Properties:
• One element power thyristor block with both side cooling– RY
• Water cooling
Typical applications:
• rectifiers, converters, supplies.
• DC power regulators
• power contactors
• soft-starts
Option:
• assembled on clamp K-1 – Drawing. 1
• assembled on clamp K-2 special execution.– Drawing. 2
• assembled on clamp K-5 special execution.– Drawing. 3
• Thermal protection
• RC circuit
• fuse
Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.
Operation conditions:
One element power blocks are used in power electronic systems.
• cooling water temperature 50 C - 300 C @ ambient temperature > -100 C
• Atmospheric pressure 860hPa do 1060hPa
Drawing 1
|
Drawing 2
|
![]() |
![]() |
Drawing 3
|
|
![]() |
Scheme |
Module type | Mean current IF(AV) [A] | Blocking voltage U RRM [V] |
Over current I FSM [A] |
Semiconductor size [mm] |
Block weight [kg] |
---|---|---|---|---|---|
M2T75W | 650…960 | 400…2200 | 8000… 12000 | ![]() |
1,4 |
M2T7W | 450…650 | 400…2400 | 7000…10000 | ![]() |
1,6 |
M2T8W | 630…1000 | 400…8500 | 10000…24000 | ![]() |
1,6 |
M2T9W | 1000…2000 | 400…7500 | 20000…42000 | ![]() |
3,2 |
M2T11W | 1000…3200 | 400…7200 | 27000…65000 | ![]() |
9,8 |
Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?
Ajouter à la liste de souhaits
Vous devez être connecté
Properties:
• One element power thyristor block with both side cooling– RY
• Water cooling
Typical applications:
• rectifiers, converters, supplies.
• DC power regulators
• power contactors
• soft-starts
Option:
• assembled on clamp K-1 – Drawing. 1
• assembled on clamp K-2 special execution.– Drawing. 2
• assembled on clamp K-5 special execution.– Drawing. 3
• Thermal protection
• RC circuit
• fuse
Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.
Operation conditions:
One element power blocks are used in power electronic systems.
• cooling water temperature 50 C - 300 C @ ambient temperature > -100 C
• Atmospheric pressure 860hPa do 1060hPa
Drawing 1
|
Drawing 2
|
![]() |
![]() |
Drawing 3
|
|
![]() |
Scheme |
Module type | Mean current IF(AV) [A] | Blocking voltage U RRM [V] |
Over current I FSM [A] |
Semiconductor size [mm] |
Block weight [kg] |
---|---|---|---|---|---|
M2T75W | 650…960 | 400…2200 | 8000… 12000 | ![]() |
1,4 |
M2T7W | 450…650 | 400…2400 | 7000…10000 | ![]() |
1,6 |
M2T8W | 630…1000 | 400…8500 | 10000…24000 | ![]() |
1,6 |
M2T9W | 1000…2000 | 400…7500 | 20000…42000 | ![]() |
3,2 |
M2T11W | 1000…3200 | 400…7200 | 27000…65000 | ![]() |
9,8 |