

Vous devez être connecté
Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Les photos sont à titre informatif uniquement. Voir les spécifications du produit
please use latin characters
Properties:
• Double thyristor module with water radiator
• water cooling
Typical applications:
• rectifiers, converters, supplies.
• DC power regulators
• power contactors
• soft-starts
Options:
• Standard – Diagram. 1
• Execution with current busses
• With blacken radiator
• Thermal protection
• RC circuit
• fuse
• forced cooling
Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.
Drawing 1
|
Scheme |
![]() |
![]() |
Operation conditions:
Two element power blocks are used in power electronic systems.
• cooling water temperature 50 C - 300 C with ambient air temperature >-100 C
• Atmospheric pressure 860hPa do 1060hPa
Module type | Mean current IF(AV) [A] | Blocking voltage U RRM [V] |
Overcurrent I FSM [A] |
Semiconductor size [mm] |
Block Weight [kg] |
---|---|---|---|---|---|
M2C7W | 450…650 | 400…2400 | 7000…10000 | ![]() |
3,2 |
M2C8W | 630…1000 | 400…8500 | 10000…24000 | ![]() |
3,6 |
M2C9W | 1000…2000 | 400…7500 | 20000…42000 | ![]() |
6,9 |
M2C11W | 1000…3200 | 400…6000 | 27000…65000 | ![]() |
19,0 |
Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?
Ajouter à la liste de souhaits
Vous devez être connecté
Properties:
• Double thyristor module with water radiator
• water cooling
Typical applications:
• rectifiers, converters, supplies.
• DC power regulators
• power contactors
• soft-starts
Options:
• Standard – Diagram. 1
• Execution with current busses
• With blacken radiator
• Thermal protection
• RC circuit
• fuse
• forced cooling
Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.
Drawing 1
|
Scheme |
![]() |
![]() |
Operation conditions:
Two element power blocks are used in power electronic systems.
• cooling water temperature 50 C - 300 C with ambient air temperature >-100 C
• Atmospheric pressure 860hPa do 1060hPa
Module type | Mean current IF(AV) [A] | Blocking voltage U RRM [V] |
Overcurrent I FSM [A] |
Semiconductor size [mm] |
Block Weight [kg] |
---|---|---|---|---|---|
M2C7W | 450…650 | 400…2400 | 7000…10000 | ![]() |
3,2 |
M2C8W | 630…1000 | 400…8500 | 10000…24000 | ![]() |
3,6 |
M2C9W | 1000…2000 | 400…7500 | 20000…42000 | ![]() |
6,9 |
M2C11W | 1000…3200 | 400…6000 | 27000…65000 | ![]() |
19,0 |
Votre avis ne peut pas être envoyé
Signaler le commentaire
Signalement envoyé
Votre signalement ne peut pas être envoyé
Donnez votre avis
Avis envoyé
Votre avis ne peut être envoyé