Transformadores actuales con devanado primario RM60-D
  • Transformadores actuales con devanado primario RM60-D

Las fotos son solo para fines informativos. Ver especificaciones de producto

please use latin characters

Fabricante: ELEQ

Transformadores actuales con devanado primario RM60-D

RM series is a low-voltage current transformers.

Properties:
  • secondary currents 5A or 1A in class 1 and 3;
  • primary current up to 30A, 50/60Hz;
  • mounted to base with special terminals ;
  • black, polycarbonate housing;
  • terminals of primary and secondary circuit protected by cover;
  • KEMA EUR certification. 

Applications:

  • operating with ammeters (analog and digital);
  • operating with current recorders;
  • operating with power meters, power factor meters;
  • operating with relays, transducers and energy meters.

Specifications:

Applicable standards IEC 60044-1
Short circuit current 60 x In/1s
Continuous current 1 x In
Insulation level 0,72/3/-kV
Operating frequency 50/60Hz
Insulation class E
Connecting of secondary circuit Zaciski
Mounting Wnętrzowy
Ambient temperature -5°C do +40°C
Ambient humidity 5% do 85%, bez kondensacji
Protection degree IP20

Models:

Secondary current 5A
Class 1 3 Part
numbery
Primary current
[A]
CT load
[VA]
1 5 7,5

4M2011N

1,5 5 7,5

4M2012N

2,5 5 7,5

4M2013N

4 5 7,5

4M2014N

5 5 7,5

4M2015N

6 5 7,5

4M2016N

10 5 7,5

4M2017N

15 5 7,5

4M2018N

20 5 7,5

4M2019N

25 5 7,5

4M2020N

30 5 7,5

4M2021N

Secondary current 5A
Class 1 3 Part
number
Primary current
[A]
CT load
[VA]
1 5 7,5

4M2000N

1,5 5 7,5

4M2001N

2,5 5 7,5

4M2002N

4 5 7,5

4M2003N

5 5 7,5

4M2004N

6 5 7,5

4M2005N

10 5 7,5

4M2006N

15 5 7,5

4M2007N

20 5 7,5

4M2008N

25 5 7,5

4M2009N

30 5 7,5

4M2010N

Dimensions [mm]

Wound primary current transformers RM60-D

Envíe una consulta

¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?

Contacta con nosotras
SOLICITA EL PRODUCTO close
Gracias por enviar tu mensaje. Responderemos lo antes posible.
SOLICITA EL PRODUCTO close
Vistazo

Añadir a la lista de deseos

Usted debe estar conectado

RM series is a low-voltage current transformers.

Properties:
  • secondary currents 5A or 1A in class 1 and 3;
  • primary current up to 30A, 50/60Hz;
  • mounted to base with special terminals ;
  • black, polycarbonate housing;
  • terminals of primary and secondary circuit protected by cover;
  • KEMA EUR certification. 

Applications:

  • operating with ammeters (analog and digital);
  • operating with current recorders;
  • operating with power meters, power factor meters;
  • operating with relays, transducers and energy meters.

Specifications:

Applicable standards IEC 60044-1
Short circuit current 60 x In/1s
Continuous current 1 x In
Insulation level 0,72/3/-kV
Operating frequency 50/60Hz
Insulation class E
Connecting of secondary circuit Zaciski
Mounting Wnętrzowy
Ambient temperature -5°C do +40°C
Ambient humidity 5% do 85%, bez kondensacji
Protection degree IP20

Models:

Secondary current 5A
Class 1 3 Part
numbery
Primary current
[A]
CT load
[VA]
1 5 7,5

4M2011N

1,5 5 7,5

4M2012N

2,5 5 7,5

4M2013N

4 5 7,5

4M2014N

5 5 7,5

4M2015N

6 5 7,5

4M2016N

10 5 7,5

4M2017N

15 5 7,5

4M2018N

20 5 7,5

4M2019N

25 5 7,5

4M2020N

30 5 7,5

4M2021N

Secondary current 5A
Class 1 3 Part
number
Primary current
[A]
CT load
[VA]
1 5 7,5

4M2000N

1,5 5 7,5

4M2001N

2,5 5 7,5

4M2002N

4 5 7,5

4M2003N

5 5 7,5

4M2004N

6 5 7,5

4M2005N

10 5 7,5

4M2006N

15 5 7,5

4M2007N

20 5 7,5

4M2008N

25 5 7,5

4M2009N

30 5 7,5

4M2010N

Dimensions [mm]

Wound primary current transformers RM60-D

Comentarios (0)