Transformateurs actuels pour appareils de commutation - SVA170
  • Transformateurs actuels pour appareils de commutation - SVA170

Les photos sont à titre informatif uniquement. Voir les spécifications du produit

please use latin characters

Fabricant: ELEQ

Transformateurs actuels pour appareils de commutation - SVA170

The SVA170 is specially designed for application in medium voltage installations as Ring Main Units. This cast measuring transformer is cost effective and very reliable. Multi-core and multi ratio types are available in measuring and protection classes.


Environmental conditionss
This product is designed to be safe under the following conditions:
Location: Indeoor use
Ambient temperature: -5°C .. +40°C
Relative humidity: 5% .. 85%, non condensing
Protection drgree IP20
Suitable for: Cables, bus-bar
Application conditions
Standard: IEC 60044-1
Rated short-time thermal current(lth) 60 x In/1s
Continuous thermal current (lth) 100%
Rated insulation level: 0,72/3/-kv
Rated frequency: 50/60Hz
Class of insulation: E
Primary current 30-1000A
Primaty windows dimensions: Ø 110mm
Secondary terminal Screw terminals (max. 2Nm)
Wire diameter max. 6mm² solid max 4mm² stranded


 

Ratio Class Burden Articele number
100/1A 10P10 2VA 106532

Wiring diagram

Przekładniki prądowe do rozdzielnic - SVA170  schemat podłączenia

Przekładniki prądowe do rozdzielnic - SVA170 wentylatory

Envoyez une demande

Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?

Nous contacter
DEMANDEZ LE PRODUIT close
Merci d'avoir envoyé votre message. Nous vous répondrons dans les plus brefs délais.
DEMANDEZ LE PRODUIT close
Feuilleter

Ajouter à la liste de souhaits

Vous devez être connecté

The SVA170 is specially designed for application in medium voltage installations as Ring Main Units. This cast measuring transformer is cost effective and very reliable. Multi-core and multi ratio types are available in measuring and protection classes.


Environmental conditionss
This product is designed to be safe under the following conditions:
Location: Indeoor use
Ambient temperature: -5°C .. +40°C
Relative humidity: 5% .. 85%, non condensing
Protection drgree IP20
Suitable for: Cables, bus-bar
Application conditions
Standard: IEC 60044-1
Rated short-time thermal current(lth) 60 x In/1s
Continuous thermal current (lth) 100%
Rated insulation level: 0,72/3/-kv
Rated frequency: 50/60Hz
Class of insulation: E
Primary current 30-1000A
Primaty windows dimensions: Ø 110mm
Secondary terminal Screw terminals (max. 2Nm)
Wire diameter max. 6mm² solid max 4mm² stranded


 

Ratio Class Burden Articele number
100/1A 10P10 2VA 106532

Wiring diagram

Przekładniki prądowe do rozdzielnic - SVA170  schemat podłączenia

Przekładniki prądowe do rozdzielnic - SVA170 wentylatory