Série Recti-3Ph
  • Série Recti-3Ph

Les photos sont à titre informatif uniquement. Voir les spécifications du produit

please use latin characters

Fabricant: PEM

Série Recti-3Ph

The RCTi is a current transducer for permanent installation. Simple to install and easy to retrofit, the Rogowski (sense) coil is thin, lightweight, flexible and clip-around. The secondary output from the transducer is an instantaneous voltage proportional to the measured primary current providing an accurate, low cost, wide-band measurement of the primary current. The RCTi is typically used with power and harmonic meters and analyzers, current meters, oscilloscopes, data-loggers, data acquisition cards, and in power quality applications.

Features:

  • Easy to retrofit
  • Simple to install in applications where space is limited
  • Non-intrusive - no power drawn from the primary circuit
  • Wide-band up to 1MHz, to measure harmonic components or complex waveforms (e.g. induction heating, VF drives, power measurement
  • The size of the Rogowski coil can be specified independently of the primary current
  • Does not suffer from magnetic saturation
  • Intrinsically safe
  • Equivalent to Class 1 CT or better
  • Low cost monitoring for medium/large currents. 
 
Rated current [Arms] 250, 500, 800, 1000, 1600, 2000, 2500, 3000, 4000, 5000, 8000,
10000, 16000, 20000, 25000, 30000, 40000, 50000
Rated output (Full scale FS)

5,0Vrms (±7,07V peak)

Output limit 150% fs (±10,6V peak)
Supply voltage (Wide input) 12Vdc (-10%) to 24Vdc (+20%)
Max. Input power 1,2W
Operating temperature range -5°C do +65°C (Integrator electronics)
-20°C do +80°C (Coil and cable)
Bandwidth (-3dB) (<2000A) 0,6Hz do 1MHz (300mm) 600kHz (700mm)
(≥2000A) 0,2Hz do 1MHz (300mm) 600kHz (700mm)
Phase shift @50Hz <2000A) 0,9±0,1degrees
(≥2000A) 0,4±0,1 degrees
Accuracy (typ.) ±1.0% of reading (5% to 150% FS, 25°C)
Output load >10,0kΩ
Coil Length 300mm, 500mm lub 700mm (Custom lengths available)
Cable Length (coil to electronics) 1m lub 2,5m (Custom lengths available)

Connections
Catalogue number
Rated current [A]:
250, 500, 800, 1000, 1600, 2000, 2500, 3000, 4000, 5000, 8000, 10000, 16000, 20000, 25000, 30000, 40000, 50000
Cable Length [m]:
1
2,5
.... Custom lengths available
Coil Length [mm]:
300
500
700
.... . Custom lengths available
Options
BC - Isolated BNC-BNC cable split option
Dimensions [mm]

Envoyez une demande

Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?

Nous contacter
DEMANDEZ LE PRODUIT close
Merci d'avoir envoyé votre message. Nous vous répondrons dans les plus brefs délais.
DEMANDEZ LE PRODUIT close
Feuilleter

Ajouter à la liste de souhaits

Vous devez être connecté

The RCTi is a current transducer for permanent installation. Simple to install and easy to retrofit, the Rogowski (sense) coil is thin, lightweight, flexible and clip-around. The secondary output from the transducer is an instantaneous voltage proportional to the measured primary current providing an accurate, low cost, wide-band measurement of the primary current. The RCTi is typically used with power and harmonic meters and analyzers, current meters, oscilloscopes, data-loggers, data acquisition cards, and in power quality applications.

Features:

  • Easy to retrofit
  • Simple to install in applications where space is limited
  • Non-intrusive - no power drawn from the primary circuit
  • Wide-band up to 1MHz, to measure harmonic components or complex waveforms (e.g. induction heating, VF drives, power measurement
  • The size of the Rogowski coil can be specified independently of the primary current
  • Does not suffer from magnetic saturation
  • Intrinsically safe
  • Equivalent to Class 1 CT or better
  • Low cost monitoring for medium/large currents. 
 
Rated current [Arms] 250, 500, 800, 1000, 1600, 2000, 2500, 3000, 4000, 5000, 8000,
10000, 16000, 20000, 25000, 30000, 40000, 50000
Rated output (Full scale FS)

5,0Vrms (±7,07V peak)

Output limit 150% fs (±10,6V peak)
Supply voltage (Wide input) 12Vdc (-10%) to 24Vdc (+20%)
Max. Input power 1,2W
Operating temperature range -5°C do +65°C (Integrator electronics)
-20°C do +80°C (Coil and cable)
Bandwidth (-3dB) (<2000A) 0,6Hz do 1MHz (300mm) 600kHz (700mm)
(≥2000A) 0,2Hz do 1MHz (300mm) 600kHz (700mm)
Phase shift @50Hz <2000A) 0,9±0,1degrees
(≥2000A) 0,4±0,1 degrees
Accuracy (typ.) ±1.0% of reading (5% to 150% FS, 25°C)
Output load >10,0kΩ
Coil Length 300mm, 500mm lub 700mm (Custom lengths available)
Cable Length (coil to electronics) 1m lub 2,5m (Custom lengths available)

Connections
Catalogue number
Rated current [A]:
250, 500, 800, 1000, 1600, 2000, 2500, 3000, 4000, 5000, 8000, 10000, 16000, 20000, 25000, 30000, 40000, 50000
Cable Length [m]:
1
2,5
.... Custom lengths available
Coil Length [mm]:
300
500
700
.... . Custom lengths available
Options
BC - Isolated BNC-BNC cable split option
Dimensions [mm]

Commentaires (0)