications
• For processing signals from the output signal switching devices (OSSD) of a light
curtain according to DIN EN 61496-1
• For connecting to a safety mat according to DIN EN 1760-1
SNO 4063K
The device is a two-channel switching device for emergency stop applications with self-monitoring on each ON-OFF cycle. It complies with EN 60204-1 and is equipped with positively driven relays.
Basic function
After supply voltage has been applied to terminals A1 / A2 and the safety inputs closed, operating of the reset button closes the enabling current paths (manual start). When the safety inputs are opened/de-energized the enabling current paths will open.
Operating modes / system functions
•Single or two-channel control
With single-channel control both safety channels CH1 and CH2 are connected in parallel; with two-channel control they are switched separately.
•Without cross monitoring
Both safety channels are switched to the positive potential (S12 and S31 to S11).
•With cross monitoring
Safety channel CH1 is switched to the positive potential (S11 to S12), and safety channel CH2 to the negative potential (S21 to S22).
• Manual start
When the safety inputs are closed, a button is used to open reset input S34 (triggering with falling edge) or to close reset input S35 (triggering with rising edge).
•Automatic start
Reset input S35 is connected to S33. The device starts with the rising edge of the signal on safety input S12.
• Start inhibit
After supply voltage has been applied and the safety inputs closed, the enabling paths will not close. Starting is only possible after the reset button has been operated. For start inhibit the reset inputs have to be controlled with the
button, as with manual start mode.
• Restart inhibit
No restart after the safety inputs have been opened and closed. Restarting is only possible after the reset button has been operated. For restart inhibit the reset inputs have to be activated with the button, as in manual start
mode.
• Semiconductor compatible
OSSD (output signal switching devices) signals from a light curtain or other safety sensors with semiconductor outputs can be processed. Test pulses < t TP do not influence the device functions. Test pulses > t TP can lock the device.
• Synchrocheck
With two-channel control both safety channels are monitored against one another with the synchronous time tS . Safety channel CH1 must close before CH2 and bridge S33 / S35 must be connected. If CH2 closes before CH1, the
synchronous time is t S =∞
SNO 4063KM
The function of this device corresponds to that of the SNO 4063K without synchrocheck. The device is suitable for connecting to light curtains for Si category 4 and to short-circuit forming 4-wire safety mats, switching strips or switching edges (without monitoring resistance).
•Safety mats
The device must be operated with two channels and cross monitoring. If there is resistance < 50 Ω
/ channel and a short circuit between the channels (S11 / S12 and S21 / S22) the enabling paths open and the SUPPLY LED flashes.
•Light curtain for Si category 4
The device will be operated with two channels and without cross monitoring, if the light curtain connected to the OSSD detects a shunt fault on its own.
•Input debouncing
Input debouncing prevents fast consecutive switching of the enabling current paths when the safety inputs are opened for less than t ASP
Safety inputs opened for longer than t ASP lead to opening of the enabling current paths after t R . Restarting is blocked for time t SP
For applications with tactile operating modes (rapid ON-OFF cycles, for example at
manual supply) we recommend the use of SNO 4063KM
SNO 4063K/KR/KM/K-A/KR-A/KM-A | AC/DC 24 V |
SNO 4063K/KR/K-A/KR-A | AC 115 – 120 V/AC 230 V |
A1/A2 S12 S31/S22 S34 K1,K2 13/14,23/24,33/34 tM= minimum ON time tA1 = response time tTP = test pulse time, tR = release time tW = recovery time |
|
A1/A2 S12 S31/S22 S34 K1,K2 13/14,23/24,33/34 tM= minimum ON time tA3/A1 = response time tTP = test pulse time, tR = release time tW = recovery time |
|
A1/A2 S12 S31/S22 S34 K1,K2 13/14,23/24,33/34 tSP= disable time, tA2 = response time tTP = test pulse time, tASP = response time of the disable tR = release time tW = recovery time |
The devices are safety switching devices. They must only be used as components of safety equipment on machines for the purpose of protecting persons, material and machines.
• The safety category according to EN 954-1 depends on the external circuitry, the
choice of control devices and their placement on the machine.
• The indicated times must be observed when the device is operated, otherwise the
device could lock. Locking can be released by properly opening the safety inputs.
• SNE expansion devices or external contactors with positively driven contacts can
be used to multiply the enabling current paths.
• The device and the contacts must be protected with max. 6 A utilization
category gG or through circuit breakers with trigger characteristic B or C.
• The devices are equipped with overload protection (for short circuit). After the
cause of the malfunction has been removed, the device is operational again after
approx. 3 s.
• Control output S11 is exclusively for connecting control devices as defined in the
operating instructions and not for connecting external devices such as lamps, relays
or contactors.
• The devices must be installed in a control cabinet with a protection degree of at
least IP 54
SNO 4062K/SNO 4062KM |
SNO 4062K-A/SNO 4062KM-A |
Overview of devices / Part numbers | |||
---|---|---|---|
type | Rated voltage | Terminals | numer Std. Pack |
SNO 4063K |
DC 12 V
|
Terminal block, rising cage termination | R1.188.1110.0 1 |
AC/DC 24 V 50 - 60 Hz
|
Terminal block, rising cage termination | R1.188.0960.0 1 | |
AC 115 - 120 V 50 - 60 Hz
|
Terminal block, rising cage termination | R1.188.0970.0 1 | |
AC 230 V 50 - 60 Hz
|
Terminal block, rising cage termination | R1.188.0980.0 1 | |
SNO 4063K-A |
DC 12 V
|
Pluggable connector, rising cage terminatio | R1.188.1120.0 1 |
AC/DC 24 V 50 - 60 Hz
|
Pluggable connector, rising cage terminatio | R1.188.0990.0 1 | |
AC 115 - 120 V 50 - 60 Hz
|
Pluggable connector, rising cage terminatio | R1.188.1000.0 1 | |
AC 230 V 50 - 60 Hz
|
Pluggable connector, rising cage terminatio | R1.188.1010.0 1 | |
SNO 4063KM |
AC/DC 24 V 50 - 60 Hz
|
Terminal block, rising cage termination | R1.188.1270.0 1 |
SNO 4063KM-A |
AC/DC 24 V 50 - 60 Hz
|
Pluggable connector, rising cage terminatio | R1.188.1280.0 1 |
SNO 4063KR |
DC 12 V
|
Terminal block, rising cage termination | R1.188.1160.0 1 |
AC/DC 24 V 50 - 60 Hz
|
Terminal block, rising cage termination | R1.188.1130.0 1 | |
AC 115 - 120 V 50 - 60 Hz
|
Terminal block, rising cage termination | R1.188.1140.0 1 | |
AC 230 V 50 - 60 Hz
|
Terminal block, rising cage termination | R1.188.1150.0 1 | |
SNO 4063KR-A |
DC 12 V
|
Pluggable connector, rising cage termination | R1.188.1200.0 1 |
AC/DC 24 V 50 - 60 Hz
|
Pluggable connector, rising cage termination | R1.188.1170.0 1 | |
AC 115 - 120 V 50 - 60 Hz
|
Pluggable connector, rising cage termination | R1.188.1180.0 1 | |
AC 230 V 50 - 60 Hz
|
Pluggable connector, rising cage termination | R1.188.1190.0 1 |
Technical data | SNO 4063K/SNO 4063KR | SNO 4063KM | |
---|---|---|---|
Function according to EN 60204-1
|
Emergency stop relay
|
||
Function display
|
3 LEDs green
|
||
Function diagram
|
FD 221-5-1 W, FD 221-5-2 W, FD 221-5-3 W
|
||
Power supply circuit
|
|||
Rated voltage U
|
DC 12 V,AC/DC 24V,
AC 115 -120 V,AC 230 V |
AC/DC 24 V
|
|
Rated consumption DC
|
2,0 W
|
2,1 W
|
|
Rated consumption AC
|
2,4 W/4,4 VA
|
2,5 W/4,6 VA
|
|
Residual ripple
|
2,4 VSS
|
||
Rated frequency
|
50-60 Hz
|
||
Operating voltage range
|
0,85-1,1xUN
|
||
Fuse for control circuit supply
|
short-circuit resistant
|
||
Control circuit
|
|||
Outputs (S11, S21)
|
|||
Rated output voltage (S11 to S21)
|
DC22V
|
||
Open circuit voltage (only AC devices)
|
<40V
|
||
Output current
|
100 mA
|
||
Short circuit protection / current limitation
|
tak/-
|
tak/250 mA
|
|
Inputs (S12 / S33, S31 / S22, S34, S35)
|
|||
Input voltage range (only for DC devices)
|
DC 17,4 V bis DC 26,4 V
|
||
Rated current / peak current (safety inputs S12 / S33, S31 / S22)
|
40mA/100mA
|
||
Rated current / peak current (reset inputs S34, S35)
|
5 mA/50 mA
|
||
Times
|
|||
Permissible test pulse time tTP / test frequency
|
≤ 1000 us≤10s-1
|
||
Response time tA1 (reset input S34)
|
20 ms - 40 ms
|
||
Response time tA2 (reset input S34)
|
200 ms - 600 ms
|
20 ms - 80 ms
|
|
Response time tA3 (only SNO 4063KR)
|
100ms-400ms
|
||
Minimum ON time tM (reset inputs S34, S35)
|
>80ms
|
||
Locking time tSP
|
-
|
70ms-130ms
|
|
Response time of the lock tASP
|
-
|
>7ms
|
|
Recovery time tW
|
≥100 ms
|
||
Release time tR (K1, K2) with emergency stop
|
<25ms
|
||
Synchronous time tS
|
ca. 200 ms
|
||
Output circuit
|
|||
Enabling paths
|
|||
Contact assignment
|
3 NO contacts, positively driven
|
||
Rated switching voltage U
|
AC 230V/DC 300V
|
||
Max. continuous current I per current path
|
6A
|
||
Max. total current of all current paths DC 12 V, AC/ DC 24 VAC
|
12A 8A
|
||
115 -120 V, AC 230 V
|
|||
Application category according to EN 60947-5 -1 360 h-1
|
AC-15: Ue 230 V AC, Ie 4A / DC-13: Ue24 V DC, Ie 4 A
|
||
3600 h-1
|
AC-15: Ue 230 V AC, Ie 3 A / DC-13: Ue 24 V DC, Ie 2,5 A
|
||
Short-circuit protection, max. fuse insert
|
6 A class gG or circuit breaker with trigger characteristic B or C
|
||
Mechanical life
|
10x106 switching cycles
|
||
General data
|
|||
Creepage distances and clearances between the circuits
|
according EN 60664-1
|
||
Rated impulse voltage
|
4kV
|
||
Overvoltage category
|
III
|
||
Degree of pollution of the device: inside / outside
|
2/3
|
||
Rated voltage
|
AC 300 V
|
||
Test voltage Uaff 50 Hz
|
2kV
|
||
Protection degree according to DIN EN 60529
(housing / terminals)
|
IP40/IP20
|
||
Ambient temperature / storage temperature
|
-25-+55°C/-25-+75°C
|
||
Dimension diagram |
K 4-1 (screw terminals / K 4-2 (pluggable terminals
|
||
Wire ranges fine-stranded / solid or fine-stranded with ferrules
|
2 x 0,14 - 0,75 mm2/1 x 0,14-2,5 mm2
1 x 0,25 - 2,5 mm2/2 x 0,25 - 0,5 mm2 |
||
Permissible tightening torque
|
0,5 - 0,6 Nm
AWG 18-16 tylko przewody Cu |
||
Weight
|
0.21 kg (DC device) / 0.25 kg (AC device)
|
Envíe una consulta
¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?
Contacta con nosotras
Usted debe estar conectado
Base devices for single-channel or two-channel emergency stop,safety gate, safety mat/strip and light curtain monitoring
• Stop category 0 according to EN 60204-1
• Applications up to safety category 4 according to EN 954-1
• Safety category of the devices: 4 according to EN 954-1
• Manual or automatic start
• Cross monitoring
• Single-channel and two-channel control
• 3 enabling current paths (NO contact, positively driven);
feedback loop for monitoring external contactors
• Supply voltage reset with SNO 4063KR (without start inhibit)
• Emergency stop, safety gate, safety mat and light curtain applications
• For processing signals from the output signal switching devices (OSSD) of a light
curtain according to DIN EN 61496-1
• For connecting to a safety mat according to DIN EN 1760-1
SNO 4063K
The device is a two-channel switching device for emergency stop applications with self-monitoring on each ON-OFF cycle. It complies with EN 60204-1 and is equipped with positively driven relays.
Basic function
After supply voltage has been applied to terminals A1 / A2 and the safety inputs closed, operating of the reset button closes the enabling current paths (manual start). When the safety inputs are opened/de-energized the enabling current paths will open.
Operating modes / system functions
•Single or two-channel control
With single-channel control both safety channels CH1 and CH2 are connected in parallel; with two-channel control they are switched separately.
•Without cross monitoring
Both safety channels are switched to the positive potential (S12 and S31 to S11).
•With cross monitoring
Safety channel CH1 is switched to the positive potential (S11 to S12), and safety channel CH2 to the negative potential (S21 to S22).
• Manual start
When the safety inputs are closed, a button is used to open reset input S34 (triggering with falling edge) or to close reset input S35 (triggering with rising edge).
•Automatic start
Reset input S35 is connected to S33. The device starts with the rising edge of the signal on safety input S12.
• Start inhibit
After supply voltage has been applied and the safety inputs closed, the enabling paths will not close. Starting is only possible after the reset button has been operated. For start inhibit the reset inputs have to be controlled with the
button, as with manual start mode.
• Restart inhibit
No restart after the safety inputs have been opened and closed. Restarting is only possible after the reset button has been operated. For restart inhibit the reset inputs have to be activated with the button, as in manual start
mode.
• Semiconductor compatible
OSSD (output signal switching devices) signals from a light curtain or other safety sensors with semiconductor outputs can be processed. Test pulses < t TP do not influence the device functions. Test pulses > t TP can lock the device.
• Synchrocheck
With two-channel control both safety channels are monitored against one another with the synchronous time tS . Safety channel CH1 must close before CH2 and bridge S33 / S35 must be connected. If CH2 closes before CH1, the
synchronous time is t S =∞
SNO 4063KM
The function of this device corresponds to that of the SNO 4063K without synchrocheck. The device is suitable for connecting to light curtains for Si category 4 and to short-circuit forming 4-wire safety mats, switching strips or switching edges (without monitoring resistance).
•Safety mats
The device must be operated with two channels and cross monitoring. If there is resistance < 50 Ω
/ channel and a short circuit between the channels (S11 / S12 and S21 / S22) the enabling paths open and the SUPPLY LED flashes.
•Light curtain for Si category 4
The device will be operated with two channels and without cross monitoring, if the light curtain connected to the OSSD detects a shunt fault on its own.
•Input debouncing
Input debouncing prevents fast consecutive switching of the enabling current paths when the safety inputs are opened for less than t ASP
Safety inputs opened for longer than t ASP lead to opening of the enabling current paths after t R . Restarting is blocked for time t SP
For applications with tactile operating modes (rapid ON-OFF cycles, for example at
manual supply) we recommend the use of SNO 4063KM
SNO 4063K/KR/KM/K-A/KR-A/KM-A | AC/DC 24 V |
SNO 4063K/KR/K-A/KR-A | AC 115 – 120 V/AC 230 V |
A1/A2 S12 S31/S22 S34 K1,K2 13/14,23/24,33/34 tM= minimum ON time tA1 = response time tTP = test pulse time, tR = release time tW = recovery time |
|
A1/A2 S12 S31/S22 S34 K1,K2 13/14,23/24,33/34 tM= minimum ON time tA3/A1 = response time tTP = test pulse time, tR = release time tW = recovery time |
|
A1/A2 S12 S31/S22 S34 K1,K2 13/14,23/24,33/34 tSP= disable time, tA2 = response time tTP = test pulse time, tASP = response time of the disable tR = release time tW = recovery time |
The devices are safety switching devices. They must only be used as components of safety equipment on machines for the purpose of protecting persons, material and machines.
• The safety category according to EN 954-1 depends on the external circuitry, the
choice of control devices and their placement on the machine.
• The indicated times must be observed when the device is operated, otherwise the
device could lock. Locking can be released by properly opening the safety inputs.
• SNE expansion devices or external contactors with positively driven contacts can
be used to multiply the enabling current paths.
• The device and the contacts must be protected with max. 6 A utilization
category gG or through circuit breakers with trigger characteristic B or C.
• The devices are equipped with overload protection (for short circuit). After the
cause of the malfunction has been removed, the device is operational again after
approx. 3 s.
• Control output S11 is exclusively for connecting control devices as defined in the
operating instructions and not for connecting external devices such as lamps, relays
or contactors.
• The devices must be installed in a control cabinet with a protection degree of at
least IP 54
SNO 4062K/SNO 4062KM |
SNO 4062K-A/SNO 4062KM-A |
Overview of devices / Part numbers | |||
---|---|---|---|
type | Rated voltage | Terminals | numer Std. Pack |
SNO 4063K |
DC 12 V
|
Terminal block, rising cage termination | R1.188.1110.0 1 |
AC/DC 24 V 50 - 60 Hz
|
Terminal block, rising cage termination | R1.188.0960.0 1 | |
AC 115 - 120 V 50 - 60 Hz
|
Terminal block, rising cage termination | R1.188.0970.0 1 | |
AC 230 V 50 - 60 Hz
|
Terminal block, rising cage termination | R1.188.0980.0 1 | |
SNO 4063K-A |
DC 12 V
|
Pluggable connector, rising cage terminatio | R1.188.1120.0 1 |
AC/DC 24 V 50 - 60 Hz
|
Pluggable connector, rising cage terminatio | R1.188.0990.0 1 | |
AC 115 - 120 V 50 - 60 Hz
|
Pluggable connector, rising cage terminatio | R1.188.1000.0 1 | |
AC 230 V 50 - 60 Hz
|
Pluggable connector, rising cage terminatio | R1.188.1010.0 1 | |
SNO 4063KM |
AC/DC 24 V 50 - 60 Hz
|
Terminal block, rising cage termination | R1.188.1270.0 1 |
SNO 4063KM-A |
AC/DC 24 V 50 - 60 Hz
|
Pluggable connector, rising cage terminatio | R1.188.1280.0 1 |
SNO 4063KR |
DC 12 V
|
Terminal block, rising cage termination | R1.188.1160.0 1 |
AC/DC 24 V 50 - 60 Hz
|
Terminal block, rising cage termination | R1.188.1130.0 1 | |
AC 115 - 120 V 50 - 60 Hz
|
Terminal block, rising cage termination | R1.188.1140.0 1 | |
AC 230 V 50 - 60 Hz
|
Terminal block, rising cage termination | R1.188.1150.0 1 | |
SNO 4063KR-A |
DC 12 V
|
Pluggable connector, rising cage termination | R1.188.1200.0 1 |
AC/DC 24 V 50 - 60 Hz
|
Pluggable connector, rising cage termination | R1.188.1170.0 1 | |
AC 115 - 120 V 50 - 60 Hz
|
Pluggable connector, rising cage termination | R1.188.1180.0 1 | |
AC 230 V 50 - 60 Hz
|
Pluggable connector, rising cage termination | R1.188.1190.0 1 |
Technical data | SNO 4063K/SNO 4063KR | SNO 4063KM | |
---|---|---|---|
Function according to EN 60204-1
|
Emergency stop relay
|
||
Function display
|
3 LEDs green
|
||
Function diagram
|
FD 221-5-1 W, FD 221-5-2 W, FD 221-5-3 W
|
||
Power supply circuit
|
|||
Rated voltage U
|
DC 12 V,AC/DC 24V,
AC 115 -120 V,AC 230 V |
AC/DC 24 V
|
|
Rated consumption DC
|
2,0 W
|
2,1 W
|
|
Rated consumption AC
|
2,4 W/4,4 VA
|
2,5 W/4,6 VA
|
|
Residual ripple
|
2,4 VSS
|
||
Rated frequency
|
50-60 Hz
|
||
Operating voltage range
|
0,85-1,1xUN
|
||
Fuse for control circuit supply
|
short-circuit resistant
|
||
Control circuit
|
|||
Outputs (S11, S21)
|
|||
Rated output voltage (S11 to S21)
|
DC22V
|
||
Open circuit voltage (only AC devices)
|
<40V
|
||
Output current
|
100 mA
|
||
Short circuit protection / current limitation
|
tak/-
|
tak/250 mA
|
|
Inputs (S12 / S33, S31 / S22, S34, S35)
|
|||
Input voltage range (only for DC devices)
|
DC 17,4 V bis DC 26,4 V
|
||
Rated current / peak current (safety inputs S12 / S33, S31 / S22)
|
40mA/100mA
|
||
Rated current / peak current (reset inputs S34, S35)
|
5 mA/50 mA
|
||
Times
|
|||
Permissible test pulse time tTP / test frequency
|
≤ 1000 us≤10s-1
|
||
Response time tA1 (reset input S34)
|
20 ms - 40 ms
|
||
Response time tA2 (reset input S34)
|
200 ms - 600 ms
|
20 ms - 80 ms
|
|
Response time tA3 (only SNO 4063KR)
|
100ms-400ms
|
||
Minimum ON time tM (reset inputs S34, S35)
|
>80ms
|
||
Locking time tSP
|
-
|
70ms-130ms
|
|
Response time of the lock tASP
|
-
|
>7ms
|
|
Recovery time tW
|
≥100 ms
|
||
Release time tR (K1, K2) with emergency stop
|
<25ms
|
||
Synchronous time tS
|
ca. 200 ms
|
||
Output circuit
|
|||
Enabling paths
|
|||
Contact assignment
|
3 NO contacts, positively driven
|
||
Rated switching voltage U
|
AC 230V/DC 300V
|
||
Max. continuous current I per current path
|
6A
|
||
Max. total current of all current paths DC 12 V, AC/ DC 24 VAC
|
12A 8A
|
||
115 -120 V, AC 230 V
|
|||
Application category according to EN 60947-5 -1 360 h-1
|
AC-15: Ue 230 V AC, Ie 4A / DC-13: Ue24 V DC, Ie 4 A
|
||
3600 h-1
|
AC-15: Ue 230 V AC, Ie 3 A / DC-13: Ue 24 V DC, Ie 2,5 A
|
||
Short-circuit protection, max. fuse insert
|
6 A class gG or circuit breaker with trigger characteristic B or C
|
||
Mechanical life
|
10x106 switching cycles
|
||
General data
|
|||
Creepage distances and clearances between the circuits
|
according EN 60664-1
|
||
Rated impulse voltage
|
4kV
|
||
Overvoltage category
|
III
|
||
Degree of pollution of the device: inside / outside
|
2/3
|
||
Rated voltage
|
AC 300 V
|
||
Test voltage Uaff 50 Hz
|
2kV
|
||
Protection degree according to DIN EN 60529
(housing / terminals)
|
IP40/IP20
|
||
Ambient temperature / storage temperature
|
-25-+55°C/-25-+75°C
|
||
Dimension diagram |
K 4-1 (screw terminals / K 4-2 (pluggable terminals
|
||
Wire ranges fine-stranded / solid or fine-stranded with ferrules
|
2 x 0,14 - 0,75 mm2/1 x 0,14-2,5 mm2
1 x 0,25 - 2,5 mm2/2 x 0,25 - 0,5 mm2 |
||
Permissible tightening torque
|
0,5 - 0,6 Nm
AWG 18-16 tylko przewody Cu |
||
Weight
|
0.21 kg (DC device) / 0.25 kg (AC device)
|
Artículos relacionados
Su agradecimiento a la reseña no pudo ser enviado
Reportar comentario
Reporte enviado
Su reporte no pudo ser enviado
Escriba su propia reseña
Reseña enviada
Su reseña no pudo ser enviada