Thick wall heat shrink tubes - type RDK, RDM, RDThey are designed for insulation of metal elements, lampposts, masts, pipelines and elements of bridges.
Due to high shrink ratio, they are a great insulation for cable culverts ends e.g. under the streets.
RDK tubes are wholly adhesive-layered and RDM are supplied with mastic stripes at the ends.
Both adhesive layer and mastic stripes are tight insulation and protect against any moist penetration under the heat shrink layer.
The dimensions of RDK and RDM tubes are specially matched to the sizes of lamposts. They protect them effectively against salt, animals’ urine and gases in the air
Tube with adhesive | Tube with mastik | Tube without adhesive and mastic | Dimensions [mm] | Packing [pcs. 1 m] |
||
---|---|---|---|---|---|---|
Typ | Typ | Typ | D | d | s | |
RDK 55 / 15 |
- |
RD 55 / 15 |
55 | 15 | 4,5 | 40 |
RDK 76 / 18 |
RDM 76 / 18 |
RD 76 / 18 |
76 | 18 | 4,0 | 15 |
RDK 95 / 25 |
RDM 95 / 25 |
RD 95 / 25 |
95 | 25 | 4,5 | 15 |
RDK 105 / 32 |
RDM 105 / 32 |
RD 105 / 32 |
105 | 32 | 4,0 | 12 |
RDK 140 / 34 |
RDM 140 / 34 |
RD 140 / 34 |
140 | 34 | 4,5 | 8 |
RDK 155 / 90 |
RDM 155 / 90 |
RD 155 / 90 |
155 | 90 | 2,9 | 1 |
RDK 175 / 90 |
RDM 175 / 90 |
RD 175 / 90 |
175 | 90 | 2,9 | 1 |
RDK 195 / 90 |
RDM 195 / 90 |
RD 195 / 90 |
195 | 90 | 2,5 | 1 |
RDK 225 / 90 |
RDM 225 / 90 |
RD 225 / 90 |
225 | 90 | 2,5 | 1 |
RDK 245 / 125 |
RDM 245 / 125 |
RD 245 / 125 |
245 | 125 | 2,8 | 1 |
RDK 255 / 125 |
RDM 255 / 125 |
RD 255 / 125 |
255 | 125 | 2,8 | 1 |
RDK 275 / 125 |
RDM 275 / 125 |
RD 275 / 125 |
275 | 125 | 2,8 | 1 |
RDK 300 / 125 |
RDM 300 / 125 |
RD 300 / 125 |
300 | 125 | 2,8 | 1 |
RDK 350 / 125 |
RDM 350 / 125 |
RD 350 / 125 |
350 | 125 | 2,8 | 1 |
RDK 390 / 200 |
RDM 390 / 200 |
RD 390 / 200 |
390 | 200 | 3 | 1 |
RDK 400 / 200 |
RDM 400 / 200 |
RD 400 / 200 |
400 | 200 | 3 | 1 |
RDK 440 / 200 |
RDM 440 / 200 |
RD 440 / 200 |
440 | 200 | 3 | 1 |
RDK 460 / 200 |
RDM 460 / 200 |
RD 460 / 200 |
460 | 200 | 3 | 1 |
RDK 500 / 200 |
RDM 500 / 200 |
RD 500 / 200 |
500 | 200 | 3 | 1 |
RDK 530 / 200 |
RDM 530 / 200 |
RD 530 / 200 |
530 | 200 | 3 | 1 |
RDK 560 / 250 |
RDM 560 / 250 |
RD 560 / 250 |
560 | 250 | 3,2 | 1 |
RDK 620 / 250 |
RDM 620 / 250 |
RD 620 / 250 |
620 | 250 | 3,2 | 1 |
RDK 710 / 250 |
RDM 710 / 250 |
RD 710 / 250 |
710 | 250 | 3,2 | 1 |
D - minimum internal diamter before recovery
d - maximuminternal diamter before recovery
s - wall thicknes after entire recovery
Properties | Test method | Tubes RDK/RDM/RD |
---|---|---|
Operating temperature | -15 up to +125°C / -40 up to +125 / -55 up to +125 | |
Length change after shrinking | EN 60684-2 | +5 ÷ -15% |
Tensile strength, min | EN 60684-2 | 12 MPa |
Elongation at rupture, min. | EN 60684-2 | 300% |
Heat ageing (168 h, temperature) | EN 60684-2 | 158°C |
Tensile strength after heat ageing, min. | EN 60684-2 | 10 MPa |
Elongation at rupture after heat ageing, min. | EN 60684-2 | 200% |
Heat shock (4 hours, temperature) | EN 60684-2 | 200°C no dripping, breaking and wall spread |
Contact with Cu after heat ageing (168 hours, temperature): elongation at rupture, min. |
EN 60684-2 | 158°C 100% |
Cu corrosion | EN 60684-2 | doesn't corrodee |
Cold bend; 4 hours | EN 60684-2 | doesn't break in temp. -55°C |
Flammability | EN 60684-2 | firearms |
Water absorptivity, max | ISO 62 | 0,1% |
Dielectric resistance, min. | EN 60684-2; IEC 60243-1 | 16kV/mm |
Volume resistivity, min. | EN 60684-2; IEC 60093 | 1012Ωm |
Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?
Ajouter à la liste de souhaits
Vous devez être connecté
Application:
Thick wall heat shrink tubes - type RDK, RDM, RDThey are designed for insulation of metal elements, lampposts, masts, pipelines and elements of bridges.
Due to high shrink ratio, they are a great insulation for cable culverts ends e.g. under the streets.
RDK tubes are wholly adhesive-layered and RDM are supplied with mastic stripes at the ends.
Both adhesive layer and mastic stripes are tight insulation and protect against any moist penetration under the heat shrink layer.
The dimensions of RDK and RDM tubes are specially matched to the sizes of lamposts. They protect them effectively against salt, animals’ urine and gases in the air
Tube with adhesive | Tube with mastik | Tube without adhesive and mastic | Dimensions [mm] | Packing [pcs. 1 m] |
||
---|---|---|---|---|---|---|
Typ | Typ | Typ | D | d | s | |
RDK 55 / 15 |
- |
RD 55 / 15 |
55 | 15 | 4,5 | 40 |
RDK 76 / 18 |
RDM 76 / 18 |
RD 76 / 18 |
76 | 18 | 4,0 | 15 |
RDK 95 / 25 |
RDM 95 / 25 |
RD 95 / 25 |
95 | 25 | 4,5 | 15 |
RDK 105 / 32 |
RDM 105 / 32 |
RD 105 / 32 |
105 | 32 | 4,0 | 12 |
RDK 140 / 34 |
RDM 140 / 34 |
RD 140 / 34 |
140 | 34 | 4,5 | 8 |
RDK 155 / 90 |
RDM 155 / 90 |
RD 155 / 90 |
155 | 90 | 2,9 | 1 |
RDK 175 / 90 |
RDM 175 / 90 |
RD 175 / 90 |
175 | 90 | 2,9 | 1 |
RDK 195 / 90 |
RDM 195 / 90 |
RD 195 / 90 |
195 | 90 | 2,5 | 1 |
RDK 225 / 90 |
RDM 225 / 90 |
RD 225 / 90 |
225 | 90 | 2,5 | 1 |
RDK 245 / 125 |
RDM 245 / 125 |
RD 245 / 125 |
245 | 125 | 2,8 | 1 |
RDK 255 / 125 |
RDM 255 / 125 |
RD 255 / 125 |
255 | 125 | 2,8 | 1 |
RDK 275 / 125 |
RDM 275 / 125 |
RD 275 / 125 |
275 | 125 | 2,8 | 1 |
RDK 300 / 125 |
RDM 300 / 125 |
RD 300 / 125 |
300 | 125 | 2,8 | 1 |
RDK 350 / 125 |
RDM 350 / 125 |
RD 350 / 125 |
350 | 125 | 2,8 | 1 |
RDK 390 / 200 |
RDM 390 / 200 |
RD 390 / 200 |
390 | 200 | 3 | 1 |
RDK 400 / 200 |
RDM 400 / 200 |
RD 400 / 200 |
400 | 200 | 3 | 1 |
RDK 440 / 200 |
RDM 440 / 200 |
RD 440 / 200 |
440 | 200 | 3 | 1 |
RDK 460 / 200 |
RDM 460 / 200 |
RD 460 / 200 |
460 | 200 | 3 | 1 |
RDK 500 / 200 |
RDM 500 / 200 |
RD 500 / 200 |
500 | 200 | 3 | 1 |
RDK 530 / 200 |
RDM 530 / 200 |
RD 530 / 200 |
530 | 200 | 3 | 1 |
RDK 560 / 250 |
RDM 560 / 250 |
RD 560 / 250 |
560 | 250 | 3,2 | 1 |
RDK 620 / 250 |
RDM 620 / 250 |
RD 620 / 250 |
620 | 250 | 3,2 | 1 |
RDK 710 / 250 |
RDM 710 / 250 |
RD 710 / 250 |
710 | 250 | 3,2 | 1 |
D - minimum internal diamter before recovery
d - maximuminternal diamter before recovery
s - wall thicknes after entire recovery
Properties | Test method | Tubes RDK/RDM/RD |
---|---|---|
Operating temperature | -15 up to +125°C / -40 up to +125 / -55 up to +125 | |
Length change after shrinking | EN 60684-2 | +5 ÷ -15% |
Tensile strength, min | EN 60684-2 | 12 MPa |
Elongation at rupture, min. | EN 60684-2 | 300% |
Heat ageing (168 h, temperature) | EN 60684-2 | 158°C |
Tensile strength after heat ageing, min. | EN 60684-2 | 10 MPa |
Elongation at rupture after heat ageing, min. | EN 60684-2 | 200% |
Heat shock (4 hours, temperature) | EN 60684-2 | 200°C no dripping, breaking and wall spread |
Contact with Cu after heat ageing (168 hours, temperature): elongation at rupture, min. |
EN 60684-2 | 158°C 100% |
Cu corrosion | EN 60684-2 | doesn't corrodee |
Cold bend; 4 hours | EN 60684-2 | doesn't break in temp. -55°C |
Flammability | EN 60684-2 | firearms |
Water absorptivity, max | ISO 62 | 0,1% |
Dielectric resistance, min. | EN 60684-2; IEC 60243-1 | 16kV/mm |
Volume resistivity, min. | EN 60684-2; IEC 60093 | 1012Ωm |