Ultrasonic Level Transmitter EAX
  • Ultrasonic Level Transmitter EAX

Les photos sont à titre informatif uniquement. Voir les spécifications du produit

please use latin characters

Fabricant: FineTek

Ultrasonic Level Transmitter EAX

During operation, the device emits a wave towards the measured medium. The wave reflects off the surface and returns to the device, where the transmitter calculates the distance. The distance is based on the time gap between transmission and reception of the wave.

D = (334.1 + 0.6t) x T/2

  • D = transmission distance
  • t = temperature
  • T = transmission time

With the 4-20 mA output, the device can be connected to PLC, DSC, and SCADA systems. Additionally, it is equipped with exclusive PULSE echo tracking and AGC (Auto Gain Control) technology to ensure accuracy and precision even in the most challenging conditions.

Main Features:

  • 2-wire 4-20 mA output (fully isolated) with HART
  • Power supply: 7-30V DC
  • Protective housing: IP67
  • Transmitter material: PVDF
  • False echo detection
  • Internal temperature compensation
  • Beam angle: 7°
  • Measurement unaffected by temperature, specific gravity, or viscosity
  • Maximum range up to 12 meters

Applications:

  • Water treatment or wastewater equipment: pumps, open channels, dams, and wells
  • Edible oils, sauces, and beverages
  • Chemicals: paints, coal, water, oil, epoxy resin, lime sludge, and wax
  • Diesel fuel, petrochemical products, alcohols, solvents, etc.

Envoyez une demande

Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?

Nous contacter
DEMANDEZ LE PRODUIT close
Merci d'avoir envoyé votre message. Nous vous répondrons dans les plus brefs délais.
DEMANDEZ LE PRODUIT close
Feuilleter

Ajouter à la liste de souhaits

Vous devez être connecté

During operation, the device emits a wave towards the measured medium. The wave reflects off the surface and returns to the device, where the transmitter calculates the distance. The distance is based on the time gap between transmission and reception of the wave.

D = (334.1 + 0.6t) x T/2

  • D = transmission distance
  • t = temperature
  • T = transmission time

With the 4-20 mA output, the device can be connected to PLC, DSC, and SCADA systems. Additionally, it is equipped with exclusive PULSE echo tracking and AGC (Auto Gain Control) technology to ensure accuracy and precision even in the most challenging conditions.

Main Features:

  • 2-wire 4-20 mA output (fully isolated) with HART
  • Power supply: 7-30V DC
  • Protective housing: IP67
  • Transmitter material: PVDF
  • False echo detection
  • Internal temperature compensation
  • Beam angle: 7°
  • Measurement unaffected by temperature, specific gravity, or viscosity
  • Maximum range up to 12 meters

Applications:

  • Water treatment or wastewater equipment: pumps, open channels, dams, and wells
  • Edible oils, sauces, and beverages
  • Chemicals: paints, coal, water, oil, epoxy resin, lime sludge, and wax
  • Diesel fuel, petrochemical products, alcohols, solvents, etc.
Commentaires (0)