![Transformadores actuales para SwitchGear - SAV150 Transformadores actuales para SwitchGear - SAV150](https://www.dacpol.eu/8372-large_default/transformadores-actuales-para-switchgear-sav150.jpg)
![Transformadores actuales para SwitchGear - SAV150 Transformadores actuales para SwitchGear - SAV150](https://www.dacpol.eu/8372-large_default/transformadores-actuales-para-switchgear-sav150.jpg)
Debes estar logueado
Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Las fotos son solo para fines informativos. Ver especificaciones de producto
please use latin characters
The SVA150 is specially designed for application in medium voltage installations as Ring Main Units. This cast measuring
transformer is cost effective and very reliable. Multi-core and multi ratio types are available in measuring and protection classes.
Environmental conditionss | |
This product is designed to be safe under the following conditions: | |
Location | Indoor use |
---|---|
Ambient temperature: | -5°C .. +40°C |
Relative humidity: | 5% .. 85%, non condensing |
Protection degree: | IP20 |
Suitable for: | Cables, bus-bar |
Application conditions | |
Standard: | IEC 60044-1 |
Rated short-time thermal current (lth): | 60 x In/1s |
Continuous thermal current (lth): | 100% |
Rated insulation level: | 0,72/3/-kv |
Rated frequency: | 50/60Hz |
Class of insulation: | E |
Primary current | 30-1000A |
Primary window dimensions: | Ø 60mm |
Secondary terminal: | Screw terminals (max. 2Nm) Wire diameter max. 6mm² solid max 4mm² stranded |
Radio | Class | Burden | Atricle number |
---|---|---|---|
600-250/1/1 | 0.2/10P10 | 5VA | 106530 |
400-150/1/1 | 0.2/5P10 | 5VA | 106531 |
Wiring diagram
¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?
Usted debe estar conectado
The SVA150 is specially designed for application in medium voltage installations as Ring Main Units. This cast measuring
transformer is cost effective and very reliable. Multi-core and multi ratio types are available in measuring and protection classes.
Environmental conditionss | |
This product is designed to be safe under the following conditions: | |
Location | Indoor use |
---|---|
Ambient temperature: | -5°C .. +40°C |
Relative humidity: | 5% .. 85%, non condensing |
Protection degree: | IP20 |
Suitable for: | Cables, bus-bar |
Application conditions | |
Standard: | IEC 60044-1 |
Rated short-time thermal current (lth): | 60 x In/1s |
Continuous thermal current (lth): | 100% |
Rated insulation level: | 0,72/3/-kv |
Rated frequency: | 50/60Hz |
Class of insulation: | E |
Primary current | 30-1000A |
Primary window dimensions: | Ø 60mm |
Secondary terminal: | Screw terminals (max. 2Nm) Wire diameter max. 6mm² solid max 4mm² stranded |
Radio | Class | Burden | Atricle number |
---|---|---|---|
600-250/1/1 | 0.2/10P10 | 5VA | 106530 |
400-150/1/1 | 0.2/5P10 | 5VA | 106531 |
Wiring diagram
Su agradecimiento a la reseña no pudo ser enviado
Reportar comentario
Reporte enviado
Su reporte no pudo ser enviado
Escriba su propia reseña
Reseña enviada
Su reseña no pudo ser enviada