DIFIOD POWER Module..P
  • DIFIOD POWER Module..P

Les photos sont à titre informatif uniquement. Voir les spécifications du produit

please use latin characters

Fabricant: DACPOL

DIFIOD POWER Module..P

Two element power diode block with radiator RY.
Properties:
• Two element power diode block with both side cooling– RY
• Natural cooling

Typical applications:
• rectifiers,
• power supplies

Options:
• Standard – Diagram. 1
• With current busses
• With blacken radiator
• Thermal protection
• RC circuit
• fuse
• forced cooling
Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.
Scheme


Operation conditions:
One element power blocks are used in power electronic systems.
• Ambient air temperature-100 C do +400 C;
• Atmospheric pressure  860hPa - 1060hPa
• Humidity less then 80% @ temperature400 C
• Cooling air without aggressive factors.

 

Table 1 Power blocks parameters
 

Module type Mean current IF(AV) [A] Blocking voltage  U RRM
    [V]
Overcurrent
I FSM
[A]
Semiconductor size
[mm]
Block Weight
[kg]
MOC7P 450…650 400…2400 7000…10000 6,9
MOC8P 630…1000 400…8500 10000…24000 6,9
MOC9P 1000…2000 400…7500 20000…42000 16,4
MOC11P 1000…3200 400…6000 27000…65000 18,30

 
Power block scheme MOC...P
 

Envoyez une demande

Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?

Nous contacter
DEMANDEZ LE PRODUIT close
Merci d'avoir envoyé votre message. Nous vous répondrons dans les plus brefs délais.
DEMANDEZ LE PRODUIT close
Feuilleter

Ajouter à la liste de souhaits

Vous devez être connecté

Two element power diode block with radiator RY.
Properties:
• Two element power diode block with both side cooling– RY
• Natural cooling

Typical applications:
• rectifiers,
• power supplies

Options:
• Standard – Diagram. 1
• With current busses
• With blacken radiator
• Thermal protection
• RC circuit
• fuse
• forced cooling
Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.
Scheme


Operation conditions:
One element power blocks are used in power electronic systems.
• Ambient air temperature-100 C do +400 C;
• Atmospheric pressure  860hPa - 1060hPa
• Humidity less then 80% @ temperature400 C
• Cooling air without aggressive factors.

 

Table 1 Power blocks parameters
 

Module type Mean current IF(AV) [A] Blocking voltage  U RRM
    [V]
Overcurrent
I FSM
[A]
Semiconductor size
[mm]
Block Weight
[kg]
MOC7P 450…650 400…2400 7000…10000 6,9
MOC8P 630…1000 400…8500 10000…24000 6,9
MOC9P 1000…2000 400…7500 20000…42000 16,4
MOC11P 1000…3200 400…6000 27000…65000 18,30

 
Power block scheme MOC...P
 