Properties: | |
Materia: | Galvanised Steel Conduit with Polyolefin extra low fire hazard coating) |
Colour: | Black |
Fire Performance: | ![]() |
Temperature Performance: | -25OC +90OC |
IP Rating: | |
• | IP54 with M, S, P or F type fittings |
• | IP65 with C, C-S and C90 type fittings |
Compression Strength: | 350kg/100mm |
Pull-off (Tensile) strength : | 120 kg |
Typical Applications;
![]() |
Construction | ![]() |
Rail |
Compliance, Approvals [&] Accreditation;:
EN 61386 Classification Available on request
COMPLIANT TO LUL STANDARD 1-085-A3
London Underground Certificate No. 297
Vibration and Shock tested to EN61373 Cat 2
Nominal Size |
Part No. | Reel Length [m] |
OD [mm] |
Min ID [mm] |
Min inside Bend radius R [mm] |
---|---|---|---|---|---|
12 |
LFHU12 |
25 | 14.2 | 10.0 | 30 |
16 |
LFHU16 |
25, 50 | 17.1 | 12.9 | 40 |
20 |
LFHU20 |
25, 50 | 21.6 | 16.8 | 45 |
25 |
LFHU25 |
25 | 26.0 | 20.9 | 55 |
32 |
LFHU32 |
25 | 34.0 | 27.8 | 60 |
40 |
LFHU40 |
10 | 44.2 | 37.3 | 80 |
50 |
LFHU50 |
10 | 55.0 | 48.0 | 90 |
63 |
LFHU63 |
10 | 64.5 | 57.0 | 115 |
75 |
LFHU75 |
10 | 79.2 | 69.4 | 150 |
Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?
Ajouter à la liste de souhaits
Vous devez être connecté
Properties: | |
Materia: | Galvanised Steel Conduit with Polyolefin extra low fire hazard coating) |
Colour: | Black |
Fire Performance: | ![]() |
Temperature Performance: | -25OC +90OC |
IP Rating: | |
• | IP54 with M, S, P or F type fittings |
• | IP65 with C, C-S and C90 type fittings |
Compression Strength: | 350kg/100mm |
Pull-off (Tensile) strength : | 120 kg |
Typical Applications;
![]() |
Construction | ![]() |
Rail |
Compliance, Approvals [&] Accreditation;:
EN 61386 Classification Available on request
COMPLIANT TO LUL STANDARD 1-085-A3
London Underground Certificate No. 297
Vibration and Shock tested to EN61373 Cat 2
Nominal Size |
Part No. | Reel Length [m] |
OD [mm] |
Min ID [mm] |
Min inside Bend radius R [mm] |
---|---|---|---|---|---|
12 |
LFHU12 |
25 | 14.2 | 10.0 | 30 |
16 |
LFHU16 |
25, 50 | 17.1 | 12.9 | 40 |
20 |
LFHU20 |
25, 50 | 21.6 | 16.8 | 45 |
25 |
LFHU25 |
25 | 26.0 | 20.9 | 55 |
32 |
LFHU32 |
25 | 34.0 | 27.8 | 60 |
40 |
LFHU40 |
10 | 44.2 | 37.3 | 80 |
50 |
LFHU50 |
10 | 55.0 | 48.0 | 90 |
63 |
LFHU63 |
10 | 64.5 | 57.0 | 115 |
75 |
LFHU75 |
10 | 79.2 | 69.4 | 150 |