• Continuous operating temperatures: -60 °C to +180 °C.
• Good resistance to thermal shock and UV.
• Excellent mechanical strength.
• Rated voltage: 6.6 kV.
• Test voltage: 15 kV.
Standard products
• Standard insulation colour: white.
• Standard reinforcing braid colour: grey.
Approvals - standards
• Lloyd’s Register approval certificates: compliance with the tests described as per standards
IEC 60228, IEC 60092-350/354/360,
IEC 60754-2, IEC 60332-1-1/2,
IEC 60332-3-22 category A and IEC 60331-11/21.
Applications
• Cabling for rotating machines: motors, alternators, generators.
• Cabling for static machines: transformers, inductors, inverters, choppers.
• Shipbuilding and railway construction.
• Power cabinets.
Options
• Extra-flexible tin-plated copper core class 6 as per IEC 60228: contact us.
• Flexible or extra-flexible bare copper, silver-plated or nickel-plated copper core – class 5 or 6 as per IEC 60228: contact us.
• Without reinforcing braid (ref. SILICOUL® ST 6.6 KV): contact us.
• Varnished synthetic fibre reinforcing braid (ref. SILICOUL® RI 6.6 KV): contact us.
• Very high temperature fibre reinforcing braid: contact us.
• Outer flexible armour: > Galvanised steel braid (ref. SILICOUL® BG 6.6 KV): contact us. > Stainless steel braid (ref. SILICOUL® BI 6.6 KV): contact us.
• Multi-conductor cable made up of an assembly of several single conductor cables SILICOUL® 6.6 KV: contact us.
• Other colours: contact us.
• Other nominal cross-sections: contact us.
• Other options and/or combinations of the options outlined above: contact us.
1 • Flexible tin-plated copper core - class 5 as per IEC 60228.
2 • Semi-conductor tape(s).
3 • Insulation: Silicone rubber.
4 • Reinforcement: Coated synthetic fibre braid.
Nominal cross-section [mm2] |
Nominal stranding | Maximum linear resistance at 20 °C (Ω/km) | Nominal diameter [mm] |
Approximate linear weight [kg/km] |
---|---|---|---|---|
2.5 | 50 x 0.25 | 8.21 | 7.7 | 68.1 |
4 | 56 x 0.30 | 5.09 | 8.3 | 86.2 |
6 | 84 x 0.30 | 3.39 | 9.2 | 114 |
10 | 80 x 0.40 | 1.95 | 10.4 | 166 |
16 | 126 x 0.40 | 1.24 | 1 1.6 | 227 |
25 | 196 x 0.40 | 0.795 | 13.1 | 325 |
35 | 276 x 0.40 | 0.565 | 14.6 | 425 |
50 | 396 x 0.40 | 0.393 | 16.7 | 583 |
70 | 360 x 0.50 | 0.277 | 18.3 | 759 |
95 | 485 x 0.50 | 0.210 | 20.9 | 995 |
120 | 608 x 0.50 | 0.164 | 23.0 | 1262 |
150 | 756 x 0.50 | 0.132 | 25.3 | 1555 |
185 | 944 x 0.50 | 0.108 | 26.9 | 1904 |
240 | 1221 x 0.50 | 0.0817 | 30.7 | 2522 |
300 | 1525 x 0.50 | 0.0654 | 32.9 | 3059 |
400 | 2037 x 0.50 | 0.0495 | 37.2 | 3999 |
Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?
Ajouter à la liste de souhaits
Vous devez être connecté
Characteristics
• Continuous operating temperatures: -60 °C to +180 °C.
• Good resistance to thermal shock and UV.
• Excellent mechanical strength.
• Rated voltage: 6.6 kV.
• Test voltage: 15 kV.
Standard products
• Standard insulation colour: white.
• Standard reinforcing braid colour: grey.
Approvals - standards
• Lloyd’s Register approval certificates: compliance with the tests described as per standards
IEC 60228, IEC 60092-350/354/360,
IEC 60754-2, IEC 60332-1-1/2,
IEC 60332-3-22 category A and IEC 60331-11/21.
Applications
• Cabling for rotating machines: motors, alternators, generators.
• Cabling for static machines: transformers, inductors, inverters, choppers.
• Shipbuilding and railway construction.
• Power cabinets.
Options
• Extra-flexible tin-plated copper core class 6 as per IEC 60228: contact us.
• Flexible or extra-flexible bare copper, silver-plated or nickel-plated copper core – class 5 or 6 as per IEC 60228: contact us.
• Without reinforcing braid (ref. SILICOUL® ST 6.6 KV): contact us.
• Varnished synthetic fibre reinforcing braid (ref. SILICOUL® RI 6.6 KV): contact us.
• Very high temperature fibre reinforcing braid: contact us.
• Outer flexible armour: > Galvanised steel braid (ref. SILICOUL® BG 6.6 KV): contact us. > Stainless steel braid (ref. SILICOUL® BI 6.6 KV): contact us.
• Multi-conductor cable made up of an assembly of several single conductor cables SILICOUL® 6.6 KV: contact us.
• Other colours: contact us.
• Other nominal cross-sections: contact us.
• Other options and/or combinations of the options outlined above: contact us.
1 • Flexible tin-plated copper core - class 5 as per IEC 60228.
2 • Semi-conductor tape(s).
3 • Insulation: Silicone rubber.
4 • Reinforcement: Coated synthetic fibre braid.
Nominal cross-section [mm2] |
Nominal stranding | Maximum linear resistance at 20 °C (Ω/km) | Nominal diameter [mm] |
Approximate linear weight [kg/km] |
---|---|---|---|---|
2.5 | 50 x 0.25 | 8.21 | 7.7 | 68.1 |
4 | 56 x 0.30 | 5.09 | 8.3 | 86.2 |
6 | 84 x 0.30 | 3.39 | 9.2 | 114 |
10 | 80 x 0.40 | 1.95 | 10.4 | 166 |
16 | 126 x 0.40 | 1.24 | 1 1.6 | 227 |
25 | 196 x 0.40 | 0.795 | 13.1 | 325 |
35 | 276 x 0.40 | 0.565 | 14.6 | 425 |
50 | 396 x 0.40 | 0.393 | 16.7 | 583 |
70 | 360 x 0.50 | 0.277 | 18.3 | 759 |
95 | 485 x 0.50 | 0.210 | 20.9 | 995 |
120 | 608 x 0.50 | 0.164 | 23.0 | 1262 |
150 | 756 x 0.50 | 0.132 | 25.3 | 1555 |
185 | 944 x 0.50 | 0.108 | 26.9 | 1904 |
240 | 1221 x 0.50 | 0.0817 | 30.7 | 2522 |
300 | 1525 x 0.50 | 0.0654 | 32.9 | 3059 |
400 | 2037 x 0.50 | 0.0495 | 37.2 | 3999 |