Module de tryster - m2t..w
  • Module de tryster - m2t..w

Les photos sont à titre informatif uniquement. Voir les spécifications du produit

please use latin characters

Fabricant: DACPOL

Module de tryster - m2t..w

One element power thyristor block with water radiator.

Properties:
• One element power thyristor block with both side cooling– RY
• Water cooling

Typical applications:
• rectifiers, converters, supplies. 
• DC power regulators
• power contactors
• soft-starts

Option:
• assembled on clamp K-1 – Drawing. 1
• assembled on clamp K-2 special execution.– Drawing. 2
• assembled on clamp K-5 special execution.– Drawing. 3
• Thermal protection
• RC circuit
• fuse


Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.
Operation conditions:
One element power blocks are used in power electronic systems.
• cooling water temperature 50 C - 300 C @ ambient temperature > -100 C
• Atmospheric pressure 860hPa do 1060hPa

Drawing 1
Drawing 2
Drawing 3
 

Scheme

 
 

Table 1 Power blocks parameters
 

Module type Mean current IF(AV) [A] Blocking voltage U RRM
    [V]
Over current
I FSM
[A]
Semiconductor size
[mm]
Block weight
[kg]
M2T75W 650…960 400…2200 8000… 12000 1,4
M2T7W 450…650 400…2400 7000…10000 1,6
M2T8W 630…1000 400…8500 10000…24000 1,6
M2T9W 1000…2000 400…7500 20000…42000 3,2
M2T11W 1000…3200 400…7200 27000…65000 9,8

 
Power block scheme M2T...M
 

Envoyez une demande

Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?

Nous contacter
DEMANDEZ LE PRODUIT close
Merci d'avoir envoyé votre message. Nous vous répondrons dans les plus brefs délais.
DEMANDEZ LE PRODUIT close
Feuilleter

Ajouter à la liste de souhaits

Vous devez être connecté

One element power thyristor block with water radiator.

Properties:
• One element power thyristor block with both side cooling– RY
• Water cooling

Typical applications:
• rectifiers, converters, supplies. 
• DC power regulators
• power contactors
• soft-starts

Option:
• assembled on clamp K-1 – Drawing. 1
• assembled on clamp K-2 special execution.– Drawing. 2
• assembled on clamp K-5 special execution.– Drawing. 3
• Thermal protection
• RC circuit
• fuse


Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.
Operation conditions:
One element power blocks are used in power electronic systems.
• cooling water temperature 50 C - 300 C @ ambient temperature > -100 C
• Atmospheric pressure 860hPa do 1060hPa

Drawing 1
Drawing 2
Drawing 3
 

Scheme

 
 

Table 1 Power blocks parameters
 

Module type Mean current IF(AV) [A] Blocking voltage U RRM
    [V]
Over current
I FSM
[A]
Semiconductor size
[mm]
Block weight
[kg]
M2T75W 650…960 400…2200 8000… 12000 1,4
M2T7W 450…650 400…2400 7000…10000 1,6
M2T8W 630…1000 400…8500 10000…24000 1,6
M2T9W 1000…2000 400…7500 20000…42000 3,2
M2T11W 1000…3200 400…7200 27000…65000 9,8

 
Power block scheme M2T...M
 