Characteristics • Continuous operating temperatures: -60 °C to +180 °C.• Good resistance to thermal shock and UV. • Rated voltage: 300/300 V. • Test voltage: 3750 V. Standard products • Inner insulating layer: white.• Outer insulating layer: all colours including two-coloured. Approvals - standards • VDE approval: Licence No. 119365.• Halogen-free: IEC 60754-1 / EN 60754-1. • Safety of household and similar electrical appliances: NF EN 60335-1. Applications • Class 2 lighting equipment and convectors or any other household electrical appliance complying with standard NF EN 60335-1.• Cabling for rotating machines (class H). Options • Solid tin-plated copper core (ref. RECSC-VDE) – class 1 as per IEC 60228:> See details of the option below. > Option not available in nickel-plated copper. |
![]() 1 • Flexible tin-plated (ref. ECSC-VDE) or nickel-plated (ref. CNCSC-VDE) copper core - class 5 as per IEC 60228 / DIN VDE 0295. |
Flexible core • class 5 as per IEC 60228 | INSULATED WIRE | |||||
---|---|---|---|---|---|---|
Nominal cross-section (mm² | Nominal stranding | Maximum linear resistance at 20 °C (Ω/km) (tin-plated copper core) | Nominal thickness of insulation (mm) | Nominal diameter (mm) | Approximate linear weight (kg/km) | |
on the inner layer | on the outer layer | |||||
0,5 | 16x0,20 | 40.1 | 0.6 | 0.6 | 3.3 | 14.7 |
0,75 | 24 x 0,20 | 26.7 | 0.6 | 0.6 | 3.6 | 18.6 |
1 | 32 x 0,20 | 20.0 | 0.6 | 0.6 | 3.7 | 21.3 |
1,5 | 30 x 0,25 | 13.7 | 0.7 | 0.7 | 4.4 | 30.4 |
2,5 | 50 x 0,25 | 8.21 | 0.8 | 0.8 | 5.2 | 45.5 |
Flexible core • class 5 as per IEC 60228 | INSULATED WIRE | |||||
---|---|---|---|---|---|---|
Nominal cross-section (mm² | Nominal stranding | Maximum linear resistance at 20 °C (Ω/km) (tin-plated copper core) | Nominal thickness of insulation (mm) | Nominal diameter (mm) | Approximate linear weight (kg/km) | |
on the inner layer | on the outer layer | |||||
0,5 | 1 x 0.80 | 36.7 | 0,6 | 0,6 | 3,2 | 14.2 |
0,75 | 1 x 0.98 | 24.8 | 0,6 | 0,6 | 3.4 | 17.5 |
1 | 1 x 1.13 | 18.2 | 0,6 | 0,6 | 3,6 | 20,9 |
1,5 | 1 x 1.38 | 12.2 | 0,7 | 0,7 | 4,2 | 29.4 |
2,5 | 1 x 1.77 | 7.56 | 0,8 | 0,8 | 5.0 | 44.4 |
¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?
Usted debe estar conectado
Characteristics • Continuous operating temperatures: -60 °C to +180 °C.• Good resistance to thermal shock and UV. • Rated voltage: 300/300 V. • Test voltage: 3750 V. Standard products • Inner insulating layer: white.• Outer insulating layer: all colours including two-coloured. Approvals - standards • VDE approval: Licence No. 119365.• Halogen-free: IEC 60754-1 / EN 60754-1. • Safety of household and similar electrical appliances: NF EN 60335-1. Applications • Class 2 lighting equipment and convectors or any other household electrical appliance complying with standard NF EN 60335-1.• Cabling for rotating machines (class H). Options • Solid tin-plated copper core (ref. RECSC-VDE) – class 1 as per IEC 60228:> See details of the option below. > Option not available in nickel-plated copper. |
![]() 1 • Flexible tin-plated (ref. ECSC-VDE) or nickel-plated (ref. CNCSC-VDE) copper core - class 5 as per IEC 60228 / DIN VDE 0295. |
Flexible core • class 5 as per IEC 60228 | INSULATED WIRE | |||||
---|---|---|---|---|---|---|
Nominal cross-section (mm² | Nominal stranding | Maximum linear resistance at 20 °C (Ω/km) (tin-plated copper core) | Nominal thickness of insulation (mm) | Nominal diameter (mm) | Approximate linear weight (kg/km) | |
on the inner layer | on the outer layer | |||||
0,5 | 16x0,20 | 40.1 | 0.6 | 0.6 | 3.3 | 14.7 |
0,75 | 24 x 0,20 | 26.7 | 0.6 | 0.6 | 3.6 | 18.6 |
1 | 32 x 0,20 | 20.0 | 0.6 | 0.6 | 3.7 | 21.3 |
1,5 | 30 x 0,25 | 13.7 | 0.7 | 0.7 | 4.4 | 30.4 |
2,5 | 50 x 0,25 | 8.21 | 0.8 | 0.8 | 5.2 | 45.5 |
Flexible core • class 5 as per IEC 60228 | INSULATED WIRE | |||||
---|---|---|---|---|---|---|
Nominal cross-section (mm² | Nominal stranding | Maximum linear resistance at 20 °C (Ω/km) (tin-plated copper core) | Nominal thickness of insulation (mm) | Nominal diameter (mm) | Approximate linear weight (kg/km) | |
on the inner layer | on the outer layer | |||||
0,5 | 1 x 0.80 | 36.7 | 0,6 | 0,6 | 3,2 | 14.2 |
0,75 | 1 x 0.98 | 24.8 | 0,6 | 0,6 | 3.4 | 17.5 |
1 | 1 x 1.13 | 18.2 | 0,6 | 0,6 | 3,6 | 20,9 |
1,5 | 1 x 1.38 | 12.2 | 0,7 | 0,7 | 4,2 | 29.4 |
2,5 | 1 x 1.77 | 7.56 | 0,8 | 0,8 | 5.0 | 44.4 |