APPLICATION
CA37, CA39 and CA32 pointer frequency meters are moving-coil meters with built-in measuring transducers intended for measuring voltage frequency in AC electrical networks.
These meters can be mounted on panels of any kind of materials.
We deliver together the meters:
- two screw holders to fix the meter on the panel,
- a terminal shroud (on request),
- a service manual.
BASIC REQUIREMENTS, USER`S SAFETY
CA series meters are destined to be installed on panels or switchboards.
They are in conformity with EN 61010-1 standard requirements.
TECHNICAL DATA
Measuring ranges and accuracy classes: table1Measuring ranges | Accuracy class |
---|---|
45... 55 Hz | 0,5 |
45... 65 Hz | 0,5 |
48... 52 Hz | 0,2 |
55... 65 Hz | 0,5 |
58... 62 Hz | 0,2 |
140... 160 Hz | 0,2 |
180... 220 Hz | 0,2 |
360... 440 Hz | 0,5 |
380... 420 Hz | 0,2 |
Input voltages | 60; 100; 110; 230; 400; 415; 440; 500 lub 690 V± 20% |
Rated operating conditions | |
- ambient temperature | 5...23...40°C |
5...35...55°C | |
- relative air humidity | 25...85% |
- working position | acc. order (±5), Table 2 |
Power consumption | ≤ 2 VA |
Protection Grade acc. to EN60529 | |
- front protection grade: | IP50 for CA37, CA39 and CA32 meters |
IP54 for CA32 meters | |
IP65 for C37 and C39 meters (on request) | |
IP65 for C37 and C39 meters (on request) | |
Electromagnetic compatibility: | |
- emission | acc. EN 61000-6-4 standard |
- mmunity | acc. EN 61000-6-2 standard |
Safety requirements | wg PN-EN 61010-1+A1 |
- installation category | III |
- level of polution | 2 |
Maximal working voltage in relation to the earth | 600 V AC |
Weight | |
– CA32 | 520 g |
– CA37 | 300 g |
– CA39 | 350 g |
ACCESSORIES | |
We deliver with the meter: | |
- screw holders for IP 50 or IP 54 option | 2 pcs |
- screw holders for IP 65 option | 4 pcs |
- terminal protection cover | 1 pcs |
- user’s manual | 1 pc |
![]() |
![]() |
|||||||||||
|
Typ | a | b | c | d | e | f | g | k |
---|---|---|---|---|---|---|---|---|
mm | ||||||||
CA37 |
72 | 4 | 68-0,3 | 5 | 45 | 10..20 | 20,5 | 68+0,7 |
CA39 |
96 | 4 | 92+0,3 | 5 | 45 | 10..20 | 32,5 | 92+0,8 |
CA32 |
144 | 4,5 | 137,3-0,5 | 6 | 48 | 10... 20 | 55,5 | 138+10 |
Example of order
Code: CA37-1-4-O-00-8, means:
The version of a frequency meter, CA37 type in a 72 72 mm case, for the frequency range: 45...55 Hz, rated voltage: 230 V, working position: c3 (90°- vertical), standard version, without additional requirements.
![]() |
|
Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?
Ajouter à la liste de souhaits
Vous devez être connecté
APPLICATION
CA37, CA39 and CA32 pointer frequency meters are moving-coil meters with built-in measuring transducers intended for measuring voltage frequency in AC electrical networks.
These meters can be mounted on panels of any kind of materials.
We deliver together the meters:
- two screw holders to fix the meter on the panel,
- a terminal shroud (on request),
- a service manual.
BASIC REQUIREMENTS, USER`S SAFETY
CA series meters are destined to be installed on panels or switchboards.
They are in conformity with EN 61010-1 standard requirements.
TECHNICAL DATA
Measuring ranges and accuracy classes: table1Measuring ranges | Accuracy class |
---|---|
45... 55 Hz | 0,5 |
45... 65 Hz | 0,5 |
48... 52 Hz | 0,2 |
55... 65 Hz | 0,5 |
58... 62 Hz | 0,2 |
140... 160 Hz | 0,2 |
180... 220 Hz | 0,2 |
360... 440 Hz | 0,5 |
380... 420 Hz | 0,2 |
Input voltages | 60; 100; 110; 230; 400; 415; 440; 500 lub 690 V± 20% |
Rated operating conditions | |
- ambient temperature | 5...23...40°C |
5...35...55°C | |
- relative air humidity | 25...85% |
- working position | acc. order (±5), Table 2 |
Power consumption | ≤ 2 VA |
Protection Grade acc. to EN60529 | |
- front protection grade: | IP50 for CA37, CA39 and CA32 meters |
IP54 for CA32 meters | |
IP65 for C37 and C39 meters (on request) | |
IP65 for C37 and C39 meters (on request) | |
Electromagnetic compatibility: | |
- emission | acc. EN 61000-6-4 standard |
- mmunity | acc. EN 61000-6-2 standard |
Safety requirements | wg PN-EN 61010-1+A1 |
- installation category | III |
- level of polution | 2 |
Maximal working voltage in relation to the earth | 600 V AC |
Weight | |
– CA32 | 520 g |
– CA37 | 300 g |
– CA39 | 350 g |
ACCESSORIES | |
We deliver with the meter: | |
- screw holders for IP 50 or IP 54 option | 2 pcs |
- screw holders for IP 65 option | 4 pcs |
- terminal protection cover | 1 pcs |
- user’s manual | 1 pc |
![]() |
![]() |
|||||||||||
|
Typ | a | b | c | d | e | f | g | k |
---|---|---|---|---|---|---|---|---|
mm | ||||||||
CA37 |
72 | 4 | 68-0,3 | 5 | 45 | 10..20 | 20,5 | 68+0,7 |
CA39 |
96 | 4 | 92+0,3 | 5 | 45 | 10..20 | 32,5 | 92+0,8 |
CA32 |
144 | 4,5 | 137,3-0,5 | 6 | 48 | 10... 20 | 55,5 | 138+10 |
Example of order
Code: CA37-1-4-O-00-8, means:
The version of a frequency meter, CA37 type in a 72 72 mm case, for the frequency range: 45...55 Hz, rated voltage: 230 V, working position: c3 (90°- vertical), standard version, without additional requirements.
![]() |
|