Vous devez être connecté
Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Les photos sont à titre informatif uniquement. Voir les spécifications du produit
please use latin characters
Display | backlit LCD |
---|---|
Max. indication | digits (9999) |
Decimal point position | automatic |
Adjustable backlight | 5 levels |
Readings update | < 0,5 sec. |
Measuring type | TRMS |
Basic accuracy | ±0,5% |
Nominal input voltage Un | 100-400V (Q52P3H); 400V (Q52D3H) |
Nominal input current In | 1-5A; 63A; 125A |
Input range(1) | 10-120% Un, 5-120% In |
Operating frequency | 45...65Hz |
CT ratio (max. primary) | 15000A |
VT radio (max. primary) | 1MV |
Continuous overload | 2 x In; 1.2 x Un |
Short-term overload | 20 x In; 2 x Un (300 msec.) |
Current circuits consumption | < 0.5VA |
Voltage circuits consumption | < 0.5VA |
Power supply | 230V (45...65Hz) ±10% |
Power consumption | 6VA |
Operating temperature | 0...+23...+50°C |
Storage temperature | -30...+70°C |
Self estinguishing | |
Thermoplastic material | UL 94-V0 |
Protection for housing | IP50 |
Protection for terminals | IP20 |
Galvanic insulation | alim./ ingressi aux. supply/inputs |
Test voltage | 2kV, 50Hz, 60sec. |
Compact Multifunction meter suitable for three-phase three or four wires unbalanced load systems. The NANOH H version performs additional “advanced” measurements which allow a very efficent monitoring and supply further information about the system operating conditions. Two versions with direct current input 63 and 125A supplied with triple miniature CTs have been introduced, alongside the version with the CT input, to reduce cost and wiring time. Thanks to its small size and compatibility with spacings of modular switches, the miniature CTs can be mounted in a very small spaces conditions, both upstream and downstream of the 'switch as shown in the picture.
![]() |
![]() |
TYPE | Description | CODE |
---|---|---|
NANO5H | Three-phase 3 or 4 wires input from CT 1-5A |
Q52P3H005MCQ... |
NANO63H | Three-phase 3 or 4 wires fitted with triple CT 63A |
Q52D3H063M4C... |
NANO125H | Three-phase 3 or 4 wires fitted with triple CT 125A |
Q52D3H125M4C... |
Comunication protocols |
Standard | Optional |
---|---|---|
ModBus RTU | + | |
Ethernet-ModBus TCP/Webserver | + | |
Johnson Controls N2 OPEN | + | |
Profibus DP v0 | + |
Measured Variables:
Energy counting | kWh e/and kVarh |
---|---|
maximum counting | 2000000000 |
accuracy class | 1 (kWh), 2 (kVArh) |
bidirectionality | si/yes |
alarm outputs | Photo-mos 50V, 100mA |
activation delay setting | programm. 0...999 sec. |
programmability | variable, value, direction |
pulse outputs | programmabile in alternativa agli allarmi |
programmable as alternative to alarms | |
programmability | peso impulso / pulse value |
pulse duration | Progr. 30...1000 msec. |
interface | RS485 isolata/insulated |
speed (bps) | 9600 / 19200 / 38400 |
communication parameters | parita / parity e / and stop programm. |
addressing range | 1.247 programm. |
ModBus TCP / Webserver Johnson Controls N2 OPEN ProfiBus DP V0 |
by means of external external accessory 2 DIN modules size (pag.11 e 12 |
Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?
Ajouter à la liste de souhaits
Vous devez être connecté
Display | backlit LCD |
---|---|
Max. indication | digits (9999) |
Decimal point position | automatic |
Adjustable backlight | 5 levels |
Readings update | < 0,5 sec. |
Measuring type | TRMS |
Basic accuracy | ±0,5% |
Nominal input voltage Un | 100-400V (Q52P3H); 400V (Q52D3H) |
Nominal input current In | 1-5A; 63A; 125A |
Input range(1) | 10-120% Un, 5-120% In |
Operating frequency | 45...65Hz |
CT ratio (max. primary) | 15000A |
VT radio (max. primary) | 1MV |
Continuous overload | 2 x In; 1.2 x Un |
Short-term overload | 20 x In; 2 x Un (300 msec.) |
Current circuits consumption | < 0.5VA |
Voltage circuits consumption | < 0.5VA |
Power supply | 230V (45...65Hz) ±10% |
Power consumption | 6VA |
Operating temperature | 0...+23...+50°C |
Storage temperature | -30...+70°C |
Self estinguishing | |
Thermoplastic material | UL 94-V0 |
Protection for housing | IP50 |
Protection for terminals | IP20 |
Galvanic insulation | alim./ ingressi aux. supply/inputs |
Test voltage | 2kV, 50Hz, 60sec. |
Compact Multifunction meter suitable for three-phase three or four wires unbalanced load systems. The NANOH H version performs additional “advanced” measurements which allow a very efficent monitoring and supply further information about the system operating conditions. Two versions with direct current input 63 and 125A supplied with triple miniature CTs have been introduced, alongside the version with the CT input, to reduce cost and wiring time. Thanks to its small size and compatibility with spacings of modular switches, the miniature CTs can be mounted in a very small spaces conditions, both upstream and downstream of the 'switch as shown in the picture.
![]() |
![]() |
TYPE | Description | CODE |
---|---|---|
NANO5H | Three-phase 3 or 4 wires input from CT 1-5A |
Q52P3H005MCQ... |
NANO63H | Three-phase 3 or 4 wires fitted with triple CT 63A |
Q52D3H063M4C... |
NANO125H | Three-phase 3 or 4 wires fitted with triple CT 125A |
Q52D3H125M4C... |
Comunication protocols |
Standard | Optional |
---|---|---|
ModBus RTU | + | |
Ethernet-ModBus TCP/Webserver | + | |
Johnson Controls N2 OPEN | + | |
Profibus DP v0 | + |
Measured Variables:
Energy counting | kWh e/and kVarh |
---|---|
maximum counting | 2000000000 |
accuracy class | 1 (kWh), 2 (kVArh) |
bidirectionality | si/yes |
alarm outputs | Photo-mos 50V, 100mA |
activation delay setting | programm. 0...999 sec. |
programmability | variable, value, direction |
pulse outputs | programmabile in alternativa agli allarmi |
programmable as alternative to alarms | |
programmability | peso impulso / pulse value |
pulse duration | Progr. 30...1000 msec. |
interface | RS485 isolata/insulated |
speed (bps) | 9600 / 19200 / 38400 |
communication parameters | parita / parity e / and stop programm. |
addressing range | 1.247 programm. |
ModBus TCP / Webserver Johnson Controls N2 OPEN ProfiBus DP V0 |
by means of external external accessory 2 DIN modules size (pag.11 e 12 |
Votre avis ne peut pas être envoyé
Signaler le commentaire
Signalement envoyé
Votre signalement ne peut pas être envoyé
Donnez votre avis
Avis envoyé
Votre avis ne peut être envoyé