Vous devez être connecté
Category
Les photos sont à titre informatif uniquement. Voir les spécifications du produit
please use latin characters
Current setting range | 25mA...25A (3 ranges) |
---|---|
current accuracy | +0/- 20% od 20% do100% f.s. |
Delay setting range | 0,1...5 sec (2 ranges) |
Delay accuracy | ±10% of the set values |
Operating frequency | 47...63Hz |
Third harmonic filter | Attenuation 88% @ 150Hz |
Operation characteristic | Typ A wg.IEC775 |
Toroid connection test | Continuous |
Trip contact | SPDT, 5A 250Vac |
Alarm contact | N.E. - N.D. selectable |
Operating temperature | 0...+50°C, U.R. / R.H. <90% n.c. |
Storage temperature | -20...+70°C |
Insulation | 2kV 50Hz, 1 min. |
Connections | Screw max..4 |
Thermoplastic material | UL 94V0 |
Protection for housing | IP40 |
Protection for terminals | IP20 |
According to | IEC 60947-2 |
TYPE |
X52DS |
---|
Characteristics to be specified | |||
---|---|---|---|
Aux. supply voltage | Standard | Va.c. (±10%, 45÷65Hz, 3VA) | 115 - 230 V |
On demand with extraprice |
Va.c. (±10%, 45÷65Hz, 3VA) 115 - 230 V | 24V; 48V; 400V | |
Vd.c. (-15...+20%, 3W) | 24V; 48V; 110V; 220V | ||
Va.c./d.c. (5VA/5W) | 20÷60V; 80÷260V |
DESCRIPTION
The X52DS series earth leakage relays are designed to measure the leakage or unbalance currents caused by conductors or appliances insulation losses and to react, in case the set limits are exceeded, switching off the power supply to the defective system. Main features and functions:
Dimension
Connection diagram
Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?
Ajouter à la liste de souhaits
Vous devez être connecté
Current setting range | 25mA...25A (3 ranges) |
---|---|
current accuracy | +0/- 20% od 20% do100% f.s. |
Delay setting range | 0,1...5 sec (2 ranges) |
Delay accuracy | ±10% of the set values |
Operating frequency | 47...63Hz |
Third harmonic filter | Attenuation 88% @ 150Hz |
Operation characteristic | Typ A wg.IEC775 |
Toroid connection test | Continuous |
Trip contact | SPDT, 5A 250Vac |
Alarm contact | N.E. - N.D. selectable |
Operating temperature | 0...+50°C, U.R. / R.H. <90% n.c. |
Storage temperature | -20...+70°C |
Insulation | 2kV 50Hz, 1 min. |
Connections | Screw max..4 |
Thermoplastic material | UL 94V0 |
Protection for housing | IP40 |
Protection for terminals | IP20 |
According to | IEC 60947-2 |
TYPE |
X52DS |
---|
Characteristics to be specified | |||
---|---|---|---|
Aux. supply voltage | Standard | Va.c. (±10%, 45÷65Hz, 3VA) | 115 - 230 V |
On demand with extraprice |
Va.c. (±10%, 45÷65Hz, 3VA) 115 - 230 V | 24V; 48V; 400V | |
Vd.c. (-15...+20%, 3W) | 24V; 48V; 110V; 220V | ||
Va.c./d.c. (5VA/5W) | 20÷60V; 80÷260V |
DESCRIPTION
The X52DS series earth leakage relays are designed to measure the leakage or unbalance currents caused by conductors or appliances insulation losses and to react, in case the set limits are exceeded, switching off the power supply to the defective system. Main features and functions:
Dimension
Connection diagram