Multifunction network analyzer for DC systems. The voltage inputs is directly wired to the line, while the input proportional to the current is derived from shunt. By means of a simple programming procedure is possible to set the value of the primary current.
Rated data
Display | Backlit LCD |
---|---|
Digits height | 13.5mm |
Max. indication | 4 digits |
Decimal point position | Automatic |
Adjustable backlight | 5 levels |
Readings update | <0.5s |
Basic accuracy | ±0.2% |
Nominal input current | Shunt 60mV |
Shunt ratio (max primary) | 15kA |
Input range | 10-120% UN, 5-120% IN |
Continuous overload | 2 x IN, 1.2 x UN |
Short-term overload | 20 x IN, 2 x UN (300msec.) |
Current circutis consumption | <0.5VA |
Voltage circutis consumption | <0.5VA |
Operating temperature | 0…23…50°C |
Storage temperature | -30…70°C |
Housing material | UL 94-V0 |
Protection for housing | IP50 |
Protection for terminasl | IP20 |
Galvanic insulation | In./out. |
Installation category | III, 300V, P.D. 2 |
Dimensions
Code
QUBO 96 DC | Q96C3LX60 | -- | - | - | - | |
---|---|---|---|---|---|---|
Communication | RS485 Modbus | M | ||||
Modbus TCP + WebServer + internal memory | E | |||||
Modbus TCP + WebServer + Gateway | G | |||||
IEC61850 | I | |||||
Profibus DP V0 | P | |||||
Johnson Controls N2 open | J | |||||
Input voltage | 12V | 12 | ||||
24V | 24 | |||||
48V | 48 | |||||
60V | 60 | |||||
110V | C1 | |||||
220V | D2 | |||||
400V | 4C | |||||
600V | 6C | |||||
Aux. power supply | 220-240V AC | 2 | ||||
20-60V AC/DC | L | |||||
80-260V AC/DC | H | |||||
Option | None | - | ||||
2 outputs alarm/pulses | U |
Measured value
Additional technical data
Energy counting | |
---|---|
Number of digits | 10 |
Maximum counting | 2x109 |
Accuracy class | 1 (kWh), 2 (kvarh) |
Bidirectionality | Tak |
Alarm outputs (photo-mos 50V, 100mA) | |
Activation delay setting | Nastawne 0…999s |
Programmability | Varibal, value, direction |
Pulse output | |
Programmability | Pulse value |
Pulse duration | Prog. 30…1000ms |
Modbus RTU | |
Interface | RS485 |
Speed (bps) | 9600/19200/38400/57600 |
Communication parametrs | Parity [&] stop prog. |
Addresing range | 1…247 |
ModBus TCP/Webserver | |
Ehernet interface | IEEE 802.3 (u) 10 Base T/100 Base TX |
Wiring | RJ45 |
Speed | 10/100 Mbit/s |
Duplex | Half/full |
IEC61850 | |
Ethernet inteface | IEEE 802.3 (u) 10 Base T/100 Base TX |
Wiring | RJ45 |
Speed | 10/100 Mbit/s |
Duplex | Half/full |
ProfiBus DP 0V | |
Network | NRZ asynchronous |
Baud rate | 9.6kbit/s…12Mbit/s |
Addresing range | 1…99 prog. |
Complies to | EN 50170 |
Johnson Controls N2 OPEN | |
Inteface | RS485 |
Speed (bps) | 9600 |
Parity | None |
Addresing range | 1…247 prog. |
Wiring diagrams
With shunt on positive polarity
With shunt on negative polarity
Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?
Ajouter à la liste de souhaits
Vous devez être connecté
Multifunction network analyzer for DC systems. The voltage inputs is directly wired to the line, while the input proportional to the current is derived from shunt. By means of a simple programming procedure is possible to set the value of the primary current.
Rated data
Display | Backlit LCD |
---|---|
Digits height | 13.5mm |
Max. indication | 4 digits |
Decimal point position | Automatic |
Adjustable backlight | 5 levels |
Readings update | <0.5s |
Basic accuracy | ±0.2% |
Nominal input current | Shunt 60mV |
Shunt ratio (max primary) | 15kA |
Input range | 10-120% UN, 5-120% IN |
Continuous overload | 2 x IN, 1.2 x UN |
Short-term overload | 20 x IN, 2 x UN (300msec.) |
Current circutis consumption | <0.5VA |
Voltage circutis consumption | <0.5VA |
Operating temperature | 0…23…50°C |
Storage temperature | -30…70°C |
Housing material | UL 94-V0 |
Protection for housing | IP50 |
Protection for terminasl | IP20 |
Galvanic insulation | In./out. |
Installation category | III, 300V, P.D. 2 |
Dimensions
Code
QUBO 96 DC | Q96C3LX60 | -- | - | - | - | |
---|---|---|---|---|---|---|
Communication | RS485 Modbus | M | ||||
Modbus TCP + WebServer + internal memory | E | |||||
Modbus TCP + WebServer + Gateway | G | |||||
IEC61850 | I | |||||
Profibus DP V0 | P | |||||
Johnson Controls N2 open | J | |||||
Input voltage | 12V | 12 | ||||
24V | 24 | |||||
48V | 48 | |||||
60V | 60 | |||||
110V | C1 | |||||
220V | D2 | |||||
400V | 4C | |||||
600V | 6C | |||||
Aux. power supply | 220-240V AC | 2 | ||||
20-60V AC/DC | L | |||||
80-260V AC/DC | H | |||||
Option | None | - | ||||
2 outputs alarm/pulses | U |
Measured value
Additional technical data
Energy counting | |
---|---|
Number of digits | 10 |
Maximum counting | 2x109 |
Accuracy class | 1 (kWh), 2 (kvarh) |
Bidirectionality | Tak |
Alarm outputs (photo-mos 50V, 100mA) | |
Activation delay setting | Nastawne 0…999s |
Programmability | Varibal, value, direction |
Pulse output | |
Programmability | Pulse value |
Pulse duration | Prog. 30…1000ms |
Modbus RTU | |
Interface | RS485 |
Speed (bps) | 9600/19200/38400/57600 |
Communication parametrs | Parity [&] stop prog. |
Addresing range | 1…247 |
ModBus TCP/Webserver | |
Ehernet interface | IEEE 802.3 (u) 10 Base T/100 Base TX |
Wiring | RJ45 |
Speed | 10/100 Mbit/s |
Duplex | Half/full |
IEC61850 | |
Ethernet inteface | IEEE 802.3 (u) 10 Base T/100 Base TX |
Wiring | RJ45 |
Speed | 10/100 Mbit/s |
Duplex | Half/full |
ProfiBus DP 0V | |
Network | NRZ asynchronous |
Baud rate | 9.6kbit/s…12Mbit/s |
Addresing range | 1…99 prog. |
Complies to | EN 50170 |
Johnson Controls N2 OPEN | |
Inteface | RS485 |
Speed (bps) | 9600 |
Parity | None |
Addresing range | 1…247 prog. |
Wiring diagrams