Vous devez être connecté
Category
Les photos sont à titre informatif uniquement. Voir les spécifications du produit
please use latin characters
The RCTrms is an AC current transducer for permanent installation. Simple to install and easy to retrofit it combines the benefits of a thin, flexible, clip-around Rogowski (sense) coil with a signal conditioner providing accurate, true rms measurement, of AC current. The RCTrms has an industry standard 4-20mA output making it ideal for process control, status alarming or system monitoring purposes. Typically the RCTrms is used with SCADA systems, PLCs, data loggers and protection equipment.
Features:
Technical data:
Options:
Rated current [Arms] | 100, 250, 500, 800, 1000, 1600, 2000, 2500, 3000, 4000, 5000, 8000,10000,16000, 20000, 25000, 40000, 50000 |
---|---|
Rated output (Full scale FS) |
4 ÷ 20mA |
Output limit | 150% FS (28mA) |
Supply voltage (Wide input) | 12Vdc (-10%) to 24Vdc (+20%) |
Input power | 0.7W (at rated output) |
Operating temperature range | -5°C do +65°C (Integrator electronics) |
-20°C do +80°C (Coil and cable) | |
Bandwidth (-3dB) | 2Hz do 100kHz |
Max. Response time (10 to 90%) | 1000ms |
Accuracy (typ.) | ±1.5% of reading (10% to 150% FS, 25°C) |
Output load | <300Ω |
Coil Length | 300mm, 500mm or 700mm (Custom lengths available) |
Cable Length | 1m or 2,5m (Custom lengths available) |
![]() |
|
![]() |
Current range [A]: 250, 500, 800, 1000, 1600, 2000, 2500, 3000, 4000, 5000, 8000, 10000, 16000, 20000, 25000, 30000, 40000, 50000 |
![]() |
Cable Length [m]: 1 2,5 .... Custom lengths available |
![]() |
Coil Length [mm]: 300 500 700 .... Custom lengths available |
![]() |
Options: BC - option with detachable cable with BNC terminals |
Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?
Ajouter à la liste de souhaits
Vous devez être connecté
The RCTrms is an AC current transducer for permanent installation. Simple to install and easy to retrofit it combines the benefits of a thin, flexible, clip-around Rogowski (sense) coil with a signal conditioner providing accurate, true rms measurement, of AC current. The RCTrms has an industry standard 4-20mA output making it ideal for process control, status alarming or system monitoring purposes. Typically the RCTrms is used with SCADA systems, PLCs, data loggers and protection equipment.
Features:
Technical data:
Options:
Rated current [Arms] | 100, 250, 500, 800, 1000, 1600, 2000, 2500, 3000, 4000, 5000, 8000,10000,16000, 20000, 25000, 40000, 50000 |
---|---|
Rated output (Full scale FS) |
4 ÷ 20mA |
Output limit | 150% FS (28mA) |
Supply voltage (Wide input) | 12Vdc (-10%) to 24Vdc (+20%) |
Input power | 0.7W (at rated output) |
Operating temperature range | -5°C do +65°C (Integrator electronics) |
-20°C do +80°C (Coil and cable) | |
Bandwidth (-3dB) | 2Hz do 100kHz |
Max. Response time (10 to 90%) | 1000ms |
Accuracy (typ.) | ±1.5% of reading (10% to 150% FS, 25°C) |
Output load | <300Ω |
Coil Length | 300mm, 500mm or 700mm (Custom lengths available) |
Cable Length | 1m or 2,5m (Custom lengths available) |
![]() |
|
![]() |
Current range [A]: 250, 500, 800, 1000, 1600, 2000, 2500, 3000, 4000, 5000, 8000, 10000, 16000, 20000, 25000, 30000, 40000, 50000 |
![]() |
Cable Length [m]: 1 2,5 .... Custom lengths available |
![]() |
Coil Length [mm]: 300 500 700 .... Custom lengths available |
![]() |
Options: BC - option with detachable cable with BNC terminals |