Cable data section 1,5 mm2
capacity 150 nF/km
resistance 28 Ω/km
temperature +25 °C
Circuit Alternating current (AC) cable not laid out in parallel,max. length lr:1 km
Tap line max. length of tap line l s and max. line capacity C L depending on supply voltage U
UB 115 230 V
CL 37,5 nF 7,5 nF
lS 250m 50 m
Overview of devices / Part numbers | ||||
---|---|---|---|---|
type | Nominal voltage | Terminals | numer sztk/opak. | |
SNO 4003K | AC/DC 24 V | 50 - 60 Hz | Terminal block, rising cage termination | R1.188.0400.1 1 |
AC 115 - 120 V | 50 - 60 Hz | Terminal block, rising cage termination | R1.188.0880.1 1 | |
AC 230 V | 50 - 60 Hz | Terminal block, rising cage termination | R1.188.0890.1 1 | |
SNO 4003K-A | AC/DC 24 V | 50 - 60 Hz | Terminal block, rising cage termination | R1.188.0500.1 1 |
AC 115 - 120 V | 50 - 60 Hz | Terminal block, rising cage termination | R1.188.0900.1 1 | |
AC 230 V | 50 - 60 Hz | Terminal block, rising cage termination | R1.188.0910.1 1 |
Technical data | SNO 4003K | ||
---|---|---|---|
Function
according to EN 60204-1
|
Emergency stop relay
|
||
Function display
|
2 LEDs green
|
||
Function diagram
|
FD 221-3-1 W, FD 221-3-2 W
|
||
Power supply circuit
|
|||
Devices with rated voltage AC / DC 24 V
|
min | typ | max |
Operating voltage range
|
AC/DC 20,4 V | AC/DC 24 V | AC/DC 26,4 V |
Residual ripple
|
2,4 Vss
|
||
Rated consumption DC
|
- | 1,3 W | 1,6 W |
Rated consumption AC
|
- | 1,8 W/3,2 VA | 2,2 W/3,9 VA |
Rated frequency AC
|
50 Hz | 60Hz | |
Input inrush current (A1)
|
- | - | 1,7 A |
Rated short-circuit current
|
- | 1400 mA | - |
Response time / recovery time
|
2 s/3 s | ||
Fuse for control circuit supply
|
resistor PTC
|
||
Electrical isolation supply circuit – control circuit
|
no
|
||
Devices with rated voltage AC 115-120 V / AC 230 V
|
|||
Operating voltage range Un= AC 115-120 V
|
AC 93,5 V | AC 115-120 V | AC 132 V |
Operating voltage range Un= AC 230 V
|
AC 195 V | AC 230 V | AC 253 V |
Rated consumption
|
- | 2,0 W/2,3 VA | 2,4 W/2,8 VA |
Rated frequency AC
|
50 Hz | 60Hz | |
Wire length to the safe transducer
|
(wires installed in parallel; see the notes on the wire lengths)
|
||
Fuse for control circuit supply
|
Short-circuit proof transformer
|
||
Electrical isolation supply circuit – control circuit
|
yes
|
||
Control circuit
|
|||
Conductor resistance in Y1-Y2 or Y1-Y3 (at U
N
dep. on supply voltage)
|
- | - | 70 Ω |
Rated output voltage to the supply of input Y2
|
DC 24 V | - | |
Open circuit voltage
|
- | - | DC 40 V |
Rated current / peak current (inputs Y2, Y3)
|
- | 90 mA/1500 mA | |
Release time tR (K1, K2)
|
- | 60 ms | 80 ms |
Response time tA1 (devices with rated current AC 115-120 V / AC 230 V)
|
- | 180 ms | 300 ms |
Response time tA1 (devices with rated voltage AC / DC 24 V)
|
- | 40 ms | 60 ms |
Response time tA2
|
40 ms | 60 ms | |
Minimum ON time tM1(Y2)
|
tA1 | - | - |
Minimum ON time tM2(Y3)
|
tA2 | - | |
Recovery time tW
|
- | - | 200 ms |
Stand-by time tB
|
300 ms | ||
Output circuit
|
|||
Contact assignment
|
3 enabling current paths with positively driven contacts (NO), 1 signaling current path (NC)
|
||
Rated switching voltage U
UN |
AC/DC 230 V
|
||
Max. continuous current IN per current path, NO / NC
|
8 A/5 A
|
||
Max. total current of all current paths for devices with rated voltage AC / DC 24 V
|
12 A
|
||
Max. total current of all current paths
for devices with rated voltage AC 115-120 V / AC 230 V
|
8A
|
||
Application category according to EN 60947-5-1 360 h-1
3600 h-1 |
AC-15: Ue 230 V, Ie 4 A / DC-13: Ue 24 V, Ie 4 A
AC-15: Ue 230 V, Ie 3 A / DC-13: Ue 24 V, Ie 2,5 A |
||
Short-circuit protection max. fuse
|
6 A class gG or circuit breaker with trigger characteristic B or C
|
||
Short-circuit protection, fuse
|
max 8A
|
||
Mechanical life
|
10x106 switching operations
|
||
General data
|
|||
Creepage distances and clearances between the circuits
|
according to EN 60664-1
depending on device version; see “Electrical isolation, supply circuit”
|
||
Overvoltage category
|
III
|
||
Rated impulse voltage
|
4 kV
|
||
Rated voltage
|
AC 300 V
|
||
Test AC voltage
|
2 kV
|
||
Degree of pollution of the device: inside / outside
|
2/3
|
||
Protection degree according to DIN EN 60529 (housing / terminals)
|
|||
Ambient temperature / storage temperature
|
-25 - +55 °C/-25 - +75 °C
|
||
Dimension diagram
|
K 4-1 (screw terminals / K 4-2 (pluggable terminals)
|
||
Wire ranges fine-stranded / solid or fine-stranded with ferrules
|
2x0,14 - 0,75 mm2/1x0,14 - 2,5 mm2
1x0,25 - 2,5 mm2/2x0,25 - 0,5 mm2 |
||
Permissible torque
|
0,5 - 0,6 Nm
|
||
Weight for devices with rated voltage AC / DC 24 V
|
0,20 kg
|
||
Weight for devices with rated voltage AC 115-120 V / AC 230 V
|
Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?
Ajouter à la liste de souhaits
Vous devez être connecté
Please also note the information provided by your trade association
Cable data section 1,5 mm2
capacity 150 nF/km
resistance 28 Ω/km
temperature +25 °C
Circuit Alternating current (AC) cable not laid out in parallel,max. length lr:1 km
Tap line max. length of tap line l s and max. line capacity C L depending on supply voltage U
UB 115 230 V
CL 37,5 nF 7,5 nF
lS 250m 50 m
Overview of devices / Part numbers | ||||
---|---|---|---|---|
type | Nominal voltage | Terminals | numer sztk/opak. | |
SNO 4003K | AC/DC 24 V | 50 - 60 Hz | Terminal block, rising cage termination | R1.188.0400.1 1 |
AC 115 - 120 V | 50 - 60 Hz | Terminal block, rising cage termination | R1.188.0880.1 1 | |
AC 230 V | 50 - 60 Hz | Terminal block, rising cage termination | R1.188.0890.1 1 | |
SNO 4003K-A | AC/DC 24 V | 50 - 60 Hz | Terminal block, rising cage termination | R1.188.0500.1 1 |
AC 115 - 120 V | 50 - 60 Hz | Terminal block, rising cage termination | R1.188.0900.1 1 | |
AC 230 V | 50 - 60 Hz | Terminal block, rising cage termination | R1.188.0910.1 1 |
Technical data | SNO 4003K | ||
---|---|---|---|
Function
according to EN 60204-1
|
Emergency stop relay
|
||
Function display
|
2 LEDs green
|
||
Function diagram
|
FD 221-3-1 W, FD 221-3-2 W
|
||
Power supply circuit
|
|||
Devices with rated voltage AC / DC 24 V
|
min | typ | max |
Operating voltage range
|
AC/DC 20,4 V | AC/DC 24 V | AC/DC 26,4 V |
Residual ripple
|
2,4 Vss
|
||
Rated consumption DC
|
- | 1,3 W | 1,6 W |
Rated consumption AC
|
- | 1,8 W/3,2 VA | 2,2 W/3,9 VA |
Rated frequency AC
|
50 Hz | 60Hz | |
Input inrush current (A1)
|
- | - | 1,7 A |
Rated short-circuit current
|
- | 1400 mA | - |
Response time / recovery time
|
2 s/3 s | ||
Fuse for control circuit supply
|
resistor PTC
|
||
Electrical isolation supply circuit – control circuit
|
no
|
||
Devices with rated voltage AC 115-120 V / AC 230 V
|
|||
Operating voltage range Un= AC 115-120 V
|
AC 93,5 V | AC 115-120 V | AC 132 V |
Operating voltage range Un= AC 230 V
|
AC 195 V | AC 230 V | AC 253 V |
Rated consumption
|
- | 2,0 W/2,3 VA | 2,4 W/2,8 VA |
Rated frequency AC
|
50 Hz | 60Hz | |
Wire length to the safe transducer
|
(wires installed in parallel; see the notes on the wire lengths)
|
||
Fuse for control circuit supply
|
Short-circuit proof transformer
|
||
Electrical isolation supply circuit – control circuit
|
yes
|
||
Control circuit
|
|||
Conductor resistance in Y1-Y2 or Y1-Y3 (at U
N
dep. on supply voltage)
|
- | - | 70 Ω |
Rated output voltage to the supply of input Y2
|
DC 24 V | - | |
Open circuit voltage
|
- | - | DC 40 V |
Rated current / peak current (inputs Y2, Y3)
|
- | 90 mA/1500 mA | |
Release time tR (K1, K2)
|
- | 60 ms | 80 ms |
Response time tA1 (devices with rated current AC 115-120 V / AC 230 V)
|
- | 180 ms | 300 ms |
Response time tA1 (devices with rated voltage AC / DC 24 V)
|
- | 40 ms | 60 ms |
Response time tA2
|
40 ms | 60 ms | |
Minimum ON time tM1(Y2)
|
tA1 | - | - |
Minimum ON time tM2(Y3)
|
tA2 | - | |
Recovery time tW
|
- | - | 200 ms |
Stand-by time tB
|
300 ms | ||
Output circuit
|
|||
Contact assignment
|
3 enabling current paths with positively driven contacts (NO), 1 signaling current path (NC)
|
||
Rated switching voltage U
UN |
AC/DC 230 V
|
||
Max. continuous current IN per current path, NO / NC
|
8 A/5 A
|
||
Max. total current of all current paths for devices with rated voltage AC / DC 24 V
|
12 A
|
||
Max. total current of all current paths
for devices with rated voltage AC 115-120 V / AC 230 V
|
8A
|
||
Application category according to EN 60947-5-1 360 h-1
3600 h-1 |
AC-15: Ue 230 V, Ie 4 A / DC-13: Ue 24 V, Ie 4 A
AC-15: Ue 230 V, Ie 3 A / DC-13: Ue 24 V, Ie 2,5 A |
||
Short-circuit protection max. fuse
|
6 A class gG or circuit breaker with trigger characteristic B or C
|
||
Short-circuit protection, fuse
|
max 8A
|
||
Mechanical life
|
10x106 switching operations
|
||
General data
|
|||
Creepage distances and clearances between the circuits
|
according to EN 60664-1
depending on device version; see “Electrical isolation, supply circuit”
|
||
Overvoltage category
|
III
|
||
Rated impulse voltage
|
4 kV
|
||
Rated voltage
|
AC 300 V
|
||
Test AC voltage
|
2 kV
|
||
Degree of pollution of the device: inside / outside
|
2/3
|
||
Protection degree according to DIN EN 60529 (housing / terminals)
|
|||
Ambient temperature / storage temperature
|
-25 - +55 °C/-25 - +75 °C
|
||
Dimension diagram
|
K 4-1 (screw terminals / K 4-2 (pluggable terminals)
|
||
Wire ranges fine-stranded / solid or fine-stranded with ferrules
|
2x0,14 - 0,75 mm2/1x0,14 - 2,5 mm2
1x0,25 - 2,5 mm2/2x0,25 - 0,5 mm2 |
||
Permissible torque
|
0,5 - 0,6 Nm
|
||
Weight for devices with rated voltage AC / DC 24 V
|
0,20 kg
|
||
Weight for devices with rated voltage AC 115-120 V / AC 230 V
|